www.hamlin.com 59025 Firecracker Features and Benefits File E61760(N) Actuator Sensor Features Benefits Applications • 2 part magnetically operated proximity sensor • UL recognised • Choice of normally open, normally closed or change over contacts • Customer defined sensitivity • Choice of cable length and connector • Quick and easy to install • No standby power requirement • Operates through non-ferrous materials such as wood, plastic or aluminium • Hermetically sealed, magnetically operated contacts continue to operate long after optical and other technologies fail due to contamination • • • • Position and limit sensing Security Level sensing Linear actuators DIMENSIONS (in) mm A Max B Max C NOM. 57025 (.245) 6,22 (1.000) 25,40 - 59025 (.245) 6,22 (1.000) 25,40 Table 3 ± (.393) 10,00 CUSTOMER OPTIONS - Switching Specifications Form A Normally Open Power Watt - max. Switching Vdc - max. Breakdown Normally Open High Voltage Change Over Normally Closed 1 2 3 4 10 10 5 5 200 300 175 175 Vdc - min. 250 450 200 200 A - max. 0.5 0.5 0.25 0.25 Carry A - max. 1.2 1.5 1.5 1.5 Contact, Initial Ω - max. 0.2 0.2 0.2 0.2 Insulation Ω - min. 1010 1010 109 109 Capacitance Contact pF - typ. 0.3 0.2 0.3 0.3 Temperature Operating °C -40 to +105 -20 to +105 -40 to +105 -40 to +105 Storage °C -65 to +105 -65 to +105 -65 to +105 -65 to +105 Operate ms - max. 1.0 1.0 3.0 3.0 Release ms - max. 1.0 1.0 3.0 3.0 Shock 11ms 1⁄2 sine G - max. 100 100 50 50 Vibration 50-2000 Hz G - max. 30 30 30 30 TABLE 1 Contact Type Switch Type Voltage Current Switching Resistance Time CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification TABLE 2 TABLE 3 Sensitivity Options:Activate Distances are approximate using Hamlin 57025 actuator as illustrated Switch AT before modification Select Option Switch Type 1 2 3 4 Normally Open High Voltage Change Over Normally Closed S Pull In AT Range 12-18 15-20 Activate Distance d (in) mm (.315) 8.0 (.276) 7.0 TABLE 4 Termination Options:- Cable Type:- 24 AWG 7/32 PVC 105oC UL1430/UL1569 SELECT OPTION Standard Lengths SELECT OPTION T Pull In AT Range 17-23 20-25 Activate Distance d (in) mm (.236) 6.0 (.216) 5.5 U Pull In AT Range 22-28 25-30 Activate Pull In Distance AT d Range (in) mm (.197) 27-33 5.0 V Activate Distance d (in) mm (.157) 4.0 (.177) 4.5 CABLE LENGTH (in) mm 01 (3.94 )100 02 (11.81) 300 03 (19,69) 500 04 (29,53) 750 05 DESCRIPTION (2 WIRE VERSIONS ILLUSTRATED) A Tinned leads (3.8±0.76)mm F Untinned leads (6.4±0.76)mm (39,37)1000 ORDERING INFORMATION 59025 59036 N.B. 57025 actuator sold separately Series 59025 Switch Type Sensitivity Hamlin USA UK Hamlin Germany Hamectrol France Issue No.: 5 Tel: Tel: Tel: Tel: DCR No.: B8163 Cable Length Table 1 Table 2 Table 32 Termination Table 43 +1 920 648 3000 • Fax: +1 920 648 3001 • Email: [email protected] Hamlin +44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: [email protected] +49 (0) 6142 923920 • Fax: +49 (0) 6142 923921 • Email: [email protected] +33 (0) 1 6047 3000 • Fax: +33 (0) 1 6015 9136 • Email: [email protected] Issue: Flash Du Date: 9/26/2011 22 X T X XX X DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE. Product performance may be affected by the application to which the product is put. Upon request, HAMLIN will assist purchasers by providing information specific to any particular application. HAMLIN disclaims any and all liability whatsoever for any purchaser’s reliance upon the information contained on this data sheet without further consultation with authorised representatives of HAMLIN.