Single Programmable Attenuator Systems
Model Number
Impedance
Attenuation
Frequency Range
Control
Page
50PA-179
50 Ohm
0-85 x 1
DC-3000 MHz
GPIB
1-8
50PA-263
50 Ohm
0-127 x 1
DC-1000 MHz
GPIB
1-8
50PA-270
50 Ohm
0-127 x 1
800-2400 MHz
GPIB
1-8
50PA-285
50 Ohm
0-127 x 1
DC-1000 MHz
GPIB
1-7
50PA-297
50 Ohm
0-63 x 1
200-6000 MHz
Ethernet/RS-232
1-4
50PA-308
50 Ohm
0-127 x 1
500-2500 MHz
Ethernet/RS-232
1-4
75PA-024
75 Ohm
0-95.5 x 0.5
50-860 MHz
GPIB
1-8
75PA-031
75 Ohm
0-63 x 1
5-1000 MHz
Ethernet/RS-232
1-4
Model Number
Impedance
Quantity / Attenuation
Frequency Range
Control
Page
50PA-300
50 Ohm
Eight of 0-127 x 1
500-2500 MHz
Ethernet/RS-232
1-5
50PA-330
50 Ohm
Four of 0-63 x 1
200-6000 MHz
Ethernet/RS-232
1-6
50PA-350
50 Ohm
Four of 0-127 x 1
800-2400 MHz
Ethernet/RS-232
1-3
50PA-409
50 Ohm
Four of 0-63 x 1
200-6000 MHz
Ethernet/RS-232
1-3
Multiple Programmable Attenuator Systems
Custom Capabilities with no NREs
This section of the catalog showcases some standard attenuator assemblies. However, most of JFW’s test system
business involves custom designed models. JFW does not charge NRE’s for custom models. We encourage you to
email us your requirement ([email protected]). We will respond with a ROM (rough order of magnitude) quote
in 1-2 days. Please include a block diagram with your request if the test system involves multiple RF components.
Available Options
- GPIB, RS-232, TTL, or Ethernet control
- Electro-mechanical programmable attenuators
- Frequency ranges from DC-18 GHz
- Solid-state programmable attenuators
- Keypad for manual control
- Attenuation resolution from 0.1dB to 10dB
- 19”, 23”, 24” rack enclosures
- Various RF connector options (BNC, TNC, SMA, N, etc.)
- Benchtop enclosures
- 50 Ohm and 75 Ohm impedance
- Dual redundant power supplies
- GUI Test Software Provided
1-2
Benchtop Programmable Attenuator Assemblies
Attenuation Accuracy
Model
Configuration
Frequency Range
50PA-350
Four solid-state programmable attenuators
800-2400 MHz
0-127 dB x 1 dB
1, 2, 4, 8, 16, 32 and 64 dB
+/- 0.4 or 2%
50PA-409
Four solid-state programmable attenuators
200-6000 MHz
0-63 dB x 1 dB
1, 2, 4, 8, 16, and 32 dB
+/- 1.0 dB or 4%
Model
Insertion Loss
(maximum)
RF Input Power Impedance
50PA-350
5.0 dB
+20 dBm
50PA-409
7.0 dB
+20 dBm
Attenuation Range/
Steps
Switching Speed
(typical)
Operating
Temperature
VSWR
(maximum)
50 Ohms
5 microseconds (after command is processed)
(3 milliseconds typical processing time)
0ºC to +50ºC
1.5:1
50 Ohms
1 microsecond (after command is processed)
(3 milliseconds typical processing time)
0ºC to +50ºC
2.3:1
Model
AC Supply
Control
RF Connector
50PA-350
100-240 VAC @ 47-63 Hz
Ethernet(10/100)/RS-232/Manual
BNC, TNC, N or SMA female
50PA-409
100-240 VAC @ 47-63 Hz
Ethernet(10/100)/RS-232/Manual
SMA or N female
Remote Commands
Set Attenuator, Read Attenuator, Fade Attenuator, Variable Handover, Change Baud Rate, Identification
1-3
Single Programmable Attenuator Assemblies
Attenuation Accuracy
Insertion Loss
RF Input Power
(average)
0-63 dB x 1 dB
1, 2, 4, 8, 16 and 32 dB
+/- 1.0 dB or 4%
7.0 dB nominal
+20 dBm
500-2500 MHz
0-127 dB x 1 dB
1, 2, 4, 8, 16, 32 and 64 dB
+/- 0.5 dB or 2%
5.5 dB maximum
2.0 dB typical @ 500 MHz
4.0 dB typical @ 2500 MHz
+20 dBm
5-1000 MHz
0-63 dB x 1 dB
1, 2, 4, 8, 16 and 32 dB
+/- 0.5 dB or 2%
2.5 dB typical @ 5 MHz
4.3 dB typical @ 1000 MHz
+13 dBm
Model
Frequency Range
50PA-297
200-6000 MHz
50PA-308
75PA-031
Attenuation Range/
Steps
Model
Impedance
(nominal)
Switching Speed
(typical)
VSWR
(maximum)
RF Connectors
50PA-297
50 Ohms
1 microsecond (after command is processed)
(3 milliseconds typical processing time)
2.3:1
SMA female
50PA-308
50 Ohms
5 microseconds (after command is processed)
(3 milliseconds typical processing time)
1.6:1
SMA, BNC, TNC or N female
75PA-031
75 Ohms
25 microseconds (after command is processed)
(3 milliseconds typical processing time)
1.6:1
F, BNC or N Female
Common Specifications
Configuration
Control
AC Supply
Operating Temperature
Single Solid-state programmable attenuator
Ethernet(10/100)/RS-232/Manual
100-240 VAC @ 47-63 Hz
0ºC to +50ºC
Remote Commands
Set Attenuator, Read Attenuator, Fade Attenuator, Change Baud Rate, Identification
1-4
Programmable Attenuator Assembly
Model
Configuration
Frequency Range
VSWR
(maximum)
Attenuation Accuracy
50PA-300
Eight solid-state programmable attenuators
500-2500 MHz
1.6:1
± 0.5 dB or 2%
Insertion Loss
Attenuation Range/Steps
Switching Speed
(typical)
6 dB maximum
2 dB typical @ 500 MHz
5 dB typical @ 2500 MHz
0-127 dB x 1 dB
1, 2, 4, 8, 16, 32 and 64 dB
5 microseconds (after command is processed)
(3 milliseconds typical processing time)
AC Supply
Input Power
(average)
Impedance
Operating
Temperature
Control
RF Connectors
100-240 VAC @ 47-63 Hz
+20 dBm
50 Ohms
0ºC to +50ºC
Ethernet(10/100)/RS-232/Manual
SMA female
Remote Commands
Set Attenuator, Read Attenuator, Fade Attenuator, Variable Handover, Change Baud Rate, Identification
1-5
Programmable Attenuator Assembly
Model
Configuration
Frequency Range
VSWR
(maximum)
Attenuation Accuracy
50PA-330
Four Solid-state programmable attenuators
200-6000 MHz
2.3:1
+/- 1.0 dB or 4%
Insertion Loss
Attenuation Range/Steps
Switching Speed
(typical)
AC Supply
7.0 dB typical
0-63 dB x 1 dB
1, 2, 4, 8, 16 and 32 dB
1 microsecond (after command is processed)
(3 milliseconds typical processing time)
100-240 VAC @ 47-63 Hz
Input Power
(average)
Impedance
Operating
Temperature
Control
RF Connectors
+20 dBm
50 Ohms
0ºC to +50ºC
Ethernet(10/100)/RS-232/Manual
SMA female
Remote Commands
Set Attenuator, Read Attenuator, Fade Attenuator, Variable Handover, Change Baud Rate, Identification
1-6
Benchtop Programmable Attenuator Assembly
Model
50PA-285
Frequency Range Attenuation Range/
Steps
DC-1000 MHz
0-127 dB x 1 dB
1, 2, 4, 8, 16, 32 and 64 dB
Impedance Switching Speed
50 Ohms
6 milliseconds (after command is processed)
(5 milliseconds typical processing time)
Attenuation Accuracy
Individual Attenuation Pads
1, 2, 4, 8 dB +/- 0.2 dB
16, 32, 64 dB +/- 0.4 dB
Combination Values
0-31 dB +/- 0.5 dB
32-127 dB +/- 1.0 dB
Insertion Loss RF Input Power Control
(nominal)
(average)
3.5 dB
1 Watt
GPIB/Manual
Operating
Temperature
VSWR
(maximum)
AC Supply
RF Connectors
0ºC to +50ºC
1.5:1
100-240 VAC @ 47-63 Hz
BNC, TNC, N or
SMA female
Remote Commands
Set Attenuator, Read Attenuator, Identification, Event Status Register, Reset
1-7
Single Programmable Attenuator Assemblies
Model
Frequency Range Attenuation Range/
Steps
50PA-179
DC-3000 MHz
Attenuation Accuracy
0-85 dB x 1 dB
1, 2, 4, 8, 10, 20 and 40 dB
+/+/+/+/-
Individual Attenuation Values
1, 2, 4, 8 dB +/- 0.2 dB
16, 32, 64 dB +/- 0.4 dB
Combination Values
0-31 dB +/- 0.5 dB
32-127 dB +/- 1 dB
50PA-263
DC-1000 MHz
0-127 dB x 1 dB
1, 2, 4, 8, 16, 32 and 64 dB
50PA-270
800-2400 MHz
0-127 dB x 1 dB
1, 2, 4, 8, 16, 32 and 64 dB
75PA-024
50-860 MHz
0-95.5 dB x 0.5 dB
0.5, 1, 2, 4, 8, 16, 32 and 32 dB
Model
Impedance RF Input Power Switching Speed
(average)
(typical)
50PA-179
50 Ohms
1 Watt
50PA-263
50 Ohms
1 Watt
50PA-270
50 Ohms
+20 dBm
75PA-024
75 Ohms
+15 dBm
0.3
0.4
0.5
0.6
dB
dB
dB
dB
or
or
or
or
0.5%
1.0%
1.0%
1.5%
DC-500 MHz
500-1000 MHz
1000-2000 MHz
2000-3000 MHz
+/- 0.3 dB or 2%
0.5, 1 and 2 dB
+/- 0.2 dB
4 and 8 dB
+/- 0.3 dB
16, 32 and 32 dB +/- 0.4 dB
Accumulated Error +/- 0.5 dB or 1%
VSWR
(maximum)
Insertion Loss
(nominal)
1.6:1
2.75 dB DC-1000 MHz
3.75 dB 1000-2000 MHz
4.75 dB 2000-3000 MHz
1.5:1
3.5 dB
1.5:1
2.3 dB @ 800 MHz
4.5 dB @ 2400 MHz
1.5:1
4 dB
AC Supply
6 milliseconds (after command is processed)
(5 milliseconds typical processing time)
6 milliseconds (after command is processed)
(5 milliseconds typical processing time)
20 microseconds (after command is processed)
(5 milliseconds typical processing time)
20 microseconds (after command is processed)
(5 milliseconds typical processing time)
RF Connectors
100-240 VAC @ 47-63 Hz
100-240 VAC @ 47-63 Hz
100-240 VAC @ 47-63 Hz
100-240 VAC @ 47-63 Hz
BNC, TNC, N or
SMA female
BNC, TNC, N or
SMA female
BNC, TNC, N or
SMA female
F, BNC or N female
Common Specifications
Configuration
Control
AC Supply
Operating Temperature
Single Programmable Attenuator
GPIB/Manual
100-240 VAC @ 47-63 Hz
0°C to +50°C
Remote Commands
Set Attenuator, Read Attenuator, Identification, Event Status Register, Reset
See next page for outline drawing.
1-8
Programmable Attenuator Assemblies
Outline Drawing of model 50PA-179, 50PA-263, 50PA-270, 75PA-024
1-9