Optoway XPS-2310W-CXX0G 1 *********************************************************************************************************************************************************************** XPS-2310W-CXX0G (RoHS Compliant) 10Gbps / CWDM XFP Single-Mode Optical Transceiver for 10GbE / 10GFC ********************************************************************************************************************************************************************** FEATURES DESCRIPTION z z z z z z z z XPS-2310W-CXX0G series transceiver is designed for single-mode fibre serial optical data communications such as 10G Ethernet 10GBASE-LR/LW and 10G Fibre Channel 1200-SM-LL-L. This module is designed for single mode fiber and operates at a nominal wavelength of CWDM wavelength. There are eighteen center wavelengths available from 1270 nm to 1610 nm, with each step 20 nm. A guaranteed minimum optical link budget of 11 dB is offered. The transceiver consists of two sections: The transmitter section consists of a directly modulated uncooled CWDM DFB laser, driver and signal conditioner. The receiver section incorporates a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and signal conditioner. The module is with the XFP 30-pin connector to allow hot plug capability. Integrated Tx and Rx signal conditioners provide high jitter-tolerance for full XFI compliance and no external reference clock required. The internally ac coupled high speed serial I/O simplifies interfacing to external circuitry. Only single 3.3V power supply is needed. The optical output can be disabled by LVTTL logic high-level input of TX_DIS. Loss of signal (RX_LOS) output is provided to indicate the loss of an input optical signal of receiver. A serial EEPROM in the transceiver allows the user to access transceiver digital diagnostic monitoring and configuration data via the 2-wire XFP Management Interface. This interface uses a single address, A0h, with a memory map divided into a lower and upper area. Basic digital diagnostic data is held in the lower area while specific data is held in a series of tables in the high memory area. z z z z z z z Support 9.95 Gbps to 10.5 Gbps Complaint with XFP MSA Compliant to IEEE 802.3ae 10GBASE-LR/LW Compliant to 10GFC 1200-SM-LL-L Compliant with XFI 10G Serial Electrical Interface Maximum Link Length of 10 km Uncooled 18-Wavelength CWDM DFB LD 2-Wire Interface for Integrated Digital Diagnostic Monitoring XFI Loopback Mode No reference Clock required Only Required +3.3 V Power Supply Power Consumption < 2 W RoHS Compliant -5 to 70oC Case Operating Temperature Duplex LC Connector APPLICATIONS z 10GBASE-LR at 10.3125 Gb/s z 10GBASE-LW at 9.953 Gb/s z 10GFC at 10.51875 Gb/s LASER SAFETY This single-mode transceiver is a Class 1 laser product. It complies with IEC-60825 and FDA 21 CFR 1040.10 and 1040.11. The transceiver must be operated within the specified temperature and voltage limits. The optical ports of the module shall be terminated with an optical connector or with a dust plug. ORDER INFORMATION P/No. Bit Rate (Gb/s) 10GBASE XPS-2310W-CXX0G 9.95 – 10.52 LR/LW Power Budget (dB) > 11 Wavelength (nm) Package Case Temp (oC) RoHS Compliant CWDM* XFP with DMI -5 to 70 Yes Max. (nm) 1457.5 1477.5 1497.5 1517.5 1537.5 1557.5 1577.5 1597.5 1617.5 Label CWDM* Wavelength (0 to 70oC) Central Wavelength -C270 -C290 -C310 -C330 -C350 -C370 -C390 -C410 -C430 Min. (nm) 1264.5 1284.5 1304.5 1324.5 1344.5 1364.5 1384.5 1404.5 1424.5 Typ. (nm) 1270 1290 1310 1330 1350 1370 1390 1410 1430 Max. (nm) 1277.5 1297.5 1317.5 1337.5 1357.5 1377.5 1397.5 1417.5 1437.5 Label C27 C29 C31 C33 C35 C37 C39 C41 C43 Central Wavelength -C450 -C470 -C490 -C510 -C530 -C550 -C570 -C590 -C610 Min. (nm) 1444.5 1464.5 1484.5 1504.5 1524.5 1544.5 1564.5 1584.5 1604.5 Typ. (nm) 1450 1470 1490 1510 1530 1550 1570 1590 1610 C45 C47 C49 C51 C53 C55 C57 C59 C61 CWDM*: 18 Wavelengths from 1270 nm to 1610 nm, each step 20 nm. ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 2/1/2008 V1.0 Optoway XPS-2310W-CXX0G 2 *********************************************************************************************************************************************************************** Absolute Maximum Ratings Parameter Storage Temperature Operating Case Temperature Relative Humidity Power Supply Voltage Symbol Tstg Topr RH VCC3 Min -40 -5 0 0 Max 85 70 85 3.6 Units o C o C % V Min 3.13 Typ 3.3 Max 3.47 550 2 70 10.52 Notes Non condensing Recommended Operating Conditions Parameter Power Supply Voltage Power Supply Current (@3.3V) Power Dissipation Operating Case Temperature Data Rate Symbol VCC3 ICC3 PD Topr -5 9.95 Units / Notes V mA W o C Gb/s Transmitter Optical Specifications (Topr= -5 to 70oC, Vcc3 = 3.3V ±5%) Parameter Average Launch Power Optical Modulation Amplitude Extinction Ratio Output Center Wavelength Output Spectrum Width Side Mode Suppression Ratio Relative Intensity Noise Optical Eye Mask Average Launch Power of OFF Transmitter Symbol Min Typ Max Units Po, Avg -3 1 dBm Po, OMA -5.0 dBm ER 3.5 dB λc –5.5 λc λc +7.5 λc nm 1 nm σλ SMSR 30 dB RIN -128 dB/Hz Compliant with IEEE 802.3ae 10GBASE-L XFP MSA -30 dBm Notes 1 2 -20 dB width 1. Output power is power coupled into a 9/125 μm single-mode fiber. 2. ITU-T G.694.2 CWDM wavelength from 1270 nm to 1610 nm, each step 20 nm. Receiver Optical Specifications (Topr= -5 to 70oC, Vcc3 = 3.3V ±5%) Parameter Sensitivity Receiver Overload LOS -- Deasserted LOS -- Asserted LOS -- Hysteresis Wavelength of Operation Optical Return Loss Symbol Sen1 PMAX LOSD LOSA λc ORL Min Typ 0.5 ---26 1 1260 --------- Max -14 -15 --5 1620 -12 Units dBm dBm dBm dBm dB nm dB Notes 3 Transition: low to high Transition: high to low 3. Average received power; BER < 10-12 and PRBS 231-1. ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 2/1/2008 V1.0 Optoway XPS-2310W-CXX0G 3 *********************************************************************************************************************************************************************** Electrical Characteristics Parameter Symbol High-Speed Signal (CML) Interface Specification Input Data Rate Differential Input Impedance Rin Differential Data Input Amplitude Output Data Rate Differential Output Impedance Rout Differential Data Output Amplitude Low-Speed Signal (LVTTL) Interface Specification Input High Voltage Input Low Voltage Output High Voltage Output Low Voltage Reference Clock (LVPECL) Interface Specification Min Typ Max Units 9.95 10.3125 100 10.52 Gb/s Ω 820 10.52 mVpp Gb/s Ω 1, Internally AC coupled 340 850 mVpp 1, Internally AC coupled 2.0 GND 2.4 GND Vcc 0.8 Vcc 0.5 V V V V 120 9.95 10.3125 100 Notes No reference clock 1. The differential input and output amplitudes are per XFP MSA mask at points B’ and C’. Transceiver Timing Characteristics Parameter TX_DIS Assert Time TX_DIS Negate Time Time to Initialize Interrupt Assert Delay Interrupt Negate Delay P_Down/PST Assert Delay P_Down Nagate Delay Mod_NR Assert Delay Mod_NR Negate Delay Mod_Desel Assert Time Mod_Desel De-Assert Time P_Down Reset Time RX_LOS Assert Delay RX_LOS Negate Delay Serial ID Clock Rate Symbol t_off t_on t_init interrupt_on interrupt_off P_Down/RST_on P_Down/RST_off Mod_nr_on Mod_nr_off T_Mod_Desel T_Mod_Sel T_reset T_Los_on T_Los_off fSCL Min Typ Max 10 2 300 200 500 100 300 1 1 2 2 10 0 100 100 400 Units μs ms ms ms μs μs ms ms ms ms ms μs μs μs kHz Notes ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 2/1/2008 V1.0 Optoway XPS-2310W-CXX0G 4 *********************************************************************************************************************************************************************** Management Interface The structure of the memory map is shown in Figure 1, which is accessible over a 2-wire serial interface at the 8-bit address 1010000X (A0h). The normal 256 byte I2C address space is divided into low and upper blocks of 128 Bytes. The lower block of 128 Bytes is always directly available and is used for the diagnostics and control function. Multiple blocks of memories are available in the upper 128 Bytes of the address space. These are individually addressed through a table select Byte which the user enters into a location in the lower address space. Thus, there is a total available address space of 128*256 = 32 Kbytes in this upper memory space. The contents of Table 01h are listed in Table 1 below. Please refer SFF INF-8077i (Revision 4.5) for detailed information. Figure 1. 2-wire Serial Digital Diagnostic Memory Map Data Address 96 ~ 97 98 ~ 99 100 ~ 101 102 ~ 103 104 ~ 105 106 ~ 107 Table 1 Monitoring Specification Parameter Accuracy ± 3oC Temperature Reserved Tx Bias Tx Power Rx Power Vcc3 ± 10% ± 2dB ± 2dB ± 3% ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 2/1/2008 V1.0 Optoway 5 XPS-2310W-CXX0G *********************************************************************************************************************************************************************** CONNECTION DIAGRAM Table 3 PIN Description PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Logic LVTTL-I LVTTL-O LVTTL-I LVTTL-I/O LVTTL-I/O LVTTL-O LVTTL-O LVTTL-O CML-O CML-O Signal Name GND VEE5 Mod_Desel Interrupt TX_DIS VCC5 GND VCC3 VCC3 SCL SDA Mod_Abs Mod_NR RX_LOS GND GND RDRD+ GND VCC2 Description Note Module Ground -5.2V Power Supply (Not required) Module De-select; When held low allows module to respond to 2-wire serial interface Interrupt; Indicates presence of an important condition which can be read over the 2wire serial interface Transmitter Disable; Turns off transmitter laser output +5V Power Supply (Not required) Module Ground +3.3V Power Supply +3.3V Power Supply Serial 2-wire interface clock Serial 2-wire interface data line Indicates Module is not present. Grounded in the Module Module Not Ready; Indicating Module Operational Fault Receiver Loss Of Signal Indicator Module Ground Module Ground Receiver Inverted Data Output Receiver Non-Inverted Data Output Module Ground +1.8V Power Supply (Not required) 1 3 2 3 1 2 2 2 2 2 1 1 1 3 ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 2/1/2008 V1.0 Optoway 6 XPS-2310W-CXX0G *********************************************************************************************************************************************************************** 21 LVTTL-I P_Down/RST 22 23 24 PECL-I VCC2 GND RefCLK+ 25 PECL-I RefCLK- 26 27 28 CML-I 29 CML-I 30 GND GND TDTD+ GND Power down; When high, requires the module to limit power consumption to 1.5W or below. 2-Wire serial interface must be functional in the low power mode. Reset; The falling edge initiates a complete reset of the module including the 2-wire serial interface, equivalent to a power cycle. +1.8V Power Supply (Not required) Module Ground Reference Clock Non-Inverted Input, AC coupled on the host board. (Not used. Internally terminated to 50 ohm (100 ohm diff.)) Reference Clock Inverted Input, AC coupled on the host board. (Not used. Internally terminated to 50 ohm (100 ohm diff.)) Module Ground Module Ground Transmitter Inverted Data Input Transmitter Non-Inverted Data Input Module Ground 3 1 4 4 1 1 1 1. Module ground pins GND are isolated from the module case and chassis ground within the module. 2. Shall be pulled up with 4.7K-10Kohms to a voltage between 3.15V and 3.45V on the host board. 3. These PINs are open within module. 4. A Reference Clock input is not required. If present, it will be ignored. Mechanical Specification (Units in mm) ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 2/1/2008 V1.0 Optoway XPS-2310W-CXX0G 7 *********************************************************************************************************************************************************************** Recommended Power Circuit Schematic Host Board VCC5 Optional Host +5V 4.7μH 0.1μF VCC3 Host +3.3V 4.7μH 22μF 0.1μF 0.1μF VCC2 Optional Host +1.8V 4.7μH 22μF 0.1μF XFP Connector 22μF 0.1μF XFP Module 0.1μF VEE5 Optional Host -5.2V 4.7μH 0.1μF 22μF 0.1μF Recommended Interface Circuit XFP module Host Board TD + SerDat Out+ Z=50Ω CML TD - SerDat Out- 100Ω CML Z=50Ω RD + SerDat In+ CML 100Ω Z=50Ω SerDat In- CML RD Z=50Ω Vcc(+3.3V) 4.7K to 10KΩ REFCLKP 100Ω REFCLKN RX_LOS INTERRUPT SDA VCC(+3.3V) SCL MOD_NR 10KΩ MOD_abs TX_DIS GND MOD_DeSel P_Down/RST ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 2/1/2008 V1.0 Optoway XPS-2310W-CXX0G 8 *********************************************************************************************************************************************************************** Table 2 Serial ID Memory Contents (Table 01h) Address Field Size (Byte) 128 1 Identifier 129 130 131~138 139 140 141 142 143 144 145 146 147 1 1 8 1 1 1 1 1 1 1 1 1 Ext. Identifier Connector type Transceiver Encoding BR-Min BR-Max length (SMF)-Km Length (E-50µm) Length (50 µm) Length (62.5 µm) Length (Copper) Device Tech 148~163 164 165~167 16 1 3 Vendor name CDR Support Vendor OUI 168~183 16 Vendor PN 184~185 2 Vendor rev 186~187 2 188~189 190 191 192~195 2 1 1 4 Wavelength Wavelength Tolerance Max Case Temp CC_BASE Power Supply 196~211 16 Vendor SN 212~219 8 220 1 Date code Diagnostic Monitoring Type Name of Filed Description Hex XFP power consumption <2.5W, no Ref Colck required LC connector 10GBASE-LR/LW, 10GFC 1200-SM-LL-L 64B/66B, 8B10B, NRZ 9.9Gbps 10.5Gbps 10 Km 0m 0m 0m 0m Uncooled CWDM DFB, PIN detector 06 +/- 6.5nm 70deg Check sum of Byte 128 -- 190 2Wmax, 1.5W pd_max , 550mA 3.3V 05 14 46 50 07 44 40 00 00 00 00 00 00 D0 63 69 0A 00 00 00 00 50 4F 50 54 4F 57 41 59 20 OPTOWAY 20 20 20 20 20 20 20 20 CDR supports 9.953G ~ 10.52G, XFI Loopback E1 00 0E FA XPS-2310W-CXX0G XX = 27, 29, 31, 33, 35, 37, 39, 41, 43, 45, 47, 58 50 53 2D 32 33 31 30 49, 51, 53, 55, 57, 59, 61 57 2D 43 xx xx 30 47 20 ASCII (“31 61” means 1a revision) xx xx 1XX1nm, XX=27,2 9, 31, 33, 35, 37, 39, 41, 43, 45, 47, 49, 51, 53, 55, 57, 59, 61 xx xx ASCII ASCII Year (2 Byte), Month (2 Byte), Day (2 Byte) No BER Support, Average Power Optional Soft TX_DISABLE implemented, Optional Soft P_down implemented AUX1 for Vcc3. Check sum of Byte 192 -- 222 221 1 Enhanced Options 222 1 Aux Monitoring 223 1 CC_EXT 224~255 32 Vendor Specific Note: Specifications subject to change without notice. 64 96 06 00 xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx 20 20 08 60 70 Reserved ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 2/1/2008 V1.0 Optoway XPS-2310W-CXX0G 9 *********************************************************************************************************************************************************************** Revision History Version 1.0 Subject Release Date Initial datasheet 2008/2/1 ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: [email protected] http: // www.optoway.com.tw 2/1/2008 V1.0