H HiTRON UNIVERSAL INPUT AC

H HiTRON
UNIVERSAL INPUT AC-DC EXTERNAL DESKTOP
SWITCHING ADAPTER 60-75 WATTS GREEN POWER
SINGLE OUTPUT HEG75 SERIES
FEATURES:
 ACCOMMODATE UNIVERSAL AC INPUT
 DESKTOP IEC320-C6/C8 AC INLET
 MEET UNIVERSAL SAFETY STANDARDS
 NO LOAD POWER CONSUMPTION < 0.3W
 EMI MEET CISPR EN 55022/ FCC CLASS B
 CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Typical 90-264Vac.
Input Connector: 3 pole AC inlet IEC320-C14(DT7) /
2 pole AC inlet IEC320-C8(DT8).
Input Frequency: 47-63Hz.
Inrush Current: Typical 9.9Arms at 230Vac.
Input Current: Typical 1.23A at 115Vac, 0.67A at 230Vac.
Dielectric Withstand: Meet IEC60950-1.
EMI: Meet CISPR EN55022 / FCC Class B.
Hold-up Time: Typical 16.8mS at 115Vac,
Typical 84.8mS at 230Vac.
Over Temp. Protection: Factory set.
No Load Power: <0.3W at 230Vac.
Leakage Current: Less than 0.5mA.
LED Indicator: Optional.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typical 60-75 Watts.
Output Connector: Optional.
Line Regulation: Typical 0.1%.
Load Regulation: Typical ±5.0%.
Noise & Ripple: Typical 2% peak to peak.
OVP: Built-in by latch circuit.
Adjustability: Factory set.
Over Current Protection (OCP):
Fully protected against output overload and short circuit.
OCP is installed PCT (Peak Current Timer) for large
peak current. The PSU will shutdown after OCP is
activated in a certain period. The PSU will hiccup
if the output is in short circuit.
Consult the factory for OCP setting.
GENERAL SPECIFICATION
Efficiency: Typical 85-89%.(various with output voltage)
Switching Frequency: Typ. 60KHz.
Circuit Topology: Fixed Frequency flyback circuit.
Transient Response: Output voltage returns in less than
2mS following a 25% load change.
Safety Standard: Meet EN60950-1/ UL60950-1,
Class I for DT7L and Class II for DT8.
Power Density: 5.15-6.5Watts. / Cubic Inch.
Operating Temp.: 0 to +40 °C without derating.
(various with output voltage)
Storage Temperature: -20 to +85 °C.
Cooling: Free air convection.
Construction: Impact resistant thermo-plastic
enclosure case.
Desktop Format.
Note: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load varied from half load to full load (%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current.
(4) The typical cord is UL1185 AWG#18 or UL1571 16AWG#. The typical cord length for UL1185/AWG#18 is 2ft and for UL1571 16AWG# is 1M.
(5)The DC COM of output is connected with GND.
(6) Due to requests in market and advances in technology, specifications subject to change without notice.
For the details of safety approval, please consult the factory.
-19-
OUTPUT VOLTAGE / CURRENT RATINGS CHART
SINGLE OUTPUT(Model No. for example)
MODEL NO.
AC INLET
O/P VOLTAGE
O/P CURRENT
HEG75-S120500-7L
IEC320-C6(DT7L)
12.0Vdc
5.00A
HEG75-S120500-8
IEC320-C8(DT8)
12.0Vdc
5.00A
HEG75-S120550-7L
IEC320-C6(DT7L)
12.0Vdc
5.50A
HEG75-S120550-8
IEC320-C8(DT8)
12.0Vdc
5.50A
HEG75-S190390-7L
IEC320-C6(DT7L)
19.0Vdc
3.90A
HEG75-S190390-8
IEC320-C8(DT8)
19.0Vdc
3.90A
HEG75-S240250-7L
IEC320-C6(DT7L)
24.0Vdc
2.50A
HEG75-S240250-8
IEC320-C8(DT8)
24.0Vdc
2.50A
HEG75-S240320-7L
IEC320-C6(DT7L)
24.0Vdc
3.20A
HEG75-S240320-8
IEC320-C8(DT8)
24.0Vdc
3.20A
HEG75-S300200-7L
IEC320-C6(DT7L)
30.0Vdc
2.00A
HEG75-S300200-8
IEC320-C8(DT8)
30.0Vdc
2.00A
HEG75-S300250-7L
IEC320-C6(DT7L)
30.0Vdc
2.50A
HEG75-S300250-8
IEC320-C8(DT8)
30.0Vdc
2.50A
HEG75-S360210-7L
IEC320-C6(DT7L)
36.0Vdc
2.10A
HEG75-S360210-8
IEC320-C8(DT8)
36.0Vdc
2.10A
HEG75-S480156-7L
IEC320-C6(DT7L)
48.0Vdc
1.56A
HEG75-S480156-8
IEC320-C8(DT8)
48.0Vdc
1.56A
MECHANICAL DIMENSIONS: MM [INCHES]
-20-
WEIGHT: 324.0g (11.5 Oz.)