G601 - GMT

G601
Global Mixed-mode Technology
Manual Reset IC with Adjustable Deglitch Time
Features
General Description
„ Manual Reset Input with Adjustable Manual Re
The G601 is a manual reset IC used in µP and digital
systems. They provide excellent circuit reliability and
low cost.
„
„
„
„
„
„
set Deglitch Time
Fully Specified Over Temperature
Open-Drain RESET Output
4µA Supply Current
Guaranteed Reset Valid to VCC = 2.2V
Power Supply Transient Immunity
ADFN1.5X1.5-6 Packages
These circuits perform a single function: they assert a
reset signal whenever manual reset is triggered. Manual reset is generated after pull low MR pin lastingly
over deglitch time delay set by capacitor connected in
MRDLY pin.
The G601 has an open-drain output stage. The
open-drain RESET output requires a pull-up resistor
that can be connected to a voltage higher than VCC.
The reset comparator is designed to ignore fast transients on VCC, and the outputs are guaranteed to be
in the correct logic state for VCC down to 2.2V.
Applications
„ Computers
„ Controllers
„ Intelligent Instruments
„ Critical µP and µC Power Monitoring
„ Portable / Battery-Powered Equipment
Low supply current makes the G601 ideal for use in
portable equipment. The G601 is available in
ADFN1.5X1.5-6 packages.
Ordering Information
ORDER NUMBER
MARKING
TEMP. RANGE
PACKAGE
(Green)
G601A31U
60
1x
-40°C ~ +105°C
ADFN1.5X1.5-6
Note: A3:ADFN1.5X1.5-6
1: Bonding Code
U: Tape & Reel
Pin Configuration
Typical Application Circuit
VCC
G601
VCC
VCC
MRDLY
MRDLY
1
6
VCC
GND
2
5
RESET
CMR
Rpull-up*
µP
G601
RESET
MR1
3
4
MR
MR1
MR
GND
RESET
INPUT
GND
ADFN1.5X1.5-6
TEL: 886-3-5788833
http://www.gmt.com.tw
Ver:0.3
Jun 01, 2012
1