Type VMN Voltage Monitoring Resistor Networks Transient Tolerant New Voltage Dividers for Industrial Power Quality and Power Consumption Metering Applications Ratio Tolerance of 0.1% or 0.02%, Ratio TC of 10 ppm/°C or 5 ppm/°C The Type VMN Transient Tolerant Voltage Monitoring Networks are designed for use in the voltage measurement circuits of Power Quality Monitoring Equipment, Kilowatt-Hour Meters, and other Power and Energy Measurement Equipment, where precision electrical service voltage monitoring is required. The VMN Networks are manufactured with Tetrinox®, Caddock’s Ultra-Stable Low-TC Resistance Film System. The Tetrinox film system, combined with Caddock’s Ceramic Sandwich Resistor Network construction, provides outstanding long-term stability in industrial applications with electrical surges, transient conditions, and high humidity exposure. For Custom Type VMN Voltage Monitoring Networks developed to meet your program requirements, contact Applications Engineering at Caddock. 7 8 1 2 Resistance Normal Operating Voltage (AC rms) Maximum Operating Voltage (AC rms) Voltage Divider Ratio R1 R2 Total Resistance (R1 + R2) VMN4-2M-400 450 Volts 600 Volts 400 : 1 1.995 Meg 5K VMN4-2M-400-5 450 Volts 600 Volts 400 : 1 1.995 Meg 5K VMN4-5M-500 700 Volts 900 Volts 500 : 1 4.990 Meg VMN4-5M-500-5 700 Volts 900 Volts 500 : 1 4.990 Meg Part Number 5 4 3 6 Ratio Tol. Ratio T.C. Ratio V.C. Overload Voltage Rating Impulse (Surge) Voltage 2 Meg 0.1% 10 ppm/°C 0.03 ppm/V 1,000 Volts 10 kV 2 Meg 0.02% 5 ppm/°C 0.03 ppm/V 1,000 Volts 10 kV 10 K 5 Meg 0.1% 10 ppm/°C 0.02 ppm/V 1,500 Volts 10 kV 10 K 5 Meg 0.02% 5 ppm/°C 0.02 ppm/V 1,500 Volts 10 kV Specifications 1 Ratio: (R1+R2) : R2 (Voltage Divider Ratio) 2 Ratio Tolerance: measured at 100 Volts at +23°C ambient 3 Ratio T.C.: measured at -40°C and +85°C, ref. to +25°C 4 Ratio V.C.: measured at 100 Volts DC and 600 Volts DC 1.000 ±.020 (25.40 ±.51) Absolute T.C.: 30 ppm/°C, measured at -40°C and +85°C, referenced to +25°C Ratio Stability: 7 Normal Operating Voltage applied to R1 and R2 connected in series at +85°C. Change in Ratio after 2,000 hours is ±0.02% maximum. 8 Maximum Operating Voltage applied to R1 and R2 connected in series at +85°C. Change in Ratio after 2,000 hrs is ±0.04% maximum. 5 Overload Voltage and Stability: Overload Voltage applied for 10 seconds to R1 and R2 connected in series at +25°C. Change in Ratio is 0.01% maximum. 6 Impulse Voltage and Stability: 1.2/50 microsecond waveform. The impulse voltage wave shape shall have a rise time of 1.2 microseconds to 90% of the impulse voltage peak, followed by a fall time of 50 microseconds to 50% of the impulse voltage peak. Impulse applied to Pin 1 (with R1 and R2 connected in series), with Pin 5 held near ground. After 20 pulses applied, the Change in Ratio is 0.01% maximum. .510 ±.020 (12.95 ±.51) Seated Height CADDOCK VMN4-5M-500-5 1432 Absolute Tolerance: ±1% .110 Max. (2.79) 6 D .050 (1.27) .100 (2.54) .600 (15.24) .700 (17.78) .020 ±.002 (0.51 ±.05) .900 (22.86) R1 1 2 See Lead Form Detail Note Lead Form Detail Note: The lead form detail provides interference in the circuit board hole to achieve a vertical mount of the device. Recommended circuit board hole is nominally 0.039 inch (1.00 mm). R2 3 4 .150 ±.040 (3.81 ±1.02) 5 Isolation Dimension D: Minimum distance between metal portions of Pins 2 and 3 is 0.414 inch (10.51 mm) Operating Temperature Range: -40°C to +85°C Applications Engineering and Sales 17271 North Umpqua Hwy. Roseburg, Oregon 97470-9422 Phone: (541) 496-0700 Fax: (541) 496-0408 © 2014 Caddock Electronics, Inc. e-mail: [email protected] • web: www.caddock.com For Caddock Distributors listed by country see caddock.com/contact/dist.html Corporate Office 1717 Chicago Avenue Riverside, California 92507-2364 Phone: (951) 788-1700 Fax: (951) 369-1151 IL-428.1014