Specifications - Grayhill, Inc.

Standard Keypads
SERIES 84S
Sealed
FEATURES
• Waterproof Silicone Rubber
• Easily Customized Legends
• Audible, Tactile Contacts
• Low Contact Resistance
• Optional RFI/EMI Shielding
• 3,000,000 Operations per Button
Keyboards and Keypads
DIMENSIONS
CIRCUITRY
In inches (and millimeters)
1 Button Module
#4-40 MTG. STUD,
2 PLACES (ALSO
SERVES AS
.313
TERMINALS)
(7,95)
1.125 ± .020
(28,58 ± 0,51)
.562 (14,27)
1.125 ± .020
(28,58 ± 0,51)
.500
(12,7)
MTG.
STUD
MTG.
STUD
.490
(12,45) SQ.
.500
(12,7)
LABEL
.562 (14,27)
.313
(7,95)
.500 (12,7)
.366 (9,30) SQ.
BUTTON AREA
.270 (6,86)
SINGLE THROW,
NORMALLY OPEN
.362 ± .015
(9,19 ± 0,38)
Note: Mounting studs serve as terminals.
Unless otherwise noted, linear dimension tolerances are ± .010 (0,25)
3x4 Keyboard
Matrix Output
.750 (19,05) 3 EQ. SPS.
TOL. NON-ACCUM.
3.100 ± .020
(78,74 ± 0,51)
.425
(10,80)
.100 (2,54) TYP.
.525 (13,34)
SWITCH POSITION
IDENTIFICATION
1
2
3
4
5
6
7
8
9
10
11
12
.490
(12,45)
SQ.
.025 ± .002
(0,64 ± 0,05) SQ.
TERMINAL
PINS
LABEL
.337 ± .015
(8,56 ± 0,38)
.267 ± .015
(6,78 ± 0,38)
.425 (10,80)
.750 (19,05) 2 EQ. SPS.
TOL. NON-ACCUM.
.366 (9,30) SQ.
BUTTON AREA
2.350 ± .020
(59,69 ± 0,51)
Single Pole/Common Bus
.350
(8,89)
#6-32 MTG
STUD
4 PLACES
#6-32 MTG
STUD
4 PLACES
1.500
.750 (38,1)
(19,05)
1.500
.750 (38,1)
(19,05)
LABEL
.800
(20,32)
1.650 (41,91)
.500 (12,7)
.270 (6,86)
.350
(8,89)
.800
(20,32)
1.650 (41,91)
.100 (2,54) REF. TERMINAL
PIN HEADER
.100 (2,54) REF. TERMINAL
PIN HEADER
TERMINAL PIN
IDENTIFICATION
TERMINAL PIN
IDENTIFICATION
A B C D E F G
.098 (2,49) REF. TERMINAL
PIN HEADER
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
.100 (2,54) TYP.
.225 (5,72)
A H B J C K D L E M F N G
.098 (2,49) REF. TERMINAL
PIN HEADER
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Keypads
11
Standard Keypads
DIMENSIONS
In inches (and millimeters)
4x4 Keyboard
Matrix Output
.750 (19,05) 3 EQ. SPS.
TOL. NON-ACCUM.
3.100 ± .020
(78,74 ± 0,51)
.425
(10,80)
1
2
3
4
5
6
7
8
9
10
11
12
13
.025 ± .002
(0,64 ± 0,05) SQ.
TERMINAL
.100
PINS
(2,54)
TYP.
.490
(12,45)
SQ.
2.250
(57,15)
1.125
(28,58)
.775
(19,69)
.750 (19,05) 3 EQ. SPS.
TOL. NON-ACCUM.
.500 (12,7)
1.500
(38,1)
.100
(2,54)
TYP.
2.250
(57,15)
1.125
(28,58)
.425
(10,80)
.310 (7,87)
1.500
(38,1)
LABEL
2.120
(53,85)
LABEL
2.120 (53,85)
.270 (6,86)
3.100 ± .020
(78,74 ± 0,51)
#6-32 MTG
STUD
6 PLACES
.750
(19,05)
.800
(20,32)
.425
(10,80)
.310
(7,87)
.098 (2,49) REF.
TERMINAL
PIN HEADER
.100 (2,54) REF.
TERMINAL
PIN HEADER
.098 (2,49) REF.
TERMINAL
PIN HEADER
TERMINAL PIN
IDENTIFICATION
F
E
D
B
C
A
G
H
.100 (2,54) REF.
TERMINAL
PIN HEADER
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
TERMINAL PIN
IDENTIFICATION
CODE AND TRUTH TABLES
Dots in the chart indicate connected terminals when switch is closed. Terminals are identified on the keyboard.
12 Button Keypads
1
2
3
4
5
6
7
8
9
10
11
12
Matrix
•
•
•
•
•
•
•
•
•
•
• •
•
•
•
Single Pole/Common Bus
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• •
••
C B A G F E D E C B F D A N K H M L J G
TERMINAL LOCATION
16 Button Keypads
4x4
BUTTON LOCATION
CODES
3x4
BUTTON LOCATION
Keyboards and Keypads
.337 ± .015
(8,56 ± 0,38)
.267 ± .015
(6,78 ± 0,38)
.425 (10,80)
.366 (9,30) SQ.
BUTTON AREA
.490 (12,45)
#6-32 MTG
STUD
6 PLACES
.750
(19,05)
16
15
14
Single Pole/Common Bus
.490 (12,45)
SWITCH POSITION
IDENTIFICATION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CODES
Single Pole/Common Bus
Matrix
•
•
•
•
•
•
•
•
•
•
• •
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• •
••
A B C D E F GH D B A C H F E G K M L J P R Q N S
TERMINAL LOCATION
SPECIFICATIONS
Rating Criteria
Rating at 24 Vdc: d10 milliamps resistive
Contact Bounce: 4 milliseconds maximum
at make; 10 milliseconds at break
Contact Resistance: MOS, TTL, and DTL
compatible. (10 ohms maximum)
Life Expectancy: 3 million operations/button
Insulation Resistance: 1,000 megohms
Operating Features
Pre-Travel: .030 inches minimum
Operating Temperature: -55°C to 85°C
Keypads
12
Operating Force: 20 ± 4 ounces
Humidity: 0 to 98% (no condensation)
Minimum Push Out Force Per Pin: 5 pounds
Materials and Finishes
Terminal Pins: Copper alloy CDA 725,
solder-plated
PC Board: FR-4 glass cloth epoxy
Contact Dome: Stainless steel, selectively
gold-plated
Dome Retainer/Rear Seal Sheet: Polyester
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
Mounting Studs: Phosphor bronze
Optional Hex Nut: Stainless steel, passivated
Optional EMI Shield: Aluminum foil
Keypad: Silicone rubber
Buttons: ABS Cycolac, grade FR15U
Shielding Effectiveness
Results shown are typical for a standard Grayhill
Series 84S Keyboard. A conductive gasket will
generally increase the shielding, depending on
the size and shape of the gasket and its material.
Data derived for E-Field Radiation.
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Standard Keypads
dB
100
Frequency Rating
MHz
in dB
0.1
66.2
10
94.8
100
90.5
400
64.2
800
42.3
2,000
40.5
6,000
33.1
10,000
34.4
18,000
37.0
80
60
40
20
0
0.1
receiving equipment. A signal generator
provided the frequency source that was radiated
from the transmitting antenna to the enclosed
receiving antenna. The spacing between
antennas was maintained constant throughout
the frequency range. The effectiveness rating
is determined by establishing a reference
reading without obstruction between the two
antennas and determining the difference
between that reading and the test setup reading.
SHIELDING EFFECTIVENESS OF 84S-AC2
10
100
400
800
2000
6000 10000 18000
MHz
Represents shielding effectiveness
greater than or equal to line.
STANDARD LEGENDS
Available through Grayhill Distributors
To order one of the configurations below, use the dash number shown here; select the
keypad size and code, and order the part number with the appropriate legend dash number.
The buttons in these keypads can be removed, and reinserted in any configuration.
ABC
DEF
ABC
DEF
1
2
3
1
2
3
D
GHI
JKL
MNO
GHI
JKL
MNO
4
5
6
4
5
6
9
E
PRS
TUV
WXY
PRS
TUV
WXY
7
8
9
7
8
9
B
F
1
2
3
1
2
3
C
4
5
6
4
5
6
7
8
9
7
8
A
0
0
-112
-014
OPER
OPER
0
0
-113
A
B
C
D
-016
CUSTOM LEGENDS
MENU
PROGRAM
MODE
EDIT
SET
LOCK
INPUT
HOLD
RUN
FWD
REV
STOP
CLEAR
CANCEL
ON
OFF
HEADER CONNECTORS
Library of Legends
Adding Color
Grayhill maintains a legend library which
contains the most often requested special
legends and many unusual ones. If the legend
is in the library, the cost to utilize this legend in
your keypad configuration is minimal. If the
legend is not available, Grayhill can list the
charges required to add your legend to the
library. In this manner, new legends are added
on a periodic basis. Custom legends to fit your
unique requirements may not be as expensive
as you think, contact Grayhill.
Use colored buttons to segregate button
groupings or to provide originality. Available in
black legends on white or yellow buttons, or in
white legends on black, green, red or blue
buttons. Two popular combinations, black on
white and white on black, are available from
Grayhill stock. Delivery time will increase for
other color combinations.
A
B
C
D
E
F
ORDERING INFORMATION
Compatible with: Samtec, Inc. Header Series
BCS, BSW, CES, ESW, ESQ, SLW, SSW, SSQ,
IDSS and IDSD or equivalent.
Grayhill Series Number
Shielded or Non-Shielded Option
S = Shielded; SN = Non-Shielded
Size Option: A = 3x4; B = 4x4; C = 1 Button
Circuitry Option (B2 and C2 not applicable to 1 button)
B2 = Matrix in-line pins
C2 = Single pole/common bus, in-line pins
C3 = 1 Button, SPST–N.O., non-shielded only
Available from your local Grayhill Distributor.
For prices and discounts, contact a local Sales
Office, an authorized local Distributor or Grayhill.
84S-AC2-113-N
Mounting Nut Option
N = Provided with hex nuts for mounting; Blank = Nuts not provided
Standard Legend Choices
3x4 Size: -112 or -113; -000, No buttons; -101, Blank Buttons
4x4 Size: -014 or -016; -000, No buttons; -001, Blank Buttons
1 Button Size: -001, No legend, white button
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Keypads
13
Keyboards and Keypads
Note:
When measured in actual equipment, shielding
effectiveness is determined by many factors.
This method accurately represents the shielding
effectiveness of the Grayhill Series 84S under
ideal test conditions.
Test Method:
Measurements were made with the keyboard
mounted to a brass plate, which in turn was
mounted to a shielded enclosure containing the