Specification BR-782

Offshore and
Marine Shipboard
Cables
IEEE 1580 Type P
MOR Polyrad XT-125 Multi Conductor
®
®
Specification BR-782
MOR® Polyrad® XT-125 Flexible Marine Type P
Irradiated Cross-Linked Polyolefin Multi Conductor
Rated 600/1000 Volts (AC or DC)
For Use on Oil Rigs-Shipboard-Apparatus
TABLE OF CONTENTS
SECTION
SUBJECT
PAGE
I.
SCOPE ..............................................................................................................................1
II.
APPLICABLE DOCUMENTS ...............................................................................................1
III.
CONDUCTOR .....................................................................................................................2
IV.
SEPARATOR .....................................................................................................................2
V.
INSULATION ...................................................................................................................2
A. Physical Properties ....................................................................................................2
B. Electrical Properties ...................................................................................................3
C. Qualification Testing ..................................................................................................3
1. Tension Set ..........................................................................................................3
2. Ozone Resistance .................................................................................................3
3. Flammability Requirements .................................................................................3
4. Corrosion Tests ....................................................................................................3
a) Copper Mirror ...............................................................................................3
b) Acid Gas Detection.......................................................................................3
5. Oil Resistance ......................................................................................................4
6. Smoke Emission ...................................................................................................4
7. Abrasion Resistance ............................................................................................4
8. Crush Resistance..................................................................................................4
9. MC-HL Crush and Impact .....................................................................................4
VI.
CONDUCTOR IDENTIFICATION .........................................................................................5
VII.
CABLING ...........................................................................................................................5
VIII.
OVERALL JACKET/OVERALL SHEATH ..............................................................................5
IX.
FINISHED CABLE TEST .....................................................................................................6
X.
ARMOR .............................................................................................................................6
XI.
CABLE IDENTIFICATION ...................................................................................................6
XII.
REEL MARKINGS ..............................................................................................................6
Revision 17
Date: 04/04/13
Phone (888) 593-3355 • Fax (800) 335-1270 • Int’l Phone +1 859 572 8000 • Int’l Fax + 1 859 572 8058
www.generalcable.com
INS-0148-R0413
Offshore and
Marine Shipboard
Cables
IEEE 1580 Type P
MOR Polyrad XT-125 Multi Conductor
®
®
Specification BR-782
MOR® Polyrad® XT-125 Flexible Marine Type P
Irradiated Cross-Linked Polyolefin Multi Conductor
Rated 600/1000 Volts (AC or DC)
For Use on Oil Rigs-Shipboard-Apparatus
I. Scope
This specification covers cables manufactured in accordance with IEEE Std 45/ IEEE Std 1580-2010. These Power and
Distribution, Signal, and Control cables are rated at 600/1000 volts AC or DC. They are manufactured with General Cable’s
MOR Polyrad XT-125 Type P Marine insulation, and a thermosetting irradiated cross-linked Polyolefin and Arctic-Grade,
Enhanced Mud Oil resistant, Chlorosulfonated Polyethylene jacket which have been designed for use on oil rigs, shipboard and
associated apparatus. An armor of aluminum or bronze and an overall sheath are also available at the option of the purchaser.
IEEE 1580 Type P cables should be designed, engineered and produced by cable manufacturers that have manufactured these
specific cables for a minimum of 15 years. These manufacturers should be actively involved in the standards organizations
that support the continued development, safety and quality of IEEE 1580 Type P cables.
II. Applicable Documents
The wire and cable manufactured under this specification shall be tested and inspected in accordance with the latest issues
of the following standards, as applicable or as modified herein:
1
ASTM B33
Tinned Soft or Annealed Copper Wire
ASTM D149
Test for Dielectric Breakdown Voltage and Dielectric Strength of Electrical Insulation
Materials at Commercial Power Frequencies
CSA C22.2 No. 245/ UL 1309
Marine Shipboard Cable
CSA C22.2 No. 38
RW 75 XLPE 600V
Standard for Thermoset Insulated Wires and Cables
CSA C22.2 No. 230 TC
Standard for Tray Cable
IEEE Std 45
IEEE Recommended Practice for Electrical Installation on Shipboard
IEEE Std 1580
IEEE Recommended Practice for use on Shipboard and Marine Fixed or Floating Platforms
IEEE Std 383
Type Test of Class 1E Electrical Cable, Field Splices & Connectors for Nuclear Power
Generating Stations
IEEE Std 1202
Standard for Flame Testing of Cables for use in Cable Tray in Industrial and Commercial
Occupancies
IEC-92-3
Electrical Installations in Ships, Part 3; Cables (Construction, Testing and Installation)
IEC 60332-3 A
Tests on Electric Cables Under Fire Conditions
ICEA S-95-658
ICEA/NEMA Standard for Non-shielded Power Cables Rated 2000 Volt or Less for
Distribution of Electrical Energy (NEMA WC 70)
NEK 606
Cables for offshore installations halogen-free and/or mud resistant
UL 44 XHHW
Standard for Rubber Insulated Wire & Cable
UL (UBVZ)
Shipboard Cable, Marine
Phone (888) 593-3355 • Fax (800) 335-1270 • Int’l Phone +1 859 572 8000 • Int’l Fax + 1 859 572 8058
www.generalcable.com
INS-0148-R0413
Offshore and
Marine Shipboard
Cables
IEEE 1580 Type P
MOR Polyrad XT-125 Multi Conductor
®
®
Specification BR-782
MOR® Polyrad® XT-125 Flexible Marine Type P
Irradiated Cross-Linked Polyolefin Multi Conductor
Rated 600/1000 Volts (AC or DC)
For Use on Oil Rigs-Shipboard-Apparatus
III. Conductor
Conductors shall be of soft annealed tinned copper per ASTM B33 and shall conform to requirements as listed in the
Dimensional Data section of the Type P data sheets.
IV. Separator
A suitable separator may be used if deemed necessary by the manufacturer.
V.
Insulation
The insulation shall be Polyrad® XT-125 Type P Marine, an irradiated cross-linked polyolefin, with a minimum average thickness as listed in the Dimensional Data section of the Type P data sheets. The insulated conductor shall meet the following
requirements:
A. Physical Properties
Unaged Requirement
Tensile Strength, Min. PSI
Elongation at rupture, Min. %
2000 Min.
250 Min.
Aged Requirements
After air oven 7 days @ 158°C ± 2°C
Tensile Strength (% of original)
Elongation (% of original)
90 Min.
55 Min.
After air oven 7 days @ 121°C ± 2°C
Tensile Strength (% of original)
Elongation (% of original)
90 Min.
90 Min.
Oxygen Bomb 7 days @ 80°C @ 300 PSI
Tensile Strength (% of original)
Elongation (% of original)
90 Min.
90 Min.
Air Bomb 42 hours @ 127°C 80 PSI
Tensile Strength (% of original)
Elongation (% of original)
90 Min.
90 Min.
Heat Distortion, 1 hour @ 200°C
Clause 4.3.6.1 CSA Std. C22.2 No. 0.3
Cold Bend, 120 hours @ -55°C
20% Max.
6 kV - 5 Min.
2
Phone (888) 593-3355 • Fax (800) 335-1270 • Int’l Phone +1 859 572 8000 • Int’l Fax + 1 859 572 8058
www.generalcable.com
INS-0148-R0413
Offshore and
Marine Shipboard
Cables
IEEE 1580 Type P
MOR Polyrad XT-125 Multi Conductor
®
®
Specification BR-782
MOR® Polyrad® XT-125 Flexible Marine Type P
Irradiated Cross-Linked Polyolefin Multi Conductor
Rated 600/1000 Volts (AC or DC)
For Use on Oil Rigs-Shipboard-Apparatus
B. Electrical Properties
Dielectric Strength per ASTM D-149
> 700 V/Mil
Insulation Resistance
> 5000 Megohms/m’ = 20,000
Insulation Resistance K
Accelerated Water Absorption
Gravimetric 7 days @ 70°C
5 MG/in2
Electrical SIC 24 hours @ 75°C
Increase in Capacitance
1 - 14 Days
7 - 14 Days
Stability Factor after 14 Days
C. Qualification Testing
1. Tension Set
Gauge marks are 4” apart.
6.0
4.0
1.5
.5
10% Maximum
2. Ozone Resistance
After 24 hours exposure to an ozone concentration of 0.03% by volume at 90°C ± 2°C, there shall be no insulation cracks.
3. Flammability Requirements
Insulated conductors shall pass the flame test described in ICEA S-19-81 and the VW-1 vertical flame test described in UL
Subject 44. The maximum afterburn after each flame application shall be no greater than 3 seconds.
All multi conductor cables insulated with Polyrad XT-125 Type P Marine insulation and jacketed with thermosetting
Chlorosulfonated Polyethylene shall meet the requirements of IEEE Standard 45, IEEE Standard 1580, IEEE Standard 1202
and IEC 60332-2A for flame tests.
4. Corrosion Tests
a) Copper Mirror: (Ref. ASTM 2671) A 0.4 gram sample of insulation is placed in the bottom of a 2 inch x 12 inch
test tube. A copper coated glass mirror shall be suspended 6 inches over the sample by a thin copper wire. The
lower two inches of the test tube shall be heated to 175°C for 16 hours.
Requirement: Remove less than 5% of the copper film.
b)
3
Acid Gas Detection: A 1.0 mg sample shall be heated to combustion in a closed quartz tube. The resulting gases
are drawn through a detector tube (MSA #91636) using a special air sampling pump manufactured by Mine
Safety Apparatus Company. The amount of acid gas is determined by measuring the length of the color change
in the detector tube.
Requirement: 220 PPM/MG typical.
Phone (888) 593-3355 • Fax (800) 335-1270 • Int’l Phone +1 859 572 8000 • Int’l Fax + 1 859 572 8058
www.generalcable.com
INS-0148-R0413
IEEE 1580 Type P
MOR Polyrad XT-125 Multi Conductor
Offshore and
Marine Shipboard
Cables
®
®
Specification BR-782
MOR® Polyrad® XT-125 Flexible Marine Type P
Irradiated Cross-Linked Polyolefin Multi Conductor
Rated 600/1000 Volts (AC or DC)
For Use on Oil Rigs-Shipboard-Apparatus
5. Oil Resistance
Hot Oil Swell Tests - Insulated wires are premeasured and immersed in a hot oil bath. After the required exposure time,
they are removed and measured for the amount of swell.
Requirement:
A. IRM 902 Oil
100 hours @ 150°C Max.
Max. % Swell 60
B. Diesel Oil
100 hours @ 60°C Max.
Max. % Swell 60
Note: When tested in accordance with AAR 589 (ASTM #2 Oil at 121°C for 18 hours), the retention of tensile and elongation shall be:
Tensile - 70% Minimum Elongation - 90% Minimum
6. Smoke Emission
The tests shall be performed in an N.B.S. Smoke Chamber using #12 AWG wire insulated with 45 mils of Polyrad XT
Marine. The procedures are per NFPA Standard 258 in the flaming (F) and non-flaming (N) modes.
Dm
T16
T.9Dm
(F) Flaming plus Radiant Furnace 485
1.20
7.15
(N) Non-flaming Radiant Furnace 203
10.3
25.7
Dm
T16
T.9 Dm
=
=
=
Max. Specified Optical Density
Time to reach critical Ds (Specified Optical Density)
Time to reach 90% of Dm
7. Abrasion Resistance
Rotating Scrap abrader (Ref. MIL-C-915) - A 24 inch specimen is draped over an 8 inch rotating drum with two (2) 90° vee
edge abrading tools 180° apart. Failure is detected by electrical contact between abrading tool and conductor. The cable
is weighted with a 450 gram weight.
Requirement: 2500 cycles minimum
8. Crush Resistance
A wire sample is placed between two (2) parallel flat plates and compressed until electrical contact is detected across
conductor to the plate.
Requirement: 7500 lbs. minimum
9. MC-HL Crush and Impact
Meets UL 2225 crush and impact requirements
4
Phone (888) 593-3355 • Fax (800) 335-1270 • Int’l Phone +1 859 572 8000 • Int’l Fax + 1 859 572 8058
www.generalcable.com
INS-0148-R0413
Offshore and
Marine Shipboard
Cables
IEEE 1580 Type P
MOR Polyrad XT-125 Multi Conductor
®
®
Specification BR-782
MOR® Polyrad® XT-125 Flexible Marine Type P
Irradiated Cross-Linked Polyolefin Multi Conductor
Rated 600/1000 Volts (AC or DC)
For Use on Oil Rigs-Shipboard-Apparatus
VI. Conductor Identification
Conductor identification shall be obtained by Method 1 of ICEA S-95-658, solid colors with tracer stripes when necessary.
VII. Cabling
Individual conductors shall be cabled together with a lay of 8 to 16 times the overall diameter of the cable layer. When
required, non-hygroscopic cable binder tape or cable fillers shall be used to maintain a concentric cross-section.
VIII. Arctic-Grade Overall Jacket/Overall Sheath
The arctic-grade overall jacket, and when required the arctic-grade overall sheath, will meet NEK 606 ester-based mud oil
resistant requirements and be black irradiated cross-linked Chlorosulfonated Polyethylene meeting the following requirements when tested in accordance with IEEE Standard 1580-2010.
Jacket & Overall Sheath
Physical Properties
Requirements Per
IEEE 1580-2010 Table 16
Material
General Cable
Type CP Jacket
Thermosetting
Thermosetting
Chlorosulfonated Polyethylene Chlorosulfonated Polyethylene
Physical Requirements
Unaged:
Tensile Strength, min. psi
Elongation at rupture, min. percent
Set, max. percent
1800
300
30
2200
350
12
Aging Requirements
After air oven at °C
Hours
Tensile Strength percent of unaged, min.
Elongation at rupture, percent of unaged, min.
121 ± 1
168
85
65
121 ± 1
168
100
90
After oil immersion at °C
Hours
Tensile Strength percent of unaged, min.
Elongation at rupture, percent of unaged, min.
121 ± 1
18
60
60
121 ± 1
18
90
90
Cold Bend, no cracks, °C (Note 1)
-40
-55
Cold Impact, °C (Note 1)
-40
-40
100
87
S-95-658
S-95-658
Mechanical water absorption, mg/in
2
ICEA Test Procedure reference
NOTE: (1)
For test procedures refer to CSA Standard C22.2, No. 38, Clause 6.4.7. The insulation system used for this test shall be representative of the
final product. Cable intended for arctic or severe cold application should be capable of passing both cold bend at -40°C and cold impact at -40°C.
5
Phone (888) 593-3355 • Fax (800) 335-1270 • Int’l Phone +1 859 572 8000 • Int’l Fax + 1 859 572 8058
www.generalcable.com
INS-0148-R0413
Offshore and
Marine Shipboard
Cables
IEEE 1580 Type P
MOR Polyrad XT-125 Multi Conductor
®
®
Specification BR-782
MOR® Polyrad® XT-125 Flexible Marine Type P
Irradiated Cross-Linked Polyolefin Multi Conductor
Rated 600/1000 Volts (AC or DC)
For Use on Oil Rigs-Shipboard-Apparatus
IX. Finished Cable Test
Each completed cable length shall be tested without immersion in water and successfully withstand a 5 minute AC potential
in accordance with Table 3-2 of ICEA S-95-658. In addition to the voltage withstand test described above, randomly selected
samples shall be tested in accordance with Part 6, ICEA S-95-658 and meet the requirements as stated in this specification.
X.
Armor
When specified, shall be in accordance with IEEE Standard 1580.
XI. Cable Identification
The surface of the cable shall be printed with the following minimum information at intervals not greater than two feet.
Where appropriate, additional print legend markings pertaining to (UL) Type TC, (UL) Type TC-ER, and/or (CSA) Type TC will
be included.
MOR® POLYRAD® XT-125 (UL) E85994 BR782 110C XX/C XXAWG OR TC-ER1 XHHW OR (CSA) 245/1309 FT4 –40C
600/1000V OR 600V RW75 XLPE TC2 OR IEC 60332.3A IEEE 1580 Type P or (ETL) 109229 YEAR OF MFG SEQUENTIAL
FOOTAGE MARK
1
- ER for 3 conductors or more, unarmored
2
CSA Listing - 600V RW75 XLPE TC for 14 AWG and larger, unarmored
XII. Reel Markings
Each reel to be shipped shall be marked to include the following information in addition to any other information specified by
the purchaser:
General Cable
MOR Polyrad XT-125 Type P Marine
Voltage Rating
Conductor Size & No. of Conductors
Footage on Reel
Month/Year of Manufacture
6
Phone (888) 593-3355 • Fax (800) 335-1270 • Int’l Phone +1 859 572 8000 • Int’l Fax + 1 859 572 8058
www.generalcable.com
INS-0148-R0413