LS7338 - LSI CSI

LSI/CSI
UL
®
LS7338
LSI Computer Systems, Inc. 1235 Walt Whitman Road, Melville, NY 11747
(631) 271-0400 FAX (631) 271-0405
A3800
DELAYED-OFF LIGHT SWITCH
WITH PROGRAMMABLE ON-TIMER
FEATURES:
• Phase-Lock Loop Synchronization allows use in
Wall Switch Applications.
• Operation automatically sequences from Timed-On
to Delayed-Off to Off.
• On-Timer programmable with external R-C.
• Transition from Timed-On to Delayed Off indicated
by 31% drop in Delivered Power.
• Delayed-Off period denoted by Dim-to-Off operation.
(See Note 1)
• Control input initiates Operating Sequence
and can override Automatic Sequencing.
• 50/60Hz Line Frequency.
• +12V to +18V Operation (VSS - VDD).
• LS7338 (DIP); LS7338-S (SOIC) - See Figure 1
PIN ASSIGNMENT - TOP VIEW
SLAVE
2
V DD (-V)
3
TRIG
4
LS7338
1
LSI
SENSE
8
SYNC
7
CAP
6
OSC
5
V SS (+V)
FIGURE 1
NOTE 1: Dim-to-Off time is Mask Programmable. The standard
IC is fixed at 209 seconds for 60Hz. Dim-to-Off time can be programmed within a range of 6.5 to 836 seconds.
APPLICATIONS:
• WALL SWITCH for incandescent lighting in garage, corridor,
staircase, child’s bedroom, teenage study area.
• IN-LINE SWITCH for table lamps.
DESCRIPTION:
The LS7338 is a MOS integrated circuit designed to turn a triac On
and Off in a Power Switch for Incandescent Lighting. Activation of
SENSE or SLAVE inputs turns the triac On and starts a timer. The
triac remains On for the duration of the Timer which is controlled by
an external R-C connected to the OSCILLATOR input. When Timeout occurs, the power delivered by the triac is stepped down by 31%
and then slowly reduced to Off over a fixed period of time.
In a typical application (Figure 5), the output of the LS7338 drives
the gate of a triac in series with the load.
There are three states through which the LS7338 can be stepped.
The states and their corresponding operating mode, phase angles
and delivered power levels are shown in Table 1.
(See Figures 2 and 3)
TABLE 1
STATE 0
STATE 1
STATE 2
OPERATING MODE
OFF
Timed-On
Delayed -Off
PHASE ANGLE, ø
No Output
159˚
107˚ to 41˚
% LOAD POWER (1)
0
99
68 to 7
(1) The percentage of full power delivered to a resistive load
by the triac switch.
7338-012703-1
Jnauary 2003
OPERATING DESCRIPTION:
Upon power up, internal power-on-reset starts the LS7338 in
STATE 0. When the SENSE input transitions to logic 0, or the
SLAVE input transitions to logic 1, the IC steps to STATE 1.
When implemented as shown in the application example (Figure 5), this is accomplished by touching the appropriate Sensor
Plate. Subsequent similar transitions at SENSE or SLAVE inputs cause the LS7338 to step through the sequence:
STATE 0 --> STATE 1 --> STATE 2 --> STATE 0, etc.
STATE 1 and STATE 2 are quasi-stable states. If left in STATE
1, after a time-out period determined by the frequency set at
the OSC input (See I/O Description, Pin 6), the IC automatically
steps to STATE 2. (If the OSC input is deactivated, STATE 1
becomes stable and its OPERATING MODE is denoted as On).
When the IC steps from STATE 1 to STATE 2, the output
phase angle ø changes from 159˚ to 107˚. This corresponds to
a delivered power reduction of 31%, which causes a reduction
of lamp brightness. This brightness change provides the user
with a positive indication that the transition from STATE 1 to
STATE 2 has occurred. The Time-out period for STATE 2 is
fixed at 209 seconds for 60Hz operation. (See Note 1.)
TD1 = STATE 1 Time-out period.
TD2 = STATE 2 Time-out period.
During the STATE 2 Time-out, the TRIG phase angle ø (See
Figure 2) is ramped down from 107˚ to 41˚ in decrements of
1.4˚. When ø reaches 41˚, the IC automatically steps to STATE
0, shutting the TRIG and lamp Off.
The slow Dim-to-Off in STATE 2 gives the user a continuing reminder that Delayed-Off is operating and provides the time and
light with which to leave the area or to recycle the Light Switch.
A new operating sequence from STATE 0 can be started only by
transitions at the SENSE and SLAVE inputs.
VSS (Pin 5)
Supply voltage positive terminal.
INPUT/OUTPUT DESCRIPTION:
SENSE (Pin 1)
A logic 0 applied to this input for a minimum of three SYNC cycles, TS1 (50ms for 60Hz, 60ms for 50Hz), causes the circuit to
step to the next state in the operating sequence.
OSC (Pin 6)
An R-C network connected to this input controls the frequency of
oscillation which determines the Time-out, TD1, in State 1. T D1 is
approximately 255RC. The Oscillator is active only in State 1. Chip
to chip Oscillation Tolerance is ±10% for fixed value of RC. Tie Pin
6 to VSS if a Time-out is not desired. (See Figure 5.)
SLAVE (Pin 2)
Same description as SENSE (Pin 1) except that logic 1 replaces
logic 0. This input is designed to be used with Remote Extensions (See Figure 5 and Figure 6.)
CAP (Pin 7)
The CAP input is for external component connection for the PLL filter capacitor. (See Figure 5.)
VDD (Pin 3)
Supply voltage negative terminal.
SYNC (Pin 8)
The AC Line Frequency (50/60Hz) is applied to this input. The
Phase-Lock Loop synchronizes all internal timings to the AC signal
at the SYNC input. (See Figure 5.)
TRIG (Pin 4)
TRIG is a negative-going pulse occurring once every half cycle
of the SYNC input. Pulse width is 33µs. Table 1 in the General
Description shows values of the TRIG phase angle for the different states. (See Figure 2 and Figure 3.)
ABSOLUTE MAXIMUM RATINGS:
PARAMETER
DC supply voltage
Any input voltage
Operating temperature
Storage temperature
SYMBOL
VSS - VDD
VIN
TA
TSTG
VALUE
+20
VSS - 20 to VSS + 0.5
0 to +85
-65 to +150
UNIT
V
V
°C
°C
DC ELECTRICAL CHARACTERISTICS:
(TA = 25°C, all voltages referenced to VDD)
PARAMETER
Supply Voltage
Supply Current
SYMBOL
VSS
ISS
MIN
+12
-
TYP
1.6
MAX
+18
2.2
UNIT
V
mA
Input Voltages
SYNC Lo
SYNC Hi
SENSE Lo
SENSE Hi
SLAVE Lo
SLAVE Hi
VIRL
VIRH
VIOL
VIOH
VIVL
VIVH
0
VSS - 5.5
0
VSS - 2
0
VSS - 2
-
VSS - 9.5
VSS
VSS - 8
VSS
VSS - 8
VSS
V
V
V
V
V
V
-
IIH
-
-
110
uA
With Series 1.5MΩ
Resistor to 115VAC
SYNC, SENSE &
SLAVE Lo
IIL
-
-
100
nA
-
TRIG Hi Voltage
TRIG Lo Voltage
TRIG Sink Current
VOH
VOL
IOS
25
VSS
VSS - 8
-
-
V
V
mA
VSS = +15V
VSS = +15V,VOL = VSS - 4V
Input Current
SYNC, SENSE &
SLAVE Hi
TRANSIENT CHARACTERISTICS (See Fig. 2 and 3)
(All timings are based on Fs = 60Hz, unless otherwise specified.)
PARAMETER
SYNC Frequency
SENSE/SLAVE Sense Time
SYMBOL
Fs
Ts1
MIN
40
50
TYP
-
MAX
70
Infinite
UNIT
Hz
ms
TRIG Pulse Width
Tw
-
33
-
µs
STATE 1 Time-out period
STATE 2 Time-out period
TD1
TD2
-
255RC
209
-
s
s
7338-012703-2
CONDITIONS
VSS = +15V,
Output off
SYNC
ø
TRIG
Tw
Tw
FIGURE 2. OUTPUT CONDUCTION ANGLE, Ø
SENSE
TS1
TS1
TS1
SLAVE
<TD1
159˚/STATE 1
Ø OFF/STATE 0
<TD2
TS1
TD1
159˚/STATE 1
107˚/STATE 2
< 41˚/STATE 2
TD2
107˚/STATE 2
41˚/STATE 2
OFF/STATE 0
FIGURE 3.
7338-012703-3
SYNC
8
CAP
7
SENSE
1
SLAVE
2
BUF
OUTPUT PHASE ANGLE
PHASELOCK
LOOP
OFF/ STATE 0
ø VS
SENSE AND SLAVE
SYNC
PHASE-ANGLE
POINTER
DIGITAL
COMPARATOR
BUF
CONTROL
LOGIC
ø
DRIVER
4 TRIG
DECODE
BUF
OSC
6
V SS
5
(+V)
V DD
3
(-V)
OSC/TIMER
FIGURE 4.
LS7338 BLOCK DIAGRAM
The information included herein is believed to be
accurate and reliable. However, LSI Computer Systems,
Inc. assumes no responsibilities for inaccuracies, nor for
any infringements of patent rights of others which may
result from its use.
FIGURE 5. A TYPICAL LIGHT SWITCH APPLICATION
SEE NOTE 2
P
P
C7
R6
G
R10
EXTN
MT1
T1
-
Z1
ELECTRONIC
EXTENSION
(Figure 6)
C3
SEE NOTE
3
D1
L1
AC
MAINS
R9
+
MT2
R4
C1
4
C2
3
1
2
R3
SENSOR
PLATE
OUT V DD SLV S E N S E
R7
LS7338
R1
V SS OSC CAP SYNC
5
6
7
8
R2
A
C3
B
LOAD
SEE NOTE 1
C4
R5
R8
-
N
+
C6
NOTES:
1. Use Connection A when Neutral is not available.
Use Connection B when Neutral is available.
2. C7 is used only with Electronic Extension.
R10 is used only with Pushbutton Switch.
3. Connection between Pin 2 and Pin 3 is removed
when SLAVE input is used.
4. See Table 2 for Component Functional Description
TABLE 2 .
FIGURE 5 COMPONENT FUNCTIONAL DESCRIPTION
COMPONENTS
(1) R1
(2) R1
R2
R3
R4
(3) R5
R6
R7
R8
R9
R10
C1
115VAC
270Ω, 1W
82Ω
1.5MΩ
2.7MΩ
2.7MΩ
1MΩ to 5MΩ
100Ω
(4)
(4)
1.5MΩ
150kΩ
0.15µF, 200V
220VAC
1kΩ, 2W
(1)
82Ω
(2)
1.5MΩ
4.7MΩ
4.7MΩ
1MΩ to 5MΩ
100Ω
(4)
(4)
1.5MΩ
150kΩ
(6)
0.15µF, 400V
C2
C2
C3
C4
C5
C6
C7
Z1
D1
L1
T1
115VAC
0.33µF, 200V
0.22µF, 200V
47µF
470pF
0.047µF
(5)
0.1µF, 200V
15V, 1/2W
1N4148
100µH
Q4008L4
220VAC
0.22µF, 400V
0.1µF, 400V
47µF
470pF
0.047µF
(5)
0.1µF, 400V
15V, 1/2W
1N4148
200µH
Q5004L4
FUNCTIONAL DESCRIPTION
Z1, D1, R1,
C2, C3
DC Power Supply.
R2, C4
Current limit and filter AC for SYNC input.
C1, L1
RFI filtering for AC Mains.
C5
PLL filter capacitor.
(1) Connection A (2) Connection B (3) Select for desired touch sensitivity
(4) 100kΩ ≤ (R7 + R8) ≤ 10MΩ (5) (R7 + R8)C6 ≥ 5ms (6) Typical
All Resistors 1/4W, all Capacitors 25V unless otherwise specified
SENSOR PLATE
2MΩ ,1/4W
EXTN
R3, R4, R5
Network sets the Touch Sensitivity
for the SENSE input.
R6
Current limiting and isolation between
I C output and Triac Gate.
R7, R8, C6
Oscillator R-C network.
Potentiometer R6 required only if providing
user adjustment of Time-out, TD1.
R9, C7
Filter for the Electronic Extension
R10
Current limiting resistor for
the Pushbutton Switch Extension.
2KΩ ,1/4W
IN914
2MΩ ,1/4W
MPS8599
200K Ω ,1/4W
P
FIGURE 6. ELECTRONIC SWITCH EXTENSION
7338-012703-4
EXTENSIONS: (See Figure 5 and Figure 6)
All sequence functions can also be inplemented by utilizing the
SLAVE input. This can be done by either a pushbutton switch
or the electronic switch in conjunction with a sensing plate as
shown in Figure 6. When the plate is touched, a logic high level
is generated at the EXTENSION terminal for both half cycles of
the line frequency.