59500 Turbine Low Flow Sensor

www.hamlin.com
59500 Turbine Low Flow Sensor
Features
•
•
•
•
•
•
Low cost flow sensor
FDA & NSF61 approved materials
Suitable for potable water
Integral connector
Custom tube fittings available
Custom harnesses available
Benefits
Applications
• No standby power required
• Hermetically sealed contacts
• Robust construction
•
•
•
•
•
Water usage
Appliances
Residential monitoring
Commercial
Industrial
APPLICATION NOTE
Fluid entering the sensor passes through an internal turbine causing it to rotate at a speed proportional to the fluid velocity.A magnet integrated into the turbine actuates reed
switch contacts each revolution of the turbine.The resulting output frequency is directly proportional to the volumetric flow through the sensor.
DIMENSIONS (in) mm
Sensor with optional 1/4” Barbed Tube Fittings
(1.54)
39,1
(.50)
12,7
(3.68)
93,5
(1.28)
32,5
(.37)
9,3
(.80)
20,3
(x.83)
21,0
(1.30)
33,0
x1/4” Barbed Tube Fittings
SPECIFICATIONS
Electrical
Physical
Switch Type
Normally open
Contact rating
Power
Voltage
Current
Resistance
W - max.
Materials
10
Switching
Vdc - max.
200
Breakdown
Vdc - max.
250
Temperature range
Housing
PPE
Turbine
POM
Pivot
oC
0 -70
Stainless steel
Switching
A - max.
0.5
Pressure
PSI - max
180
Carry
A - max.
0.8
Accuracy
+
5%
Contact
h - max.
0.250
Durability
Gallons
100,000
Insulation
h - max.
1010
Min. flow rate
GPM
0.20
Mating connector
MolexSL
50-57-9402
CUSTOMER OPTIONS - Tube fittings
TABLE 1
Select Option
A Barbed Tube Fitting
B Rigid Tube Fitting
ORDERING INFORMATION
59036
59500
I
X
T
00
0
Series 59500
Fittings
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
Tel:
Tel:
Tel:
Tel:
Table 1
+1 920 648 3000 • Fax: +1 920 648 3001 • Email: [email protected]
+44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: [email protected]
+49 (0) 6142 923920 • Fax: +49 (0) 6142 923921 • Email: [email protected]
+33(0) 1 6047 3000 • Fax: +33(0) 1 6015 9136 • Email: [email protected]
Issue No: 2 Date: 01.07.07 DCR B5306
For details on chemical resistance please contact Hamlin
INFORMATION PROVIDED ON THIS DATA SHEET IS PROVIDED FOR INFORMATION
PURPOSES ONLY AND SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY
PARTICULAR PURPOSE. Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by providing information specific
to any particular application. HAMLIN disclaims any and all liability whatsoever for any
purchaser’s reliance upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.