Additional JFW Brochures Test Systems Brochure Contains information on JFW's standard and custom RF test boxes, including: Matrix Switches Handover Test Systems Programmable Attenuator Assemblies Transceiver Test Systems Switch Assemblies Custom RF Assemblies 75 Ohm Components Brochure See what JFW has to offer for cable TV and other 75 Ohm applications, including: Programmable Attenuators Rotary Attenuators Fixed Attenuators Terminations RF Switches Power Dividers Impedance Matching Pads DC Blocks RF Detectors Bias Taps www.jfwindustries.com JFW's Quality Policy “JFW is committed to anticipating and exceeding customer’s requirements and expectations through cost-competitive, quality products and services that are delivered on time and through continual improvements to our quality management system.” JFW's Standard Terms and Conditions JFW Industries, Inc. has standard terms of Net 30 days with approved credit. Alternate methods of payment include MASTERCARD, American Express, VISA, COD or ADVANCE PAYMENT. International Payment Terms are ADVANCE PAYMENT or MASTERCARD, American Express and VISA. Any other payment terms must be negotiated in advance. Shipping terms are FOB JFW Ind for Domestic Customers and FCA JFW Ind for International Customers. ALL SHIPPING CHARGES will be PREPAID and ADDED TO THE INVOICE or SHIPPED COLLECT VIA YOUR DESIGNATED FREIGHT CARRIER. JFW INDUSTRIES WARRANTY JFW PRODUCTS ARE WARRANTED AGAINST DEFECTS IN WORKMANSHIP AND MATERIAL UNDER NORMAL USE AND SERVICE AS FOLLOWS: (2) TWO YEARS FROM DATE OF SHIPMENT FOR ALL FIXED AND SOLID STATE PRODUCTS. (1) ONE YEAR FROM DATE OF SHIPMENT FOR ALL MECHANICAL AND ELECTRO-MECHANICAL PRODUCTS. JFW INDUSTRIES’ ONLY OBLIGATION UNDER THIS WARRANTY IS TO REPAIR OR REPLACE, AT ITS FACTORY, ANY JFW PRODUCT OR PART THEREOF THAT IS RETURNED TO JFW INDUSTRIES BY THE ORIGINAL PURCHASER WITHIN THE WARRANTY PERIOD. THE WARRANTY STATED ABOVE IS YOUR SOLE AND EXCLUSIVE WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR FITNESS FOR ANY PARTICULAR PURPOSE. JFW INDUSTRIES SHALL NOT BE LIABLE FOR ANY DIRECT OR CONSEQUENTIAL INJURY, LOSS OR DAMAGE INCURRED THROUGH THE USE, OR INABILITY TO USE, ANY JFW INDUSTRIES PRODUCT. JFW Industries, Inc. 5134 Commerce Square Drive Indianapolis, Indiana 46237 Call-317-887-1340 Toll Free-877-887-4JFW (4539) Fax-317-881-6790 E-mail: [email protected] JFW International Sales 7 Albion Road South Benfleet Essex, UK SS7 5PU Phone +44 7768-662666 Fax +44 1268-795377 E-mail: [email protected] Catalog 17 Printed 03-2015 Solid-State Programmable Attenuators • • • • • +20 dBm power handling typical Long lifetime solid-state design Frequencies up to 6 GHz 0.1, 0.25, 0.5, 1, 10 dB step sizes available Various Connectors available (SMA, N, BNC, TNC) Featured Models* See website for complete specifications and drawings. Model Range Frequency Max IL 50P-1867 0-31.75 x 0.25 dB 30-3000 MHz 2.5 dB 50P-1891 0-63.5 x 0.5 dB 30-3000 MHz 4.0 dB 50P-1893 0-63 x 1 dB 30-3000 MHz 4.0 dB 50P-1897 0-95 x 1 dB 30-3000 MHz 6.0 dB 50P-1782 0-127 x 1 dB 15-2000 MHz 6.0 dB 50P-1501 0-127 x 1 dB 200-3000 MHz 6.0 dB 50P-1900 0-127 x 1 dB 700-3000 MHz 6.0 dB Wide Band Series • • • 200-6000 MHz +20 dBm power handling Digitally latching models also available Wide Band Series Model Range Max IL 50P-1855 0-31.5 x 0.5 dB 3.5 dB 50P-1853 0-63 x 1 dB 5.5 dB 50P-1857 0-95 x 1 dB 8.0 dB *Visit our website for an expanded list of models. www.jfwindustries.com/programmables JFW Industries 317-887-1340 [email protected] 4 Relay Programmable Attenuators • • • • • 1 Watt power handling typical Low distortion Frequencies up to 6 GHz 0.1, 0.25, 0.5, 1, 10 dB step sizes available Various Connectors available (SMA, N, BNC, TNC) Featured Models* See website for complete specifications and drawings. Model Range Frequency Max IL 50P-542 0-10 x 1 dB DC-2800 MHz 3.0 dB 50P-847 0-15 x 1 dB DC-5000 MHz 4.0 dB 50P-1978 0-63 x 1 dB DC-2700 MHz 4.0 dB 50P-1633 0-64.5 x 0.1 dB DC-1000 MHz 4.0 dB 50P-1516 0-70 x 10 dB DC-6000 MHz 3.5 dB 50P-591 0-85 x 1 dB DC-3000 MHz 4.5 dB 50P-1976 0-127 x 1 dB DC-1000 MHz 2.0 dB 50P-1436 0-127 x 1 dB DC-2500 MHz 4.3 dB High Power Models • • • Designs with power handling up to 10 Watts available Frequencies up to 3 GHz Various step sizes available Featured Models* See website for complete specifications and drawings. Model Range Frequency Power Max IL 50P-1941 0-15 x 1 dB DC-3000 MHz 10 W 5.0 dB 50P-1930 0-63 x 1 dB DC-200 MHz 10 W 0.2 dB 50P-1849 0-63 x 1 dB DC-2700 MHz 10 W 4.0 dB *Visit our website for an expanded list of models. www.jfwindustries.com/programmables 5 JFW Industries 317-887-1340 [email protected] Manually Variable Attenuators Rotors (single shaft) • • • 2W power handling See website for 6 GHz, 8 GHz and 18 GHz models Available in 0.1 dB, 1 dB and 10 dB steps Featured Models* See website for complete specifications and drawings. Model Range Frequency Max IL 50R-028 0-1 x 0.1 dB DC-1000 MHz 1.0 dB 50R-215 0-1 x 0.1 dB DC-2200 MHz 1.0 dB 50R-249 0-1 x 0.1 dB DC-2500 MHz 1.0 dB 50R-019 0-10 x 1 dB DC-2200 MHz 0.4 dB 50R-248 0-10 x 1 dB DC-2500 MHz 0.5 dB 50R-310 0-10 x 1 dB DC-2700 MHz 0.5 dB 50R-385 0-10 x 1 dB DC-3000 MHz 0.6 dB 50R-029 0-70 x 10 dB DC-2200 MHz 0.5 dB 50R-124 0-70 x 10 dB DC-2500 MHz 0.5 dB 50R-246 0-70 x 10 dB DC-2700 MHz 0.6 dB 50R-043 0-100 x 10 dB DC-1000 MHz 0.3 dB 50R-234 0-100 x 10 dB DC-2550 MHz 1.0 dB Rotors (benchtop) • • • • Enclosed or L-bracket models available 2W power handling See website for 6 GHz, 8 GHz and 18 GHz models Available in 0.1 dB, 1 dB and 10 dB steps Featured Models* See website for complete specifications and drawings. Model Range Frequency Max IL 50BR-092 0-81 X 0.1 dB DC-1000 MHz 1.5 dB 50BR-068 0-110 x 1 dB DC-2550 MHz 1.8 dB 50BR-112 0-110 x 1 dB DC-2700 MHz 2.2 dB Don't see what you're looking for? *Visit our website for additional models including Pushbutton, Toggle and Rocker Switch Attenuators. www.jfwindustries.com/rotors JFW Industries 317-887-1340 [email protected] 6 Manually Variable Attenuators Rotors (dual shaft) • • • 2W power handling See website for 6 GHz, 8 GHz and 18 GHz models Available in 0.1 dB or 1 dB steps Featured Models* See website for complete specifications and drawings. Model Range Frequency Max IL 50DR-060 0-11 X 0.1 dB DC-2000 MHz 1.25 dB 50DR-055 0-30 X 1 dB DC-2000 MHz 0.8 dB 50DR-096 0-30 X 1 dB DC-3000 MHz 1.1 dB 50DR-063 0-50 X 1 dB DC-1100 MHz 0.5 dB 50DR-046 0-50 X 1 dB DC-2500 MHz 1.1 dB 50DR-111 0-60 X 1 dB DC-2700 MHz 1.2 dB 50DR-061 0-80 X 1 dB DC-2200 MHz 1.0 dB 50DR-125 0-80 X 1 dB DC-2700 MHz 1.5 dB 50DR-001 0-110 x 1 dB DC-1000 MHz 0.5 dB 50DR-082 0-110 x 1 dB DC-2000 MHz 1.0 dB 50DR-119 0-110 x 1 dB DC-2200 MHz 1.0 dB Rotors (panel mounted) • • • 19 inch rack mount panel typical Panel mounting available for any JFW rotor Custom designs in-line w/ catalog pricing Featured Models* See website for complete specifications and drawings. Model Range Frequency Panel Height 50PM-109 (8) 0-110 x 1 dB DC-2000 MHz 2RU 50PM-060 (2) 0-50 x 1 dB DC-2500 MHz 1RU 50PM-075 (4) 0-50 x 1 dB DC-2500 MHz 1RU 50PM-003 (8) 0-50 x 1 dB DC-2500 MHz 2RU 50PM-059 (2) 0-60 x 1 dB DC-2700 MHz 1RU 50PM-074 (4) 0-60 x 1 dB DC-2700 MHz 1RU 50PM-057 (8) 0-60 x 1 dB DC-2700 MHz 2RU 7 JFW Industries 317-887-1340 [email protected] Fixed Attenuators Low Power • See website for complete listing of low power fixed attenuators. Featured Models* See website for complete specifications and drawings. Series Frequency Power Connector 50F DC-2200 MHz 1W BNC or TNC 50HB DC-6 GHz 2W SMA 50HN DC-6 GHz 2W N 50HF DC-18 GHz 2W SMA or N Medium Power • See website for complete listing of 5-50 Watt fixed attenuators. Featured Models* See website for complete specifications and drawings. Series Frequency Power Heatsink 50FPE DC-6 GHz 5W None 50HF DC-18 GHz 5W, 10W Round* 50HF DC-18 GHz 25W, 50W Square 50FHC DC-4 GHz 10W, 15W, 20W, 25W Round* 50FHXC DC-4 GHz 40W, 50W Round* 50FH DC-3 GHz 30W, 50W Square * These models with round heatsinks lack mounting holes. High Power • See website for complete listing of 75-1000 Watt fixed attenuators. Featured Models* See website for complete specifications and drawings. Series Frequency Power Heatsink 50FHAO DC-3 GHz 75W Square 50FH DC-3 GHz 80W, 100W Square 50FHAO DC-3 GHz 100W, 150W, 200W Round 50HF DC-6 GHz 100W Square 50FH DC-2 GHz 300W Square 50FHDQ DC-3 GHz 500W Square 50FHIE DC-3 GHz 1000W Square *Visit our website for an expanded list of models. www.jfwindustries.com/fixed JFW Industries 317-887-1340 [email protected] 8 Terminations Low Power • See website for complete listing of low power terminations/mismatches. Featured Models* See website for complete specifications and drawings. Model Frequency Power Connector 50T-001 DC-2200 MHz 1W BNC male 50T-007 DC-8 GHz 2W N male 50T-455 DC-18 GHz 1W SMA male 50T-199 DC-18 GHz 2W N male Medium Power • See website for complete listing of 5-50 Watt terminations/mismatches. Featured Models* Model See website for complete specifications and drawings. Frequency Power Connector Heatsink* 50T-410 DC-4 GHz 5W BNC, N, SMA, TNC or RPT None 50T-128 DC-18 GHz 5W SMA Round* 50T-191 DC-18 GHz 5W N Round* 50T-439 DC-3 GHz 10W BNC, N, SMA, TNC, 7/16 Round* 50T-440 DC-3 GHz 25W BNC, N, SMA, TNC, 7/16 Round* 50T-506 DC-3 GHz 50W BNC, N, SMA, TNC, 7/16 Round* 50T-533 DC-6 GHz 50W N, SMA, 7/16 Square 50T-489 DC-18 GHz 50W N, SMA Square * These models with round heatsinks lack mounting holes. High Power • See website for complete listing of 75-1000 Watt terminations/mismatches. Featured Models* See website for complete specifications and drawings. Model Frequency Power Connector Heatsink 50T-549 DC-3 GHz 75W BNC, N, SMA, TNC, 7/16 Square 50T-243 DC-3 GHz 100W BNC, N, SMA, TNC, 7/16 Square 50T-390 DC-6 GHz 100W N, 7/16 Round 50T-338 DC-3 GHz 200W N, 7/16 Round 50T-421 DC-3 GHz 500W N, TNC, 7/16 Square 50T-495 DC-3 GHz 1000W N, 7/16 Square Many terminations also available in mismatch version. *See website for more details. www.jfwindustries.com/term 9 JFW Industries 317-887-1340 [email protected] Solid-State RF Switches • • • • • • 1P1T to 1P16T standard configurations Long lifetime solid-state design 1 Watt power handling typical See website for 18 GHz models Typical switching speed in the microseconds Reflective or absorptive models available Featured Models* See website for complete specifications and drawings. Model Type Frequency Max IL Min Isolation 50S-1560 1P1T 5-3000 MHz 3.5 dB 50 dB 50S-1970 1P2T 5-3000 MHz 3.5 dB 60 dB 50S-1971 1P4T 5-3000 MHz 3.5 dB 60 dB 50S-1972 1P8T 5-3000 MHz 3.5 dB 60 dB 50S-1220 1P2T 20-4300 MHz 3.0 dB 55 dB 50S-1075 1P4T 20-4300 MHz 4.0 dB 55 dB 50S-1310 1P8T 20-4300 MHz 4.5 dB 50 dB 50S-1567 1P12T 20-4300 MHz 4.5 dB 50 dB 50S-1584 1P16T 20-4300 MHz 5.5 dB 50 dB 50S-1876 1P2T 20-6000 MHz 2.5 dB 55 dB High Power Models • • • • 1P2T to 1P6T standard configurations Frequencies up to 3 GHz Up to 250W cold-switching, 100W hot-switching and 2kW peak power handling Typical switching speeds < 40 microseconds Featured Models* See website for complete specifications and drawings. Model Type Frequency Max IL Min Isolation Input Power 50S-1872 1P2T 20-500 MHz 0.6 dB 50 dB 5W cold switch, 5W hot switch 50S-1559 1P2T 20-1000 MHz 0.75 dB 40 dB 150W cold switch, 50W hot switch 50S-1422 1P2T 100-500 MHz 0.5 dB 55 dB 250W cold switch, 100W hot switch 50S-1841 1P2T 500-3000 MHz 1.25 dB 55 dB 30W cold switch, 30W hot switch 50S-1820 1P2T 800-2700 MHz 1.2 dB 60 dB 100W cold switch, 30W hot switch 50S-1832 1P2T 960-1300 MHz 0.75 dB 40 dB 200W cold switch, 1kW peak w/ 35 usec pulse *Visit our website for an expanded list of models. www.jfwindustries.com/switch JFW Industries 317-887-1340 [email protected] 10 Electro-Mechanical RF Switches Reflective Switches (Unused ports open) • • • • All models operate from DC-18 GHz Voltage options include +12V, +15V, +24V, +28V TTL controlled models available upon request. 20 milliseconds typical switching speed Featured Models* See website for complete specifications and drawings. Reflective Models Type Max IL Min Isolation 50S-1313 1P2T failsafe 0.35 dB 60 dB 50S-1360 1P3T normally open 0.5 dB 60 dB 50S-1315 1P4T normally open 0.5 dB 60 dB 50S-1316 1P6T normally open 0.5 dB 60 dB 50S-1317 1P8T normally open 0.8 dB 55 dB 50S-1443 1P12T normally open 0.8 dB 60 dB 50S-1361 Transfer switch 0.5 dB 60 dB Absorptive Switches (Unused ports self-terminating into 50 Ohms) • • • • All models operate from DC-18 GHz Voltage options include +12V, +15V, +24V, +28V TTL controlled models available upon request. 20 milliseconds typical switching speed Featured Models* See website for complete specifications and drawings. Absorptive Models Type Max IL Min Isolation 50S-1603 1P2T failsafe 0.5 dB 60 dB 50S-1657 1P3T normally open 0.5 dB 60 dB 50S-1650 1P4T normally open 0.5 dB 60 dB 50S-1638 1P6T normally open 0.5 dB 60 dB 50S-1614 1P8T normally open 0.5 dB 60 dB Power Table Frequency Range Max Average RF Power DC-100 MHz 100-200 MHz 200-500 MHz 500-1000 MHz 500 Watts 400 Watts 300 Watts 200 Watts 1-4 GHz 4-8 GHz 100 Watts 90 Watts 8-12 GHz 12-18 GHz 70 Watts 60 Watts *Visit our website for more models. www.jfwindustries.com/switch 11 JFW Industries 317-887-1340 [email protected] Resistive Power Dividers / Combiners Resistive - Low Power • • Models listed below available with SMA only. See website for additional types and connector options (N, BNC, TNC). Featured Models* See website for complete specifications and drawings. Model Type Frequency Power IL 50PD-016 2-Way DC-4000 MHz 2W 6 dB 50PD-292 3-Way DC-4000 MHz 2W 9.5 dB 50PD-293 4-Way DC-4000 MHz 2W 12 dB 50PD-785 16-Way DC-2000 MHz 1W 24 dB DC-6 GHz Series High Power Models SMA female connectors 1W RF Input Power Type Model 2-Way Up to 200W RF Input Power Model Type Frequency Power 50PD-478 50PD-377 2-Way DC-500 MHz 200W 3-Way 50PD-469 50PD-670 2-Way DC-3000 MHz 30W 4-Way 50PD-771 50PD-667 3-Way DC-3000 MHz 30W 5-Way 50PD-732 50PD-631 4-Way DC-2000 MHz 30W 7-Way 50PD-734 8-Way 50PD-746 9-Way 50PD-760 11-Way 50PD-735 Visit our website for an expanded list of models. www.jfwindustries.com/divider JFW Industries 317-887-1340 [email protected] 12 Reactive Power Dividers / Combiners Reactive - Low Power • • • Several series available that cover common frequency bands 5 Watts average power handling when used as a divider 20 dB isolation typical Featured Models* See website for complete specifications and drawings. Frequency Connector 2-Way 4-Way 8-Way 800-2400 MHz SMA 50PD-559 50PD-560 50PD-570 20-3000 MHz SMA 50PD-590 50PD-591 50PD-687 698-3000 MHz SMA 50PD-659 50PD-660 50PD-665 698-3000 MHz N 50PD-727 50PD-728 50PD-742 2000-6000 MHz SMA 50PD-634 50PD-638 50PD-647 500-6000 MHz SMA 50PD-645 50PD-650 50PD-662 19" Rack Assemblies High Power Models Contact JFW for your custom solution. Custom designed in-line w/ catalog pricing. Up to 250W RF Input Power Various Connectors available (SMA, N, TNC) Model Description Model Type Frequency Power 50PDA-040 24-Way divider in a 3U 19" rack 50PD-700 2-Way 380-400 MHz 200W 50PDA-071 8-Way divider in a 1U 19" rack 50PD-424 2-Way 800-900 MHz 200W 50PDA-096 4-Way divider in a 1U 19" rack 50PD-698 2-Way 700-3000 MHz 100W 50PD-759 4-Way 350-500 MHz 250W Visit our website for an expanded list of models. www.jfwindustries.com/divider 13 JFW Industries 317-887-1340 [email protected] Test Accessories Impedance Matching 57Z series 57ZT series 57ZTT series Typical Specifications Resistive Matching Pad Toroidal Matching Transformer Microstrip Matching Transformer Frequency coverage from DC up to 3 GHz Low Frequency 0.5-1000 MHz Frequencies starting @ 300 MHz Up to 3 GHz 5.7 dB Insertion Loss <1 dB Insertion Loss <1 dB Insertion Loss 1W average 1W average 20W average Resistive Coupler Resistive couplers differ from standard directional couplers in several important ways: • Minimum coupling value of 20dB • Couples signal in both directions • No directivity Model Frequency Range Power 50C-041 DC-2 GHz 5W 50C-045 DC-6 GHz 1W 50C-051 DC-3 GHz 2W Visit our website for an expanded list of models. www.jfwindustries.com/testaccessories JFW Industries 317-887-1340 [email protected] 14 Test Accessories RF Detectors • • Converts an RF signal into a DC voltage level The DC voltage level corresponds to the RF signal amplitude Featured Models* See website for complete specifications and drawings. Model Frequency Max RF Input Power 50D-050 1-1000 MHz 100 mW 50D-051 1-2000 MHz 100 mW 50D-052 1-3000 MHz 100 mW DC Blocks • Blocks DC voltage while passing RF signal Featured Models* See website for complete specifications and drawings. Model Frequency Max DC Voltage 50DB-007 10 MHz-18 GHz 200V 50DB-009 10-4000 MHz 50V 50DB-039 200 KHz-2000 MHz 100V Bias Taps • Used to add or remove DC voltage from a coaxial cable Featured Models* See website for complete specifications and drawings. Model Frequency DC Voltage DC Current 50BT-014 800-2500 MHz 150V 5A 50BT-017 100-1750 MHz 200V 2A 50BT-029 250-3000 MHz 100V 1A 50BT-067 10-2200 MHz 100V 4A Visit our website for an expanded list of models. www.jfwindustries.com/testaccessories 15 JFW Industries 317-887-1340 [email protected] Engineering Reference Guide Effect of VSWR on Transmitted Power VSWR 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.15 1.20 1.25 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 8.50 9.00 9.50 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 20.00 25.00 30.00 JFW Industries Return Loss (dB) 46.1 40.1 36.6 34.2 32.3 30.7 29.4 28.3 27.3 26.4 23.1 20.8 19.1 17.7 15.6 14.0 12.7 11.7 10.9 10.2 9.5 7.4 6.0 5.1 4.4 3.9 3.5 3.2 2.9 2.7 2.5 2.3 2.2 2.1 1.9 1.8 1.7 1.6 1.5 1.3 1.2 1.2 1.1 1.0 1.0 .9 .9 .7 .6 Trans. Loss (dB) .000 .000 .001 .002 .003 .004 .005 .006 .008 .010 .021 .036 .054 .075 .122 .177 .238 .302 .370 .440 .512 .881 1.249 1.603 1.938 2.255 2.553 2.834 3.100 3.351 3.590 3.817 4.033 4.240 4.437 4.626 4.807 5.149 5.466 5.762 6.042 6.301 6.547 6.780 7.002 7.212 7.413 8.299 9.035 317-887-1340 Volt Refl. Coeff. .01 .01 .02 .02 .02 .03 .03 .04 .04 .05 .07 .09 .11 .13 .17 .20 .23 .26 .29 .31 .33 .43 .50 .56 .60 .64 .67 .69 .71 .73 .75 .76 .78 .79 .80 .81 .82 .83 .85 .86 .87 .88 .88 .89 .89 .90 .90 .92 .94 Power Trans. (%) 99.9 99.9 99.9 99.9 99.9 99.9 99.9 99.9 99.8 99.8 99.5 99.2 98.8 98.3 97.2 96.0 94.7 93.3 91.8 90.4 88.9 81.6 75.0 69.1 64.0 59.5 55.6 52.1 49.0 46.2 43.7 41.5 39.5 37.7 36.0 34.5 33.1 30.6 28.4 26.5 24.9 23.4 22.1 21.0 19.9 19.0 18.1 14.8 12.5 [email protected] Power Refl. (%) .0 .0 .0 .0 .1 .1 .1 .1 .2 .2 .5 .8 1.2 1.7 2.8 4.0 5.3 6.7 8.2 9.6 11.1 18.4 25.0 30.9 36.0 40.5 44.4 47.9 51.0 53.8 56.2 58.5 60.5 62.3 64.0 65.5 66.9 69.4 71.6 73.5 75.1 76.6 77.9 79.0 80.1 81.0 81.9 85.2 87.5 16 Power Conversion Table dBm -20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20.0 20.5 21.0 21.5 22.0 22.5 23.0 23.5 24.0 24.5 Milliwatts 0.01 0.01 0.02 0.02 0.03 0.03 0.04 0.05 0.06 0.08 0.10 0.13 0.16 0.20 0.25 0.32 0.40 0.50 0.63 0.79 1.00 1.26 1.58 2.00 2.51 3.16 3.98 5.01 6.31 7.94 10.00 12.59 15.85 19.95 25.12 31.62 39.81 50.12 63.10 79.43 100.0 112.2 125.9 141.3 158.5 177.8 199.5 223.9 251.2 281.8 dBm 25.0 25.5 26.0 26.5 27.0 27.5 28.0 28.5 29.0 29.5 30.0 30.5 31.0 31.5 32.0 32.5 33.0 33.5 34.0 34.5 35.0 35.5 36.0 36.5 37.0 37.5 38.0 38.5 39.0 39.5 40.0 40.5 41.0 41.5 42.0 42.5 43.0 43.5 44.0 44.5 45.0 45.5 46.0 46.5 47.0 47.5 48.0 48.5 49.0 49.5 50.0 Watts 0.32 0.35 0.40 0.45 0.50 0.56 0.63 0.71 0.79 0.89 1.00 1.12 1.26 1.41 1.58 1.78 2.00 2.24 2.51 2.82 3.16 3.55 3.98 4.47 5.01 5.62 6.31 7.08 7.94 8.91 10.00 11.22 12.59 14.13 15.85 17.78 19.95 22.39 25.12 28.18 31.62 35.48 39.81 44.67 50.12 56.23 63.10 70.79 79.43 89.13 100.00 New Products from JFW Industries USB Programmable Attenuator - 50P-2014 The 50P-2014 from JFW Industries is a 200-6000 MHz, solid-state variable attenuator with 0-95 dB of attenuation in 1 dB steps. It’s designed with USB control (via USB Mini-B connector), so it’s perfect for research & development labs or other flexible test environments (JFW software included or .dll file for integration into your own applications supplied upon request). Low PIM Attenuators and Terminations JFW is proud to introduce our latest innovation in RF fixed attenuation. Responding to the growth over the past several years of the need for low PIM RF components, JFW has several models of fixed attenuators and terminations that are specified at -155 dBc minimum (-165 dBc typical). They cover cellular frequencies up to 2700 MHz and are available in several standard values and power levels. Please contact the factory with your requirement. 17 JFW Industries 317-887-1340 [email protected]