LAL2108-51

LAL2108-51
Broadband Access Transformer
Designed to meet UL 60950-1 and IEC 60950-1 requirements for supplementary insulation
RoHS Compliant
Operating Temperature -40°C to +85°C
Electrical Specifications @25℃
℃
OCL:
PIN 16-9= 400uH ±10% @ 10KHz/0.1V/Series (PIN 11-14 Short)
Leakage
Inductance:
PIN 16-9= 3.5uH Max. @ 100KHz/0.1V (PIN 11-14, 1,2-3,4 Short)
PIN 16-9= 2.5uH Max. @ 100KHz/0.1V (PIN 11-14, 6-7, 5-8 Short)
PIN 1-4 = 0.3 ohm Max. (PIN 1,2-3,4 Short)
PIN 5-8 = 4.4 ohm Max. (PIN 6-7 Short)
D.C.R
PIN 16-9 = 3.0 ohm Max. (PIN 11-14 Short)
PIN16-9 : PIN 1-4 = 4.25±3% :1
Turn Ratio:
T.H.D
(PIN 11-14, PIN1,2-3,4 Short)
PIN16-9 : PIN 5-8 = 1±3% :1
(PIN 11-14, PIN6-7 Short)
PIN16-9 - PIN5-8 = -82dB Max. @ 30KHz/3.162V (PIN11-14, PIN6-7 Short)
Hi-POT :
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
Dimensions
Schematic
(Units: mm, Unless otherwise specified, all tolerances are ±0.25)
LALXXXX
LinkCom
X DATE CODE G
DOT PIN1
S
Mark
1.LAL****----LAL2108
2. X----PRODUCT LINE or BLANK
3. DATE CODE----YYWW
4. G----RoHS
Ver.B