Cost-Effective A/D 8-Bit OTP MCU HT46R002/HT46R003 Revision: V1.10 Date: ��������������� August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Table of Contents Features............................................................................................................. 5 CPU Features.......................................................................................................................... 5 Peripheral Features.................................................................................................................. 5 General Description ......................................................................................... 5 Selection Table.................................................................................................. 6 Block Diagram................................................................................................... 6 Pin Assignment................................................................................................. 6 Pin Description................................................................................................. 7 HT46R002................................................................................................................................ 7 HT46R003................................................................................................................................ 8 Absolute Maximum Ratings............................................................................. 8 D.C.Characteristics........................................................................................... 9 A.C. Characteristics.......................................................................................... 9 A/D Converter Characteristics....................................................................... 10 Power-on Reset Characteristics.................................................................... 10 System Architecture........................................................................................11 Clocking and Pipelining...........................................................................................................11 Program Counter – PC........................................................................................................... 12 Stack...................................................................................................................................... 12 Arithmetic and Logic Unit – ALU............................................................................................ 13 Program Memory............................................................................................ 13 Structure................................................................................................................................. 13 Special Vectors...................................................................................................................... 14 Look-up Table......................................................................................................................... 14 Table Program Example......................................................................................................... 15 RAM Data Memory.......................................................................................... 16 Structure................................................................................................................................. 16 Special Purpose Data Memory.............................................................................................. 17 Special Function Registers............................................................................ 18 Indirect Addressing Registers – IAR0, IAR1.......................................................................... 18 Memory Pointers – MP0, MP1............................................................................................... 18 Accumulator – ACC................................................................................................................ 19 Program Counter Low Register – PCL................................................................................... 19 Status Register – STATUS..................................................................................................... 19 System Control Registers – CTRL0, CTRL1.......................................................................... 21 Rev. 1.10 2 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Oscillator......................................................................................................... 22 System Oscillator Overview................................................................................................... 22 System Clock Configurations................................................................................................. 22 Internal RC Oscillator – HIRC................................................................................................ 22 Internal 12kHz Oscillator – LIRC............................................................................................ 22 Power Down Mode and Wake-up................................................................... 23 Power Down Mode................................................................................................................. 23 Entering the Power Down Mode............................................................................................ 23 Standby Current Considerations............................................................................................ 23 Wake-up................................................................................................................................. 24 Watchdog Timer.............................................................................................. 25 Watchdog Timer Clock Source............................................................................................... 25 Watchdog Timer Control Registers........................................................................................ 25 Watchdog Timer Operation.................................................................................................... 26 Reset and Initialization................................................................................... 27 Reset Functions..................................................................................................................... 27 Reset Initial Conditions.......................................................................................................... 30 Input/Output Ports.......................................................................................... 33 Pull-high Resistors................................................................................................................. 33 Port A Wake-up...................................................................................................................... 34 I/O Port Control Registers...................................................................................................... 35 Pin-shared Functions............................................................................................................. 36 I/O Pin Structures................................................................................................................... 37 Programming Considerations................................................................................................. 38 Timer/Event Counter...................................................................................... 39 Configuring the Timer/Event Counter Input Clock Source..................................................... 39 Timer Register – TMR0.......................................................................................................... 40 Timer Control Register – TMR0C........................................................................................... 40 Timer Mode............................................................................................................................ 41 Event Counter Mode.............................................................................................................. 42 Pulse Width Capture Mode.................................................................................................... 43 Prescaler................................................................................................................................ 44 PFD Function (for HT46R003)............................................................................................... 44 I/O Interfacing......................................................................................................................... 44 Programming Considerations................................................................................................. 45 Timer Program Example........................................................................................................ 46 Pulse Width Modulator................................................................................... 47 PWM Operation...................................................................................................................... 47 6+2 PWM Mode..................................................................................................................... 47 7+1 PWM Mode..................................................................................................................... 48 PWM Output Control.............................................................................................................. 49 Rev. 1.10 3 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Analog to Digital Converter .......................................................................... 50 A/D Overview......................................................................................................................... 50 A/D Converter Data Registers – ADRL, ADRH...................................................................... 50 A/D Converter Control Registers – ADCR, ACSR.................................................................. 51 A/D Operation........................................................................................................................ 52 A/D Converter On/Off Control................................................................................................ 53 A/D Input Pins........................................................................................................................ 53 Summary of A/D Conversion Steps........................................................................................ 54 Programming Considerations................................................................................................. 55 A/D Transfer Function............................................................................................................ 55 A/D Programming Example.................................................................................................... 56 Interrupts......................................................................................................... 58 Interrupt Register................................................................................................................... 58 Interrupt Operation................................................................................................................. 59 Interrupt Priority...................................................................................................................... 60 External Interrupt.................................................................................................................... 61 Timer/Event Counter Interrupt................................................................................................ 61 A/D Converter Interrupt.......................................................................................................... 61 Interrupt Wake-up Function.................................................................................................... 62 Programming Considerations................................................................................................. 62 Application Circuits........................................................................................ 62 Instruction Set................................................................................................. 63 Introduction............................................................................................................................ 63 Instruction Timing................................................................................................................... 63 Moving and Transferring Data................................................................................................ 63 Arithmetic Operations............................................................................................................. 63 Logical and Rotate Operation................................................................................................ 64 Branches and Control Transfer.............................................................................................. 64 Bit Operations........................................................................................................................ 64 Table Read Operations.......................................................................................................... 64 Other Operations.................................................................................................................... 64 Instruction Set Summary............................................................................... 65 Table Conventions.................................................................................................................. 65 Instruction Definition...................................................................................... 67 Package Information...................................................................................... 76 8-pin DIP (300mil) Outline Dimensions.................................................................................. 77 8-pin SOP (150mil) Outline Dimensions................................................................................ 78 10-pin MSOP Outline Dimensions......................................................................................... 79 16-pin DIP (300mil) Outline Dimensions................................................................................ 80 16-pin NSOP (150mil) Outline Dimensions............................................................................ 82 Rev. 1.10 4 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Note that 8-pin MCU package types are not marketed in the following countries: USA, UK, Germany, The Netherlands, France and Italy. Features CPU Features • Operating voltage: fSYS=8MHz: 2.3V~5.5V • Up to 0.5μs instruction cycle with 8MHz system clock at VDD=5V • Power down and wake-up functions to reduce power consumption • Two oscillators: ♦♦ Internal high speed RC -- HIRC ♦♦ Internal low speed RC -- LIRC • Fully integrated internal 8MHz oscillator requires no external components • All instructions executed in one or two instruction cycles • Table read instruction • 61 powerful instructions • 2-level subroutine nesting • Bit manipulation instruction Peripheral Features • Program Memory: 1K×14 • RAM Data Memory: 64×8 • Watchdog Timer function • Up to 14 bidirectional I/O lines • 4 channel 12-bit ADC • 1 channel 8-bit PWM • External interrupt pin shared with I/O pin • One 8-bit programmable Timer/Event Counter with overflow interrupt and prescaler • Low voltage reset function • Programmable Frequency Divider – PFD • Package types: 8-pin DIP/SOP, 10-pin MSOP and 16-pin DIP/NSOP General Description The devices are 8-bit high performance RISC architecture microcontroller devices specifically designed for a wide range of applications. The advantages of low power consumption, I/O flexibility, timer functions, oscillator options, HALT and wake-up functions, watchdog timer, as well as low cost, enhance the versatility of these devices to suit for a wide range of the I/O and A/D control application possibilities such as industrial control, consumer products and subsystem controllers, etc. Rev. 1.10 5 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Selection Table Part No. Operating Voltage ROM RAM I/O HIRC 8-bit Interrupt (MHz) Timer Ext. Int. A/D PWM PFD Stack Package 8 8 1 1 2 12-bit×4 1 × 2 8DIP/SOP 10MSOP HT46R003 2.3V~5.5V 1K×14 64×8 14 8 1 1 2 12-bit×4 1 √ 2 16DIP/NSOP P�5/�N3 HT46R002 2.3V~5.5V 1K×14 64×8 Block Diagram Note: Only the HT46R003 has a PFD function. Pin Assignment VDD 1 8 VSS P�6 � 7 P�0/PWM/�N0 P�5/�N3 3 6 P�1/TMR/�N1 P�7/RES � 5 P��/INT/�N� HT46R002 8 DIP-A/SOP-A 1 16 PC5 � 15 P�6/PFD PC� 3 1� P�7/RES VDD 1 10 VSS PC3 � 13 � 9 P�0/PWM/�N0 VDD P�6 PC� 5 1� 3 8 P�1/TMR/�N1 VSS P�5/�N3 PC1 6 11 P�0/PWM/�N0 P�7/RES � 7 P��/INT/�N� 7 10 P�1/TMR/�N1 P�� 5 6 P�3 PC0 P�3 8 9 P��/INT/�N� HT46R003 16 DIP-A/NSOP-A HT46R002 10 MSOP-A Rev. 1.10 P�� 6 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Pin Description HT46R002 Pin Name PA0/PWM/AN0 PA1/TMR/AN1 PA2/INT/AN2 PA3~PA4 PA5/AN3 PA6 Function OPT I/T PA0 PAPU PAWU O/T ST CMOS General purpose I/O. Register enabled pull-up and wake-up. PWM CTRL0 — CMOS PWM output AN0 ADCR AI PA1 PAPU PAWU ST TMR TMR0C ST — Timer/Event counter 0 input AN1 ADCR AI — Analog input channel 1 PA2 PAPU PAWU ST INT INTC0 CTRL1 ST — Description Analog input channel 0 CMOS General purpose I/O. Register enabled pull-up and wake-up. CMOS General purpose I/O. Register enabled pull-up and wake-up. — External interrupt input — Analog input channel 2 AN2 ADCR AI PA3~PA4 PAPU ST CMOS General purpose I/O. Register enabled pull-up. PA5 PAPU PAWU ST CMOS General purpose I/O. Register enabled pull-up and wake-up. AN3 ADCR AI PA6 PAPU ST CMOS General purpose I/O. Register enabled pull-up. NMOS General purpose I/O. — Analog input channel 3 PA7 PAPU ST RES — ST — Reset input VDD VDD — PWR — Power supply VSS VSS — PWR — Ground PA7/RES Note: OPT: Optional by register option AI: Analog signal input I/T: Input type O/T: Output type ST: Schmitt Trigger input CMOS: CMOS output NMOS: NMOS output PWR: Power Rev. 1.10 7 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU HT46R003 Pin Name PA0/PWM/AN0 PA1/TMR/AN1 PA2/INT/AN2 PA3~PA4 PA5/AN3 PA6/PFD PA7/RES Function OPT I/T PA0 PAPU PAWU O/T ST CMOS General purpose I/O. Register enabled pull-up and wake-up. PWM CTRL0 — CMOS PWM output AN0 ADCR AI PA1 PAPU PAWU ST TMR TMR0C ST — Timer/Event counter 0 input AN1 ADCR AI — Analog input channel 1 PA2 PAPU PAWU ST INT INTC0 CTRL1 ST — Description Analog input channel 0 CMOS General purpose I/O. Register enabled pull-up and wake-up. CMOS General purpose I/O. Register enabled pull-up and wake-up. — External interrupt input — Analog input channel 2 AN2 ADCR AI PA3~PA4 PAPU ST CMOS General purpose I/O. Register enabled pull-up. PA5 PAPU PAWU ST CMOS General purpose I/O. Register enabled pull-up and wake-up. AN3 ADCR AI PA6 PAPU ST PFD CTRL0 ST PA7 PAPU ST — Analog input channel 3 CMOS General purpose I/O. Register enabled pull-up. — PFD output NMOS General purpose I/O. RES — ST PC0~PC5 PCPU ST VDD VDD — PWR — Power supply VSS VSS — PWR — Ground PC0~PC5 — Reset input CMOS General purpose I/O. Register enabled pull-up. Note: OPT: Optional by register option; AI: Analog signal input I/T: Input type; O/T: Output type; ST: Schmitt Trigger input; CMOS: CMOS output; NMOS: NMOS output PWR: Power Absolute Maximum Ratings Supply Voltage.................................................................................................VSS−0.3V to VSS+6.0V Input Voltage...................................................................................................VSS−0.3V to VDD+0.3V Storage Temperature.....................................................................................................-50˚C to 125˚C Operating Temperature...................................................................................................-40˚C to 85˚C Note: These are stress ratings only. Stresses exceeding the range specified under "Absolute Maximum Ratings" may cause substantial damage to these devices. Functional operation of these devices at other conditions beyond those listed in the specification is not implied and prolonged exposure to extreme conditions may affect devices reliability. Rev. 1.10 8 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU D.C.Characteristics Ta=25°C Symbol VDD IDD1 ISTB1 Parameter Operating Voltage (HIRC) Operating Current (HIRC on) Standby Current (LIRC on) Test Conditions VDD ─ 3V 5V 3V 5V 3V Conditions fSYS=8MHz No load, fSYS=8MHz No load, system HALT Typ. Max. Unit 2.3 ─ 5.5 V ─ 1.2 1.8 mA ─ 2.4 3.6 mA ─ ─ 5 μA ─ ─ 10 μA ─ ─ 1 μA ─ ─ 2 μA 0 ─ 1.5 V 0 ─ 0.2VDD V 3.5 ─ 5 V 0.8VDD ─ VDD V ISTB2 Standby Current (LIRC off) VIL1 Input Low Voltage for I/O Ports, TMR and INT pin 5V VIH1 Input High Voltage for I/O Ports, TMR and INT pin 5V VIL2 Input low voltage (RES) ─ ─ 0 ─ 0.4VDD V VIH2 Input high voltage (RES) ─ ─ 0.9VDD ─ VDD V VLVR Low Voltage Reset Voltage ─ 2.0 2.1 2.2 V -2.5 -5 ─ mA IOH I/O source current (PA) IOL1 I/O sink current (PA) IOL2 PA7 sink current RPH Pull-high Resistance for I/O Ports 5V No load, system HALT Min. ─ ─ ─ ─ 3V 5V 3V 5V 5V LVR Enable, 2.1V VOH=0.9VDD VOL=0.1VDD VOL=0.1VDD -5 -11 ─ mA 7.5 15 ─ mA 15 30 ─ mA 2 3 ─ mA 3V ─ 20 60 100 kΩ 5V ─ 10 30 50 kΩ A.C. Characteristics Ta=25°C Symbol fCPU fHIRC fTIMER Parameter Operating Clock System Clock (HIRC) Timer I/P Frequency (TMR) Test Conditions VDD Conditions ─ 2.3V~5.5V Min. Typ. Max. Unit 8 8 8 MHz 3/5V ─ -2% 8 +2% MHz 3/5V Ta=0°~70°C -5% 8 +5% MHz 3.0~5.5V Ta=0°~70°C -8% 8 +8% MHz 3.0~5.5V Ta=-40°~85°C -12% 8 +12% MHz 3.3~5.5V ─ 0 ─ 8 MHz 3V ─ 45 90 180 μs 5V ─ 32 65 130 μs ─ 1 ─ ─ μs ─ 16 ─ tSYS tWDTOSC Watchdog oscillator period tRES External reset low pulse width ─ tSST System start-up timer period ─ tLVR Low Voltage Width to Reset ─ ─ 0.25 1 2 ms tRSTD System Reset Delay Time (All Reset) ─ ─ 25 50 100 ms wake-up from halt Note: 1. tSYS=1/fSYS 2. To maintain the accuracy of the internal HIRC oscillator frequency, a 0.1μF decoupling capacitor should be connected between VDD and VSS and located as close to the device as possible. Rev. 1.10 9 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU A/D Converter Characteristics Ta=25°C Symbol Test Conditions Parameter AVDD Analog operating voltage — VAD AD Input Voltage — 2.7V DNL Min. Typ. 2.7 0 VREF=VDD=AVDD tAD=0.5μs VREF=VDD=AVDD tAD=0.5μs VDD A/D Differential Non-linearity 3V 5V 2.7V 3V Conditions VREF=VDD — INL A/D Integral non-linearity IADC Additional Power Consumption if A/D Converter is Used tAD A/D Converter Clock Period tADC A/D Conversion Time 2.7V~5.5V 12-bit ADC (Include Sample and Hold Time) tON2ST A/D Converter On-to-Start Time 5V 3V 5V No load (tAD=0.5μs ) 2.7V~5.5V — 2.7V~5.5V — Max. Unit — 5.5 V — AVDD/VREF V -2 — +2 LSB -4 — +4 LSB — 0.5 — mA — 0.6 — mA 0.5 — 10 μs — 16 — tAD 2 — — μs Note: ADC conversion time (tAD)=n (bits ADC) + 4 (sampling time), the conversion for each bit needs one ADC clock (tAD). Power-on Reset Characteristics Ta=25°C Symbol Test Conditions Parameter VDD Conditions Min. Typ. Max. Unit VPOR VDD Start Voltage to Ensure Power-on Reset ─ ─ ─ ─ 100 mV RRVDD VDD Raising Rate to Ensure Power-on Reset ─ ─ 0.035 ─ ─ V/ms tPOR Minimum Time for VDD Stays at VPOR to Ensure Power-on Reset ─ ─ 1 ─ ─ ms VDD tPOR RRVDD VPOR Rev. 1.10 10 Time August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU System Architecture A key factor in the high-performance features of the Holtek range of microcontrollers is attributed to the internal system architecture. The range of devices take advantage of the usual features found within RISC microcontrollers providing increased speed of operation and enhanced performance. The pipelining scheme is implemented in such a way that instruction fetching and instruction execution are overlapped, hence instructions are effectively executed in one cycle, with the exception of branch or call instructions. An 8-bit wide ALU is used in practically all operations of the instruction set. It carries out arithmetic operations, logic operations, rotation, increment, decrement, branch decisions, etc. The internal data path is simplified by moving data through the Accumulator and the ALU. Certain internal registers are implemented in the Data Memory and can be directly or indirectly addressed. The simple addressing methods of these registers along with additional architectural features ensure that a minimum of external components is required to provide a functional I/O and A/D system with maximum reliability and flexibility. Clocking and Pipelining The main system clock, derived from HIRC oscillator is subdivided into four internally generated non-overlapping clocks, T1~T4.The Program Counter is incremented at the beginning of the T1 clock during which time a new instruction is fetched. The remaining T2~T4 clocks carry out the decoding and execution functions. In this way, one T1~T4 clock cycle forms one instruction cycle. Although the fetching and execution of instructions takes place in consecutive instruction cycles, the pipelining structure of the microcontroller ensures that instructions are effectively executed in one instruction cycle. The exception to this are instructions where the contents of the Program Counter are changed, such as subroutine calls or jumps, in which case the instruction will take one more instruction cycle to execute. System Clocking and Pipelining For instructions involving branches, such as jump or call instructions, two instruction cycles are required to complete instruction execution. An extra cycle is required as the program takes one cycle to firstly obtain the actual jump or call address and then another cycle to actually execute the branch. The requirement for this extra cycle should be taken into account by programmers in timing sensitive applications. Instruction Fetching Rev. 1.10 11 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Program Counter – PC During program execution, the Program Counter is used to keep track of the address of the next instruction to be executed. It is automatically incremented by one each time an instruction is executed except for instructions, such as “JMP” or “CALL” that demand a jump to a nonconsecutive Program Memory address. It must be noted that only the lower 8 bits, known as the Program Counter Low Register, are directly addressable by user. When executing instructions requiring jumping to non-consecutive addresses such as a jump instruction, a subroutine call, interrupt or reset, etc, the microcontroller manages program control by loading the required address into the Program Counter. For conditional skip instructions, once the condition has been met, the next instruction, which has already been fetched during the present instruction execution, is discarded and a dummy cycle takes its place while the correct instruction is obtained. Program Counter High Byte of Program Low Byte of Program PC9, PC8 PCL7~PCL0 The lower byte of the Program Counter, known as the Program Counter Low register or PCL, is available for program control and is a readable and writeable register. By transferring data directly into this register, a short program jump can be executed directly. However, as only this low byte is available for manipulation, the jumps are limited in the present page of memory, which have 256 locations. When such program jumps are executed it should also be noted that a dummy cycle will be inserted. The lower byte of the Program Counter is fully accessible under program control. Manipulating the PCL might cause program branching, so an extra cycle is needed to pre-fetch. Stack This is a special part of the memory which is used to save the contents of the Program Counter only. The stack is organized into 2 levels and neither part of the data nor part of the program space, and is neither readable nor writeable. The activated level is indexed by the Stack Pointer, and is neither readable nor writeable. At a subroutine call or interrupt acknowledge signal, the contents of the Program Counter are pushed onto the stack. At the end of a subroutine or an interrupt routine, signaled by a return instruction, RET or RETI, the Program Counter is restored to its previous value from the stack. After a device reset, the Stack Pointer will point to the top of the stack. P ro g ra m C o u n te r T o p o f S ta c k S ta c k L e v e l 1 S ta c k P o in te r S ta c k L e v e l 2 B o tto m P ro g ra m M e m o ry o f S ta c k If the stack is full and an enabled interrupt takes place, the interrupt request flag will be recorded but the acknowledge signal will be inhibited. When the Stack Pointer is decremented, by RET or RETI, the interrupt will be serviced. This feature prevents stack overflow allowing the programmer to use the structure more easily. However, when the stack is full, a CALL subroutine instruction can still be executed which will result in a stack overflow. Precautions should be taken to avoid such cases which might cause unpredictable program branching. Rev. 1.10 12 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Arithmetic and Logic Unit – ALU The arithmetic-logic unit or ALU is a critical area of the microcontroller that carries out arithmetic and logic operations of the instruction set. Connected to the main microcontroller data bus, the ALU receives related instruction codes and performs the required arithmetic or logical operations after which the result will be placed in the specified register. As these ALU calculation or operations may result in carry, borrow or other status changes, the status register will be correspondingly updated to reflect these changes. The ALU supports the following functions: • Arithmetic operations: ADD, ADDM, ADC, ADCM, SUB, SUBM, SBC, SBCM, DAA • Logic operations: AND, OR, XOR, ANDM, ORM, XORM, CPL, CPLA • Rotation RRA, RR, RRCA, RRC, RLA, RL, RLCA, RLC • Increment and Decrement INCA, INC, DECA, DEC • Branch decision, JMP, SZ, SZA, SNZ, SIZ, SDZ, SIZA, SDZA, CALL, RET, RETI. Program Memory The Program Memory is the location where the user code or program is stored. The device is supplied with One-Time Programmable, OTP, memory where users can program their application code into the device. By using the appropriate programming tools, OTP devices offer users the flexibility to freely develop their applications which may be useful during debug or for products requiring frequent upgrades or program changes. Structure The Program Memory has a capacity of 1K×14 bits. The Program Memory is addressed by the Program Counter and also contains data, table information and interrupt entries information. Table data, which can be set in any location within the Program Memory, is addressed by separate table pointer registers. Program Memory Structure Rev. 1.10 13 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Special Vectors Within the Program Memory, certain locations are reserved for the reset and interrupts. Reset Vector This vector is reserved for use by the device reset for program initialization. After a device reset is initiated, the program will jump to this location and begin execution. External interrupt vector This vector is used by the external interrupt. If the external interrupt pin on the device receives an edge transition, the program will jump to this location and begin execution if the external interrupt is enabled and the stack is not full. The external interrupt active edge transition type, whether high to low, low to high or both is specified in the CTRL1 register. Timer/Event counter 0 interrupt vector This internal vector is used by the Timer/Event Counter 0. If a Timer/Event Counter overflow occurs, the program will jump to its respective location and begin execution if the associated Timer/ Event Counter 0 interrupt is enabled and the stack is not full. A/D interrupt vector This internal vector is used by the A/D converter. If A/D conversion complete, the program will jump to this location and begin execution if the A/D interrupt is enabled and the stack is not full. Look-up Table Any location within the Program Memory can be defined as a look-up table where programmers can store fixed data. To use the look-up table, the table pointer must first be set by placing the address of the look up data to be retrieved in the table pointer register, TBLP. This register defines the total address of the look-up table. After setting up the table pointer, the table data can be retrieved from the Program Memory using the “TABRDC [m]” or “TABRDL [m]” instructions, respectively. When the instruction is executed, the lower order table byte from the Program Memory will be transferred to the user defined Data Memory register [m] as specified in the instruction. The higher order table data byte from the Program Memory will be transferred to the TBLH special register. Any unused bits in this transferred higher order byte will be read as “0”. The accompanying diagram illustrates the addressing data flow of the look-up table. Rev. 1.10 14 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Table Program Example The accompanying example shows how the table pointer and table data is defined and retrieved from the device. This example uses raw table data located in the last page which is stored there using the ORG statement. The value at this ORG statement is “0300H” which refers to the start address of the last page within the 1K Program Memory of the microcontroller. The table pointer is set here to have an initial value of “06H”. This will ensure that the first data read from the data table will be at the Program Memory address “0306H” or 6 locations after the start of the last page. Note that the value for the table pointer is referenced to the first address of the present page if the “TABRDC [m]” instruction is being used. The high byte of the table data which in this case is equal to zero will be transferred to the TBLH register automatically when the “TABRDL [m]” instruction is executed. Because the TBLH register is a read-only register and cannot be restored, care should be taken to ensure its protection if both the main routine and Interrupt Service Routine use the table read instructions. If using the table read instructions, the Interrupt Service Routines may change the value of TBLH and subsequently cause errors if used again by the main routine. As a rule it is recommended that simultaneous use of the table read instructions should be avoided. However, in situations where simultaneous use cannot be avoided, the interrupts should be disabled prior to the execution of any main routine table-read instructions. Note that all table related instructions require two instruction cycles to complete their operation. Instruction Table Location Bits b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 TABRDC [m] @9 @8 @7 @6 @5 @4 @3 @2 @1 @0 TABRDL [m] 1 1 @7 @6 @5 @4 @3 @2 @1 @0 Table Location Note: PC9~PC8: Current program Counter bits @7~@0: Table Pointer TBLP bits Table Read Program Example tempreg1 db? ; temporary register #1 tempreg2 db? ; temporary register #2 : : mov a,06h ; initialize table pointer - note that this address is referenced mov tblp, a ; to the last page or present page : : tabrdl tempreg1 ; transfers value in table referenced by table pointer ; to tempreg1 ; data at prog. memory address “0306H” transferred to ; to tempreg1 and TBLH dec tblp ; reduce value of table pointer by one tabrdl tempreg2 ; transfers value in table referenced by table pointer ; to tempreg2 ; data at prog. memory address “0305H” transferred to ; tempreg2 and TBLH ; in this example the data “1AH” is transferred to tempreg1 and ; data “0FH” to register tempreg2 the value “00H” will be ; transferred to the high byte register TBLH : : org 0300h ; sets initial address of last page dc 00Ah, 00Bh, 00Ch, 00Dh, 00Eh, 00Fh, 01Ah, 01Bh : : Rev. 1.10 15 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU RAM Data Memory The Data Memory is a volatile area of 8-bit wide RAM internal memory and is the location where temporary information is stored. Structure Divided into two sections, the first of these is an area of RAM where special function registers are located. These registers have fixed locations and are necessary for correct operation of the device. Many of these registers can be read from and written to directly under program control, however, some remain protected from user manipulation. The second area of Data Memory is reserved for general purpose use. All locations within this area are read and write accessible under program control. The two sections of Data Memory, the Special Purpose and General Purpose Data Memory are located at consecutive locations. All are implemented in RAM and are 8 bits wide but the length of each memory section is dictated by the type of microcontroller chosen. The start address of the Data Memory for all devices is the address “00H”. All microcontroller programs require an area of read/write memory where temporary data can be stored and retrieved for use later. It is this area of RAM memory that is known as General Purpose Data Memory. This area of Data Memory is fully accessible by the user program for both reading and writing operations. By using the “SET [m].i” and “CLR [m].i” instructions individual bits can be set or reset under program control giving the user a large range of flexibility for bit manipulation in the Data Memory. Data Memory Structure Note: Most of the Data Memory bits can be directly manipulated using the “SET [m].i” and “CLR [m].i” with the exception of a few dedicated bits. The Data Memory can also be accessed via the memory pointer registers. Rev. 1.10 16 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Special Purpose Data Memory This area of Data Memory is where registers, necessary for the correct operation of the microcontroller, are stored. Most of the registers are both readable and writeable but some are protected and are readable only, the details of which are located under the relevant Special Function Register section. Note that for locations that are unused, any read instruction to these addresses will return the value “00H”. Special Purpose Data Memory Rev. 1.10 17 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Special Function Registers To ensure successful operation of the microcontroller, certain internal registers are implemented in the Data Memory area. These registers ensure correct operation of internal functions such as timer, interrupts, etc., as well as external functions such as I/O data control. The locations of these registers within the Data Memory begin at the address of “00H”. Any unused Data Memory locations between these special function registers and the point where the General Purpose Memory begins is reserved and attempting to read data from these locations will return a value of “00H”. Indirect Addressing Registers – IAR0, IAR1 The Indirect Addressing Registers, IAR0 and IAR1, although having their locations in normal RAM register, do not actually physically exist as normal registers. The method of indirect addressing for RAM data manipulation is using these Indirect Addressing Registers and Memory Pointers, in contrast to direct memory addressing, where the actual memory address is specified. Actions on the IAR0 and IAR1 registers will result in no actual read or write operation to these registers but rather to the memory location specified by their corresponding Memory Pointers, MP0 or MP1. As the Indirect Addressing Registers are not physically implemented, reading the Indirect Addressing Registers indirectly will return a result of “00H” and writing to the registers indirectly will result in no operation. Memory Pointers – MP0, MP1 Two Memory Pointers, known as MP0 and MP1 are provided. These Memory Pointers are physically implemented in the Data Memory and can be manipulated in the same way as normal registers providing a convenient way with which to indirectly address and track data. When any operation to the relevant Indirect Addressing Registers is carried out, the actual address which the microcontroller is directed to is the address specified by the related Memory Pointer. Note that for this device, the Memory Pointers, MP0 and MP1, are both 8-bit registers and used to access the Data Memory together with their corresponding indirect addressing registers IAR0 and IAR1. The following example shows how to clear a section of four Data Memory locations already defined as locations adres1 to adres4. Indirect Addressing Program Example data . section ‘data’ adres1 db ? adres2 db ? adres3 db ? adres4 db ? block db ? code. section at 0 code org 00h start: mov a,04h; mov block,a mov a,offset adres1 ; mov mp0,a ; loop: clr IAR0 ; inc mp0; sdz block; jmp loop continue: set size of block Accumulator loaded with first RAM address set memory pointer with first RAM address clear the data at address defined by MP0 increment memory pointer check if last memory location has been cleared The important point to note here is that in the example shown above, no reference is made to specific Data Memory addresses. Rev. 1.10 18 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Accumulator – ACC The Accumulator is central to the operation of any microcontroller and is closely related with operations carried out by the ALU. The Accumulator is the place where all intermediate results from the ALU are stored. Without the Accumulator it would be necessary to write the result of each calculation or logical operation such as addition, subtraction, shift, etc., to the Data Memory resulting in higher programming and timing overheads. Data transfer operations usually involve the temporary storage function of the Accumulator; for example, when transferring data between one user-defined register and another, it is necessary to do this by passing the data through the Accumulator as no direct transfer between two registers is permitted. Program Counter Low Register – PCL To provide additional program control functions, the low byte of the Program Counter is made accessible to programmers by locating it within the Special Purpose area of the Data Memory. By manipulating this register, direct jumps to other program locations are easily implemented. Loading a value directly into this PCL register will cause a jump to the specified Program Memory location, however as the register is only 8-bit wide only jumps within the current Program Memory page are permitted. When such operations are used, note that a dummy cycle will be inserted. Status Register – STATUS This 8-bit register contains the zero flag (Z), carry flag (C), auxiliary carry flag (AC), overflow flag (OV), power down flag (PDF), and watchdog time-out flag (TO). These arithmetic/logical operation and system management flags are used to record the status and operation of the microcontroller. With the exception of the TO and PDF flags, bits in the status register can be altered by instructions like most other registers. Any data written into the status register will not change the TO or PDF flag. In addition, operations related to the status register may give different results due to the different instruction operations. The TO flag can be affected only by a system power-up, a WDT time-out or by executing the “CLR WDT” or “HALT” instruction. The PDF flag is affected only by executing the “HALT” or “CLR WDT” instruction or during a system power-up. The Z, OV, AC and C flags generally reflect the status of the latest operations. In addition, on entering an interrupt sequence or executing a subroutine call, the status register will not be pushed onto the stack automatically. If the contents of the status registers are important and if the subroutine can corrupt the status register, precautions must be taken to correctly save it. Note that bits 0~3 of the STATUS register are both readable and writeable bits. Rev. 1.10 19 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU STATUS Register Bit 7 6 5 4 3 2 1 0 Name — — TO PDF OV Z AC C R/W — — R/W R/W R/W R/W R/W R/W POR — — 0 0 x x x x “x”: unknown Bit 7~6 Unimplemented, read as “0” Bit 5TO: Watchdog Time-Out flag 0: After power up or executing the “CLR WDT” or “HALT” instruction 1: A watchdog time-out occurred Bit 4PDF: Power down flag 0: After power up or executing the “CLR WDT” instruction 1: By executing the “HALT” instruction Bit 3OV: Overflow flag 0: No overflow 1: An operation results in a carry into the highest-order bit but not a carry out of the highest-order bit or vice versa Bit 2Z: Zero flag 0: The result of an arithmetic or logical operation is not zero 1: The result of an arithmetic or logical operation is zero Bit 1AC: Auxiliary flag 0: No auxiliary carry 1: An operation results in a carry out of the low nibbles in addition, or no borrow from the high nibble into the low nibble in subtraction Bit 0C: Carry flag 0: No carry out 1: An operation results in a carry during an addition operation or if a borrow does not take place during a subtraction operation C is also affected by a rotate through carry instruction. Rev. 1.10 20 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU System Control Registers – CTRL0, CTRL1 These registers are used to provide control internal functions such as the PFD function, the PWM function and external interrupt edge trigger type selection. CTRL0 Register (for HT46R002) Bit 7 6 5 4 3 2 1 0 Name — — PWMSEL — PWMC — — — R/W — — R/W — R/W — — — POR — — 0 — 0 — — — Bit 7~6 Unimplemented, read as "0" Bit 5PWMSEL: PWM type selection 0: 6+2 1: 7+1 Bit 4 Unimplemented, read as "0" Bit 3PWMC: I/O or PWM selection 0: I/O or other pin-shared function 1: PWM Bit 2~0 Unimplemented, read as "0" CTRL0 Register (for HT46R003) Bit 7 6 5 4 3 2 1 0 Name — — PWMSEL — PWMC PFDC — — R/W — — R/W — R/W R/W — — POR — — 0 — 0 0 — — Bit 7~6 Unimplemented, read as "0" Bit 5PWMSEL: PWM type selection 0: 6+2 1: 7+1 Bit 4 Unimplemented, read as "0" Bit 3PWMC: I/O or PWM selection 0: PA0 1: PWM Bit 2PFDC: I/O or PFD selection 0: I/O or other pin-shared function 1: PFD Bit 1~0 Unimplemented, read as "0" CTRL1 Register Rev. 1.10 Bit 7 6 5 4 3 2 1 0 Name INTES1 INTES0 — — — — — — R/W R/W R/W — — — — — — POR 1 0 — — — — — — Bit 7, 6 INTES1, INTES0: External interrupt edge type selection 00: Disable 01: Rising edge trigger 10: Falling edge trigger 11: Dual edge trigger Bit 5~0 Unimplemented, read as "0" 21 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Oscillator Various oscillator options offer the user a wide range of functions according to their various application requirements. The flexible features of the oscillator functions ensure that the best optimization can be achieved in terms of speed and power saving. System Oscillator Overview In addition to being the source of the main system clock the oscillators also provide clock sources for the Watchdog Timer function, PWM and Timer/Event counter. Type Name Freq. Internal High Speed RC HIRC 8MHz Internal Low Speed RC LIRC 12kHz Oscillator Types System Clock Configurations There is one system oscillator implemented in these devices, internal 8MHz RC, HIRC. Also there is an internal 12kHz RC oscillator LIRC used as the clock source for the WDT function, PWM and Timer/Event counter. More details are described in the accompany sections. Internal RC Oscillator – HIRC The internal RC oscillator is a fully integrated system oscillator requiring no external components. The internal RC oscillator has the frequency of 8MHz .Device trimming during the manufacturing process and the inclusion of internal frequency compensation circuit is used to ensure that the influence of the power supply voltage, temperature and process variations on the oscillation frequency are minimized. Note that this internal system clock option requires no external pins for its operation. Refer to the A.C. Characteristics for more frequency accuracy details. Internal 12kHz Oscillator – LIRC The LIRC is a fully self-contained free running on-chip RC oscillator with a typical frequency of 12kHz at 5V, requiring no external components for its implementation. When the device enters the Sleep Mode, the system clock will stop running but the LIRC oscillator continues to free-run and to keep the watchdog active. However, to preserve power in certain applications the LIRC can be disabled by disabling the WDT function, PWM and Timer/Event counter. Timer/Event counter and PWM function in the halt mode. Rev. 1.10 22 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Power Down Mode and Wake-up Power Down Mode All of the Holtek microcontrollers have the ability to enter a Power Down Mode, also known as the HALT Mode or Sleep Mode. When the devices enter this mode, the normal operating current will be reduced to an extremely low standby current level. This occurs because when the devices enter the Power Down Mode, the system oscillator is stopped which reduces the power consumption to extremely low levels. However, as the devices maintain their present internal condition, they can be woken up at a later stage and continue running, without requiring a full reset. This feature is extremely important in application areas where the MCUs must have their power supply constantly maintained to keep the devices in a known condition. Entering the Power Down Mode There is only one way for the device to enter the Power Down Mode and that is to execute the “HALT” instruction in the application program. When this instruction is executed, the following will occur: • The system oscillator will stop running and the application program will stop at the “HALT” instruction. • The Data Memory contents and registers will maintain their present condition. • The WDT will be cleared and resume counting. • The I/O ports will maintain their present condition. In the status register, the Power Down flag, PDF, will be set and the Watchdog time-out flag, TO, will be cleared. Standby Current Considerations As the main reason for entering the Sleep Mode is to keep the current consumption of the MCU to as low a value as possible, perhaps only in the order of several micro-amps, there are other considerations which must also be taken into account by the circuit designer if the power consumption is to be minimized. Special attention must be made to the I/O pins on the device. All high-impedance input pins must be connected to either a fixed high or low level as any floating input pins could create internal oscillations and result in increased current consumption. Care must also be taken with the loads, which are connected to I/O pins, which are set as outputs. These should be placed in a condition in which minimum current is drawn or connected only to external circuits that do not draw current, such as other CMOS inputs. Rev. 1.10 23 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Wake-up After the system enters the Sleep Mode, it can be woken up from one of various sources listed as follows: • An external reset • An external falling edge on Port A • A system interrupt • A WDT overflow If the system is woken up by an external reset, the device will experience a full system reset, however, if the device is woken up by a WDT overflow, a Watchdog Timer reset will be initiated. Although both of these wake-up methods will initiate a reset operation, the actual source of the wake-up can be determined by examining the TO and PDF flags. The PDF flag is cleared by a system power-up or executing the clear Watchdog Timer instructions and is set when executing the “HALT” instruction. The TO flag is set if a WDT time-out occurs, and causes a wake-up that only resets the Program Counter and Stack Pointer, the other flags remain in their original status. Pins PA0~PA2, PA5 can be set via the PAWU register to permit a negative transition on the pin to wake-up the system. When a PA0~PA2, PA5 pin wake-up occurs, the program will resume execution at the instruction following the “HALT” instruction. If the system is woken up by an interrupt, then two possible situations may occur. The first is where the related interrupt is disabled or the interrupt is enabled but the stack is full, in which case the program will resume execution at the instruction following the “HALT” instruction. In this situation, the interrupt which woke-up the device will not be immediately serviced, but will rather be serviced later when the related interrupt is finally enabled or when a stack level becomes free. The other situation is where the related interrupt is enabled and the stack is not full, in which case the regular interrupt response takes place. If an interrupt request flag is set high before entering the SLEEP Mode, the wake-up function of the related interrupt will be ignored. No matter what the source of the wake-up event is, once a wake-up event occurs, there will be a time delay before normal program execution resumes. Consult the table for the related time Wake-up Source Oscillator Type HIRC, LIRC External RES tRSTD + tSST PA Port Interrupt tSST WDT Overflow Note: 1. tRSTD (reset delay time), tSYS (system clock) 2. tRSTD is power-on delay, typical time=50ms 3. tSST=16tSYS Wake-up Delay Time Rev. 1.10 24 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Watchdog Timer The Watchdog Timer, also known as the WDT, is provided to prevent program malfunctions or sequences from jumping to unknown locations, due to certain uncontrollable external events such as electrical noise. Watchdog Timer Clock Source The Watchdog Timer clock source is provided by the LIRC and the system clock fSYS which is sourced from the HIRC oscillator. The Watchdog Timer source clock is then subdivided by a ratio of 28 to 215 to give longer timeouts, the actual value being chosen using the WS2~WS0 bits in the WDTS register. The LIRC internal oscillator has an approximate period frequency of 12kHz at a supply voltage of 5V. However, it should be noted that this specified internal clock period can vary with VDD, temperature and process variations. Watchdog Timer Control Registers WDTS Register Bit 7 6 Name — — — R/W — — — POR — — — — Bit 7~3 5 4 3 2 1 0 — — WS2 WS1 WS0 — — R/W R/W R/W — 1 1 1 Unimplemented, read as “0” Bit 2~0WS2~WS0: WDT Time-out period selection 000: 28/fS 001: 29/fS 010: 210/fS 011: 211/fS 100: 212/fS 101: 213/fS 110: 214/fS 111: 215/fS These three bits determine the division ratio of the Watchdog Timer source clock, which in turn determines the timeout period. WDTC Register Bit Name 7 6 5 4 3 2 1 0 WDTCLS1 WDTCLS0 WDTEN5 WDTEN4 WDTEN3 WDTEN2 WDTEN1 WDTEN0 R/W R/W R/W R/W R/W R/W R/W R/W R/W POR 0 0 0 0 0 0 0 0 Bit 7~6WDTCLS1~WDTCLS0: WDT/Timer clock source 00: fLIRC 01: fSYS/4 10: fSYS 11: fSYS Bit 5~0WDTEN5~WDTEN0: WDT enable control 000000: Enable 101101: Disable Other values: MCU reset When these bits are changed by the environmental noise to reset the microcontroller, the reset operation will be activated after 2~3 LIRC clock cycles. Rev. 1.10 25 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Watchdog Timer Operation The Watchdog Timer operates by providing a device reset when its timer overflows. This means that in the application program and during normal operation the user has to strategically clear the Watchdog Timer before it overflows to prevent the Watchdog Timer from executing a reset. This is done using the clear watchdog instruction. Note that if the Watchdog Timer function is not enabled, then any instruction related to the Watchdog Timer will result in no operation. Setting the various Watchdog Timer options are controlled via the internal registers WDTC and WDTS. Enabling the Watchdog Timer can be controlled by the WDTEN bits in the internal WDTC register in the Data Memory. The Watchdog Timer will be disabled if bits WDTEN5~WDTEN0 in the WDTC register are written with the binary value 101101B while the WDT Timer will be enabled if these bits are written with the binary value 000000B. If these bits are written with the other values except 101101B and 000000B, the MCU will be reset. The Watchdog Timer clock can emanate from three different sources, selected by the WDTCLS1~WDTCLS0 bits in the WDTC register. These sources are fSYS, fSYS/4 or LIRC. It is important to note that when the system enters the Sleep Mode the instruction clock is stopped, therefore if it has selected fSYS or fSYS/4 as the Watchdog Timer clock source, the Watchdog Timer will stop. For systems that operate in noisy environments, it’s recommended to use the LIRC as the clock source. The division ratio of the prescaler is determined by bits 0, 1 and 2 of the WDTS register, known as WS0, WS1 and WS2. If the Watchdog Timer internal clock source is selected and with the WS0, WS1 and WS2 bits of the WDTS register all set high, the prescaler division ratio will be 1:32768, which will give a maximum time-out period. Under normal program operation, a Watchdog Timer time-out will initialize a device reset and set the status bit TO. However, if the system is in the Sleep Mode, when a Watchdog Timer time-out occurs, the device will be woken up, the TO bit in the status register will be set and only the Program Counter and Stack Pointer will be reset. Four methods can be adopted to clear the contents of the Watchdog Timer. The first is a WDT software reset, which means a certain value except 101101B and 000000B written into the WDTEN bit filed, the second is an external hardware reset, which means a low level on the external reset pin, the third is using the Clear Watchdog Timer software instructions and the fourth is via a “HALT” instruction. There is only one method of using software instruction to clear the Watchdog Timer. That is to use the “CLR WDT” instruction to clear the WDT. WDTEN bits Reset MCU RES pin reset “H�LT”Instr�ction “CLR WDT”Instr�ction fSYS fSYS/� LIRC M U X WDTCLS1� WDTCLS0 CLR fS 8-sta�e Prescaler fS/8 WDT Divider 8-to-1 MUX WS�~WS0 WDT Time-o�t (�8/fS ~ �15/fS) Watchdog Timer Rev. 1.10 26 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Reset and Initialization A reset function is a fundamental part of any microcontroller ensuring that the device can be set to some predetermined condition irrespective of outside parameters. The most important reset condition is after power is first applied to the microcontroller. In this case, internal circuitry will ensure that the microcontroller, after a short delay, will be in a well defined state and ready to execute the first program instruction. After this power-on reset, certain important internal registers will be set to defined states before the program commences. One of these registers is the Program Counter, which will be reset to zero forcing the microcontroller to begin program execution from the lowest Program Memory address. In addition to the power-on reset, situations may arise where it is necessary to forcefully apply a reset condition when the microcontroller is running. One example of this is where after power has been applied and the microcontroller is already running, the RES line is forcefully pulled low. In such a case, known as a normal operation reset, some of the microcontroller registers remain unchanged allowing the microcontroller to deal with normal operation after the reset line is allowed to return high. Another type of reset is when the Watchdog Timer overflows and resets the microcontroller. All types of reset operations result in different register conditions being set. Another reset exists in the form of a Low Voltage Reset, LVR, where a full reset, similar to the RES reset is implemented in situations where the power supply voltage falls below a certain threshold. Reset Functions There are five ways in which a microcontroller reset can occur, through events occurring both internally and externally: Power-on Reset The most fundamental and unavoidable reset is the one that occurs after power is first applied to the microcontroller. As well as ensuring that the Program Memory begins execution from the first memory address, a power-on reset also ensures that certain other registers are preset to known conditions. All the I/O port and port control registers will power up in a high condition ensuring that all pins will be first set to inputs. Although the microcontroller has an internal RC reset function, if the VDD power supply rise time is not fast enough or does not stabilize quickly at power-on, the internal reset function may be incapable of providing proper reset operation. For this reason it is recommended that an external RC network is connected to the RES pin, whose additional time delay will ensure that the RES pin remains low for an extended period to allow the power supply to stabilize. During this time delay, normal operation of the microcontroller will be inhibited. After the RES line reaches a certain voltage value, the reset delay time tRSTD is invoked to provide an extra delay time after which the microcontroller will begin normal operation. The abbreviation SST in the figures stands for System Start-up Timer. For most applications a resistor connected between VDD and the RES pin and a capacitor connected between VSS and the RES pin will provide a suitable external reset circuit. Any wiring connected to the RES pin should be kept as short as possible to minimize any stray noise interference. Note: TRSTD is power-on delay, typical time=50ms Power-On Reset Timing Chart Rev. 1.10 27 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU For applications that operate within an environment where more noise is present the reset circuit shown is recommended. Note: “*” It is recommended that this component is added for added ESD protection. “**” It is recommended that this component is added in environments where power line noise is significant. External RES Circuit More information regarding external reset circuits is located in Application Note HA0075E on the Holtek website. RES Pin Reset This type of reset occurs when the microcontroller is already running and the RES pin is forcefully pulled low by software control using the register EXTRESB. In this case of other reset, the Program Counter will reset to zero and program execution initiated from this point. Note: TRSTD is power-on delay, typical time=50ms RES Reset Timing Chart • EXTRESB Register Bit 7 6 5 Name — — — R/W — — — R/W R/W R/W R/W R/W POR — — — 0 0 0 0 0 Bit 7~5 4 3 2 1 0 RESBEN4 RESBEN3 RESBEN2 RESBEN1 RESBEN0 Described in other section. Bit 4~0RESBEN4~RESBEN0: External Reset Pin select 00000: I/O Pin 10101: External Reset Pin Other: MCU reset When these bits are changed by the environmental noise to reset the microcontroller, the reset operation will be activated after 2~3 LIRC clock cycles. Rev. 1.10 28 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Low Voltage Reset – LVR The microcontroller contains an always enabled low voltage reset circuit in order to monitor the supply voltage of the device. This voltage is fixed at 2.1V (VLVR). If the supply voltage of the device drops to within a range of 0.9V~VLVR such as might occur when changing a battery, the LVR will automatically reset the device internally. The LVR includes the following specifications: For a valid LVR signal, a low voltage, i.e., a voltage in the range between 0.9V~VLVR must exist for greater than the value tLVR specified in the A.C. characteristics. If the low voltage state does not exceed tLVR, the LVR will ignore it and will not perform a reset function. Note that the LVR function will automatically be disabled when the MCU enters the Power Down Mode. Note: TRSTD is power-on delay, typical time=50ms Low Voltage Reset Timing Chart Watchdog Time-out Reset during Normal Operation The Watchdog time-out Reset during normal operation is the same as a hardware RES pin reset except that the Watchdog time-out flag TO will be set to “1”. Note: TRSTD is power-on delay, typical time=50ms WDT Time-out Reset during Normal Operation Timing Chart Watchdog Time-out Reset during Sleep Mode The Watchdog time-out Reset during Sleep Mode is a little different from other kinds of reset. Most of the conditions remain unchanged except that the Program Counter and the Stack Pointer will be cleared to “0” and the TO flag will be set to “1”. Refer to the A.C. Characteristics for tSST details. Note: TSST is 16 clock cycles for the system clock source is provided by HIRC. WDT Time-out Reset during Sleep Timing Chart Rev. 1.10 29 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Reset Initial Conditions The different types of reset described affect the reset flags in different ways. These flags, known as PDF and TO are located in the status register and are controlled by various microcontroller operations, such as the Sleep Mode function or Watchdog Timer. The reset flags are shown in the table: TO PDF 0 0 Power-on reset RESET Conditions u u RES or LVR reset during NORMAL Mode operation 1 u WDT time-out reset during NORMAL Mode operation 1 1 WDT time-out reset during Sleep Mode operation Note: “u” stands for unchanged The following table indicates the way in which the various components of the microcontroller are affected after a power-on reset occurs. Item Condition After RESET Program Counter Reset to zero Interrupts All interrupts will be disabled WDT Clear after reset, WDT begins counting Timer/Event Counter Timer Counter will be turned off Precaler The Timer Counter Prescaler will be cleared Input/Output Ports I/O ports will be set as inputs Stack Pointer Stack Pointer will point to the top of the stack The different kinds of resets all affect the internal registers of the microcontroller in different ways. To ensure reliable continuation of normal program execution after a reset occurs, it is important to know what condition the microcontroller is in after a particular reset occurs. The following table describes how each type of reset affects the microcontroller internal registers. Rev. 1.10 30 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU HT46R002 Power-on Reset RES Reset (Normal operation) RES Reset (HALT) WDT Time-out (Normal Operation) WDT Time-out (HALT)* PCL 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 MP0 1xxx xxxx 1 uuu uuuu 1 uuu uuuu 1 uuu uuuu 1 uuu uuuu MP1 1xxx xxxx 1 uuu uuuu 1 uuu uuuu 1 uuu uuuu 1 uuu uuuu ACC xxxx xxxx uuuu uuuu uuuu uuuu uuuu uuuu uuuu uuuu TBLP xxxx xxxx uuuu uuuu uuuu uuuu uuuu uuuu uuuu uuuu TBLH --xx xxxx - - uu uuuu - - uu uuuu - - uu uuuu - - uu uuuu WDTS - - - - - 111 - - - - - 111 - - - - - 111 - - - - - 111 - - - - - uuu STATUS --00 xxxx - - uu uuuu - - 0 1 uuuu - - 1 u uuuu - - 1 1 uuuu INTC0 -000 0000 -000 0000 -000 0000 -000 0000 - uuu uuuu TMR0 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx uuuu uuuu TMR0C 00-0 1000 00-0 1000 00-0 1000 00-0 1000 uu - u uuuu PA 1111 1111 1111 1111 1111 1111 1111 1111 uuuu uuuu PAWU --0- -000 --0- -000 --0- -000 --0- -000 - - u - - uuu PAPU -000 0000 -000 0000 -000 0000 -000 0000 - uuu uuuu CTRL0 --0- 0--- --0- 0--- --0- 0--- --0- 0--- --u- u--- CTRL1 10-- ---- 10-- ---- 10-- ---- 10-- ---- uu - - - - - - WDTC 0000 0000 0000 0000 0000 0000 0000 0000 uuuu uuuu PWM0 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx uuuu uuuu ADRL xxxx ---- xxxx ---- xxxx ---- xxxx ---- uuuu - - - - ADRH xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx uuuu uuuu ADCR 0100 0000 0100 0000 0100 0000 0100 0000 uuuu uuuu ACSR 10-- -000 10-- -000 10-- -000 10-- -000 1 u - - - uuu EXTRESB ---0 0000 ---0 0000 ---0 0000 ---0 0000 - - - u uuuu Register Note: “*” means “warm reset” “-” not implement “u” means “unchanged” “x” means “unknown” Rev. 1.10 31 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU HT46R003 Power-on Reset RES Reset (Normal operation) RES Reset (HALT) WDT Time-out (Normal Operation) WDT Time-out (HALT)* PCL 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 MP0 1xxx xxxx 1 uuu uuuu 1 uuu uuuu 1 uuu uuuu 1 uuu uuuu MP1 1xxx xxxx 1 uuu uuuu 1 uuu uuuu 1 uuu uuuu 1 uuu uuuu ACC xxxx xxxx uuuu uuuu uuuu uuuu uuuu uuuu uuuu uuuu TBLP xxxx xxxx uuuu uuuu uuuu uuuu uuuu uuuu uuuu uuuu TBLH --xx xxxx - - uu uuuu - - uu uuuu - - uu uuuu - - uu uuuu WDTS - - - - - 111 - - - - - 111 - - - - - 111 - - - - - 111 - - - - - uuu STATUS --00 xxxx - - uu uuuu - - 0 1 uuuu - - 1 u uuuu - - 1 1 uuuu INTC0 -000 0000 -000 0000 -000 0000 -000 0000 - uuu uuuu TMR0 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx uuuu uuuu TMR0C 00-0 1000 00-0 1000 00-0 1000 00-0 1000 uu - u uuuu PA 1111 1111 1111 1111 1111 1111 1111 1111 uuuu uuuu PAC 1111 1111 1111 1111 1111 1111 1111 1111 uuuu uuuu PAWU --0- -000 --0- -000 --0- -000 --0- -000 - - u - - uuu PAPU -000 0000 -000 0000 -000 0000 -000 0000 - uuu uuuu PC - - 11 1111 - - 11 1111 - - 11 1111 - - 11 1111 - - uu uuuu PCC - - 11 1111 - - 11 1111 - - 11 1111 - - 11 1111 - - uu uuuu PCPU --00 0000 --00 0000 --00 0000 --00 0000 - - uu uuuu CTRL0 --0- 00-- --0- 00-- --0- 00-- --0- 00-- --u- uu-- CTRL1 10-- ---- 10-- ---- 10-- ---- 10-- ---- uu - - - - - - WDTC 0000 0000 0000 0000 0000 0000 0000 0000 uuuu uuuu PWM0 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx uuuu uuuu ADRL xxxx ---- xxxx ---- xxxx ---- xxxx ---- uuuu - - - - ADRH xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx uuuu uuuu ADCR 0100 0000 0100 0000 0100 0000 0100 0000 uuuu uuuu ACSR 10-- -000 10-- -000 10-- -000 10-- -000 1 u - - - uuu EXTRESB ---0 0000 ---0 0000 ---0 0000 ---0 0000 - - - u uuuu Register Note: “*” means “warm reset” “-” not implement “u” means “unchanged” “x” means “unknown” Rev. 1.10 32 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Input/Output Ports Holtek microcontrollers offer considerable flexibility on their I/O ports. Most pins can have either an input or output designation under user program control. Additionally, as there are pull-high resistors and wake-up software configurations, the user is provided with an I/O structure to meet the needs of a wide range of application possibilities. The devices provide bidirectional input/output lines labeled with port names PA and PC. These I/O ports are mapped to the RAM Data Memory with specific addresses as shown in the Special Purpose Data Memory table. All of these I/O ports can be used for input and output operations. For input operation, these ports are non-latching, which means the inputs must be ready at the T2 rising edge of instruction “MOV A, [m]”, where m denotes the port address. For output operation, all the data is latched and remains unchanged until the output latch is rewritten. I/O Registers List • HT46R002 Bit Register Name 7 6 5 4 3 2 1 0 PA PA7 PA6 PA5 PA4 PA3 PA2 PA1 PA0 PAC PAC7 PAC6 PAC5 PAC4 PAC3 PAC2 PAC1 PAC0 PAPU — PAPU6 PAPU5 PAPU4 PAPU3 PAPU2 PAPU1 PAPU0 PAWU — — PAWU5 — — PAWU2 PAWU1 PAWU0 7 6 5 4 3 2 1 0 • HT46R003 Bit Register Name PA PA7 PA6 PA5 PA4 PA3 PA2 PA1 PA0 PAC PAC7 PAC6 PAC5 PAC4 PAC3 PAC2 PAC1 PAC0 PAPU — PAPU6 PAPU5 PAPU4 PAPU3 PAPU2 PAPU1 PAPU0 PAWU — — PAWU5 — — PAWU2 PAWU1 PAWU0 PC — — PC5 PC4 PC3 PC2 PC1 PC0 PCC — — PCC5 PCC4 PCC3 PCC2 PCC1 PCC0 PCPU — — PCPU5 PCPU4 PCPU3 PCPU2 PCPU1 PCPU0 Pull-high Resistors Many product applications require pull-high resistors for their switch inputs usually requiring the use of an external resistor. To eliminate the need for these external resistors, all I/O pins, when configured as an input have the capability of being connected to an internal pull-high resistor. These pull-high resistors are selected using a registers PAPU and PCPU located in the Data Memory. The pull-high resistors are implemented using weak PMOS transistors. Note that pin PA7 does not have a pull-high resistor selection. Rev. 1.10 33 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU PAPU Register Bit 7 6 5 4 3 2 1 0 Name — PAPU6 PAPU5 PAPU4 PAPU3 PAPU2 PAPU1 PAPU0 R/W — R/W R/W R/W R/W R/W R/W R/W POR — 0 0 0 0 0 0 0 Bit 7 Unimplemented, read as "0" Bit 6~0 PAPU6~PAPU0: Port A bit6~bit0 pull-high control 0: Disable 1: Enable PCPU Register – HT46R003 only Bit 7 6 5 4 3 2 1 0 Name — — PCPU5 PCPU4 PCPU3 PCPU2 PCPU1 PCPU0 R/W — — R/W R/W R/W R/W R/W R/W POR — — 0 0 0 0 0 0 Bit 7, 6 Unimplemented, read as "0" Bit 5~0PCPU5~PCPU0: Port C bit5~bit0 pull-high control 0: Disable 1: Enable Port A Wake-up If the HALT instruction is executed, the device will enter the Sleep Mode, where the system clock will stop resulting in power being conserved, a feature that is important for battery and other low-power applications. Various methods exist to wake-up the microcontroller, one of which is to change the logic condition on one of the PA0~PA2, PA5pins from high to low. After a HALT instruction forces the microcontroller into entering the Sleep Mode, the processor will remain in a low-power state until the logic condition of the selected wake-up pin on Port A changes from high to low. This function is especially suitable for applications that can be woken up via external switches. Note that pins PA0~PA2, PA5 can be selected individually to have this wake-up feature using an internal register known as PAWU, located in the Data Memory. PAWU Register Bit 7 6 5 4 3 2 1 0 Name — — PAWU5 — — PAWU2 PAWU1 PAWU0 R/W — — R/W — — R/W R/W R/W POR — — 0 — — 0 0 0 Bit 7~6 Unimplemented, read as "0" Bit 5PAWU5: Port A bit 5 wake-up control 0: Disable 1: Enable Bit 4~3 Unimplemented, read as "0" Bit 2~0PAWU2~PAWU0: Port A bit 2~bit 0 wake-up control 0: Disable 1: Enable Rev. 1.10 34 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU I/O Port Control Registers Each port has its own control register known as PAC, PCC, which control the input/output configuration. With this control register, each I/O pin with or without pull-high resistors can be reconfigured dynamically under software control. For the I/O pin to function as an input, the corresponding bit of the control register must be written as a “1”. This will then allow the logic state of the input pin to be directly read by instructions. When the corresponding bit of the control register is written as a “0”, the I/O pin will be set as a CMOS output. If the pin is currently set as an output, instructions can still be used to read the output register. However, it should be noted that the program will in fact only read the status of the output data latch and not the actual logic status of the output pin. PAC Register Bit 7 6 5 4 3 2 1 0 Name PAC7 PAC6 PAC5 PAC4 PAC3 PAC2 PAC1 PAC0 R/W R/W R/W R/W R/W R/W R/W R/W R/W POR 1 1 1 1 1 1 1 1 Bit 7~0 Port A bit 7~bit 0 Input/Output control 0: Output 1: Input PCC Register – HT46R003 only Rev. 1.10 Bit 7 6 5 4 3 2 1 0 Name — — PCC5 PCC4 PCC3 PCC2 PCC1 PCC0 R/W — — R/W R/W R/W R/W R/W R/W POR — — 1 1 1 1 1 1 Bit 7~6 Unimplemented, read as "0" Bit 5~0 Port C bit 5~bit 0 Input/Output control 0: Output 1: Input 35 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Pin-shared Functions The flexibility of the microcontroller range is greatly enhanced by the use of pins that have more than one function. Limited numbers of pins can force serious design constraints on designers but by supplying pins with multi-functions, many of these difficulties can be overcome. For some pins, the chosen function of the multi-function I/O pins is set by application program control. External Interrupt Input The external interrupt pin, INT, is pin-shared with an I/O pin. To use the pin as an external interrupt input the correct bits in the INTC0 register must be programmed. The pin must also be set as an input by setting the PAC2 bit in the Port Control Register. A pull-high resistor can also be selected via the appropriate port pull-high resistor register. Note that even if the pin is set as an external interrupt input the I/O function still remains. External Timer/Event Counter Input The Timer/Event Counter pin TMR is pin-shared with I/O pins For this shared pin to be used as Timer/Event Counter input, the Timer/Event Counter must be configured to be in the Event Counter or Pulse Width Capture Mode. This is achieved by setting the appropriate bits in the Timer/Event Counter Control Register. The pin must also be set as input by setting the appropriate bit in the Port Control Register. Pull-high resistor options can also be selected using the port pull-high resistor registers. Note that even if the pin is set as an external timer input the I/O function still remains. PFD Output (for HT46R003) The PFD function output is pin-shared with an I/O pin. The output function of this pin is chosen using the CTRL0 register. Note that the corresponding bit of the port control register must be set the pin as an output to enable the PFD output. If the port control register has set the pin as an input, then the pin will function as a normal logic input with the usual pull-high selection, even if the PFD function has been selected. PWM Output For the devices the PWM function is included. The PWM function whose outputs are pin-shared with I/O pins. The PWM output functions are chosen using the CTRL0 register. Note that the corresponding bit of the port control registers, for the output pin, must setup the pin as an output to enable the PWM output. If the pins are setup as inputs, then the pin will function as a normal logic input with the usual pull-high selections, even if the PWM registers have enabled the PWM function. A/D Iutput The devices have four inputs to the A/D converter. All of these analog inputs are pin-shared with I/O pins. If these pins are to be used as A/D inputs and not as I/O pins, then the corresponding PCRn bits in the A/D converter control register, ADCR, must be properly setup. If chosen as I/O pins, then full pull-high resistor control remains, however if used as A/D inputs then any pull-high resistor control associated with these pins will be automatically disconnected. Rev. 1.10 36 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU I/O Pin Structures The accompanying diagrams illustrate the I/O pin internal structures. As the exact logical construction of the I/O pin may differ from these drawings, they are supplied as a guide only to assist with the functional understanding of the I/O pins. Generic Input/Output Ports PA7 NMOS Input/Output Port Rev. 1.10 37 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU A/D Input/Output Port Programming Considerations Within the user program, one of the things first to consider is port initialization. After a reset, all of the I/O data and port control registers will be set to high. This means that all I/O pins will be defaulted to an input state, the level of which depends on the other connected circuitry and whether pull-high selections have been chosen. If the port control registers are then programmed to set some pins as outputs, these output pins will have an initial high output value unless the associated port data registers are first programmed. Selecting which pins are inputs and which are outputs can be achieved byte-wide by loading the correct values into the appropriate port control register or by programming individual bits in the port control register using the “SET [m].i” and “CLR [m].i” instructions. Note that when using these bit control instructions, a read-modify-write operation takes place. The microcontroller must first read in the data on the entire port, modify it to the required new bit values and then rewrite this data back to the output ports. Read Modify Write Timing Pins PA0~PA2, PA5 each have wake-up functions, selected via the PAWU register. When the device is in the Sleep Mode, various methods are available to wake the device up. One of these is a high to low transition of any pins. Single or multiple pins on Port A can be set to have this function. Rev. 1.10 38 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Timer/Event Counter The provision of timer form an important part of any microcontroller, giving the designer a means of carrying out time related functions. The devices contain from an 8-bit count-up timer. As the timer has three different operating modes, they can be configured to operate as a general timer, an external event counter or as a pulse width capture device. The provision of an internal prescaler to the clock circuitry on gives added range to the timer. There are two types of registers related to the Timer/Event Counter 0. The first is the register that contains the actual value of the timer and into which an initial value can be preloaded. Reading from this register retrieves the contents of the Timer/Event Counter 0. The second type of associated register is the Timer Control Register which defines the timer options and determines how the timer is to be used. The device can have the timer clock configured to come from the internal clock source. In addition, the timer clock source can also be configured to come from an external timer pin. Configuring the Timer/Event Counter Input Clock Source The Timer/Event Counter clock source can originate from various sources, an internal clock or an external pin. The internal clock source is used when the timer is in the timer mode. For the Timer/ Event Counter 0, tQI HQI his internal clock source is first divided by a prescaler, the division ratio of which is conditioned by the Timer Control Register bits T0PSC2~T0PSC0. The internal clock source can be derived from the system clock fSYS or from the instruction clock fSYS/4 or the internal low speed oscillator LIRC for Timer/Event Counter selected by the clock selection bits WDTCLS1~WDTCLS0 in the WDTC register. An external clock source is used when the Timer/Event Counter is in the event counting mode, the clock source being provided on an external timer pin TMR. Depending upon the condition of the T0EG bit, each high to low, or low to high transition on the external timer pin will increment the counter by one. PWM PWM Circ�itry fSYS M f S U X fSYS/� LIRC WDTCLS1� WDTCLS0 8-to-1 MUX 7 8-sta�e Prescaler 8-to-1 MUX fS/�8 WS�~WS0 WDT Divider WDT Time-o�t (�8/fS ~ �15/fS) To Timer 0 internal clock T0PSC�~T0PSC0 Clock Source for Timer/PWM/WDT Note: “*” means for HT46R003 only. 8-bit Timer/Event Counter 0 Structure Rev. 1.10 39 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Timer Register – TMR0 The timer register is special function register located in the Special Purpose Data Memory and is the place where the actual timer value is stored. The register is known as TMR0. The value in the timer register increases by one each time an internal clock pulse is received or an external transition occurs on the external timer pin. The timer will count from the initial value loaded by the preload register to the full count of FFH at which point the timer overflows and an internal interrupt signal is generated. The timer value will then reset with the initial preload register value and continue counting. Note that to achieve a maximum full range count of FFH, the preload register must first be cleared. It should be noted that after power-on, the preload register will be in an unknown condition. Note that if the Timer/Event Counter is in an OFF condition and data is written to its preload register, this data will be immediately written into the actual counter. However, if the counter is enabled and counting, any new data written into the preload data register during this period will remain in the preload register and will only be written into the actual counter the next time an overflow occurs. Timer Control Register – TMR0C The flexible features of the Holtek microcontroller Timer/Event Counter enable it to operate in three different modes, the options of which are determined by the contents of their respective control register. The Timer Control Register is known as TMR0C. It is the Timer Control Register together with its corresponding timer register that controls the full operation of the Timer/Event Counter. Before the timer can be used, it is essential that the Timer Control Register is fully programmed with the right data to ensure its correct operation, a process that is normally carried out during program initialization. To select which of the three modes the timer is to operate in, either in the timer mode, the event counting mode or the pulse width capture mode, bits 7 and 6 of the Timer Control Register, which are known as the bit pair T0M1/T0M0, must be set to the required logic levels. The timer-on bit, which is bit 4 of the Timer Control Register and known as T0ON, provides the basic on/off control of the respective timer. Setting the bit to high allows the counter to run. Clearing the bit stops the counter. Bits 0~2 of the Timer Control Register determine the division ratio of the input clock prescaler. The prescaler bit settings have no effect if an external clock source is used. If the timer is in the event count or pulse width capture mode, the active transition edge level type is selected by the logic level of bit 3 of the Timer Control Register which is known as T0EG. Rev. 1.10 40 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU TMR0C Register Bit 7 6 5 4 3 2 1 0 Name T0M1 T0M0 — T0ON T0EG T0PSC2 T0PSC1 T0PSC0 R/W R/W R/W — R/W R/W R/W R/W R/W POR 0 0 — 0 1 0 0 0 Bit 7~6T0M1~T0M0: Timer operation mode selection 00: No mode available 01: Event counter mode 10: Timer mode 11: Pulse width capture mode Bit 5 Unimplemented, read as "0" Bit 4T0ON: Timer/event counter counting enable 0: Disable 1: Enable Bit 3T0EG: Timer/Event Counter active edge selection In event counter mode (T0M1~T0M0=01) 0: Count on rising edge 1: Count on falling edge In pulse width measurement mode (T0M1~T0M0=11) 0: Start counting on falling edge, stop on the rising edge 1: Start counting on rising edge, stop on the falling edge Bit 2~0T0PSC2~T0PSC0: Timer prescalar rate selection 000: fS 001: fS/2 010: fS/4 011: fS/8 100: fS/16 101: fS/32 110: fS/64 111: fS/128 Timer Mode In this mode, the Timer/Event Counter can be utilized to measure fixed time intervals, providing an internal interrupt signal each time the Timer/Event Counter overflows. To operate in this mode, the Operating Mode Select bit pair, T0M1/T0M0, in the Timer Control Register must be set to the correct value as shown. Bit7 Bit6 1 0 Control Register Operating Mode Select Bits for the Timer Mode In this mode the internal clock is used as the timer clock. The timer input clock source is fSYS, fSYS/4 or fLIRC. However, this timer clock source is further divided by a prescaler, the value of which is determined by the bits T0PSC2~T0PSC0 in the Timer Control Register. The timer-on bit, T0ON must be set high to enable the timer to run. Each time an internal clock high to low transition occurs, the timer increments by one. When the timer is full and overflows, an interrupt signal is generated and the timer will reload the value already loaded into the preload register and continue counting. A timer overflow condition and corresponding internal interrupts are two of the wake-up sources. However, the internal interrupts can be disabled by ensuring that the T0E bits of the INTC0 register are reset to zero. Rev. 1.10 41 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Timer Mode Timing Chart Event Counter Mode In this mode, a number of externally changing logic events, occurring on the external timer TMR pin, can be recorded by the Timer/Event Counter. To operate in this mode, the Operating Mode Select bit pair, T0M1/T0M0, in the Timer Control Register must be set to the correct value as shown. Bit7 Bit6 0 1 Control Register Operating Mode Select Bits for the Timer Mode In this mode, the external timer TMR pin, is used as the Timer/Event Counter clock source, however it is not divided by the internal prescaler. After the other bits in the Timer Control Register have been set, the enable bit T0ON, which is bit 4 of the Timer Control Register, can be set high to enable the Timer/Event Counter to run. If the Active Edge Select bit, T0EG, which is bit 3 of the Timer Control Register, is low, the Timer/Event Counter will increment each time the external timer pin receives a low to high transition. If the T0EG is high, the counter will increment each time the external timer pin receives a high to low transition. When it is full and overflows, an interrupt signal is generated and the Timer/Event Counter will reload the value already loaded into the preload register and continue counting. The interrupt can be disabled by ensuring that the Timer/Event Counter Interrupt Enable bit in the corresponding Interrupt Control Register. It is reset to zero. As the external timer pin is shared with an I/O pin, to ensure that the pin is configured to operate as an event counter input pin, two things have to happen. The first is to ensure that the Operating Mode Select bits in the Timer Control Register place the Timer/Event Counter in the Event Counting Mode. The second is to ensure that the port control register configures the pin as an input. It should be noted that in the event counting mode, even if the microcontroller is in the Sleep Mode, the Timer/Event Counter will continue to record externally changing logic events on the timer input TMR pin. As a result when the timer overflows it will generate a timer interrupt and corresponding wake-up source. Event Counter Mode Timing Chart (T0EG=1) Rev. 1.10 42 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Pulse Width Capture Mode In this mode, the Timer/Event Counter can be utilised to measure the width of external pulses applied to the external timer pin. To operate in this mode, the Operating Mode Select bit pair, T0M1/ T0M0, in the Timer Control Register must be set to the correct value as shown. Bit7 Bit6 1 1 Control Register Operating Mode Select Bits for the Pulse Width Capture Mode In this mode the internal clock, fSYS, fSYS/4 or fLIRC is used as the internal clock for the 8-bit Timer/ Event Counter. However, the clock source, fSYS, for the 8-bit timer is further divided by a prescaler, the value of which is determined by the Prescaler Rate Select bits T0PSC2~T0PSC0, which are bit 2~0 of the Timer Control Register, After other bits in the Timer Control Register have been set, the enable bit T0ON, which is bit 4 of the Timer Control Register, can be set high to enable the Timer/ Event Counter, however it will not actually start counting until an active edge is received on the external timer pin. If the Active Edge Select bit T0EG which is bit 3 of the Timer Control Register is low, once a high to low transition has been received on the external timer pin, the Timer/Event Counter will start counting until the external timer pin returns to its original high level. At this point the enable bit will be automatically reset to zero and the Timer/Event Counter will stop counting. If the Active Edge Select bit is high, the Timer/Event Counter will begin counting once a low to high transition has been received on the external timer pin and stop counting when the external timer pin returns to its original low level. As before, the enable bit will be automatically reset to zero and the Timer/Event Counter will stop counting. It is important to note that in the pulse width capture mode, the enable bit is automatically reset to zero when the external control signal on the external timer pin returns to its original level, whereas in the other two modes the enable bit can only be reset to zero under program control. The residual value in the Timer/Event Counter, which can now be read by the program, therefore represents the length of the pulse received on the TMR pin. As the enable bit has now been reset, any further transitions on the external timer pin will be ignored. The timer cannot begin further pulse width capture until the enable bit is set high again by the program. In this way, single shot pulse measurements can be easily made. It should be noted that in this mode the Timer/Event Counter is controlled by logical transitions on the external timer pin and not by the logic level. When the Timer/ Event Counter is full and overflows, an interrupt signal is generated and the Timer/Event Counter will reload the value already loaded into the preload register and continue counting. The interrupt can be disabled by ensuring that the Timer/Event Counter Interrupt Enable bit in the corresponding Interrupt Control Register, it is reset to zero. As the TMR pin is shared with an I/O pin, to ensure that the pin is configured to operate as a pulse width capture pin, two things have to be implemented. The first is to ensure that the Operating Mode Select bits in the Timer Control Register place the Timer/Event Counter in the pulse width capture mode, the second is to ensure that the port control register configure the pin as an input. Rev. 1.10 43 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Pulse Width Capture Mode Timing Chart (T0EG=0) Prescaler Bits T0PSC2~T0PSC0 of the TMR0C register can be used to define a division ratio for the internal clock source of the Timer/Event Counter enabling longer time out periods to be set. PFD Function (for HT46R003) The Programmable Frequency Divider provides a means of producing a variable frequency output suitable for application, such as some interfaces requiring a precise frequency generator. The Timer/Event Counter overflow signal is the clock source for the PFD function, which is controlled by PFDC bit in CTRL0. For this device the clock source can come from Timer/Event Counter 0. The output frequency is controlled by loading the required values into the timer prescaler and timer registers to give the required division ratio. The counter will begin to count-up from this preload register value until full, at which point an overflow signal is generated, causing both the PFD outputs to change state. Then the counter will be automatically reloaded with the preload register value and continue counting-up. If the CTRL0 register has selected the PFD function, then for PFD output to operate, it is essential for the Port A control register PAC to set the PFD pins as outputs. PA6 must be set high to activate the PFD. The output data bits can be used as the on/off control bit for the PFD outputs. Note that the PFD outputs will all be low if the output data bit is cleared to zero. PFD Function I/O Interfacing The Timer/Event Counter, when configured to run in the event counter or pulse width capture mode, requires the use of an external timer pin for its operation. As this pin is a shared pin it must be configured correctly to ensure that it is set for use as a Timer/Event Counter input pin. This is achieved by ensuring that the mode selects bits in the Timer/Event Counter control register, either the event counter or pulse width capture mode. Additionally the corresponding Port Control Register bit must be set high to ensure that the pin is set as an input. Any pull-high resistor connected to this pin will remain valid even if the pin is used as a Timer/Event Counter input. Rev. 1.10 44 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Programming Considerations When running in the timer mode, the internal system clock is used as the timer clock source and is therefore synchronised with the overall operation of the microcontroller. In this mode when the appropriate timer register is full, the microcontroller will generate an internal interrupt signal directing the program flow to the respective internal interrupt vector. For the pulse width capture mode, the internal system clock is also used as the timer clock source but the timer will only run when the correct logic condition appears on the external timer input pin. As this is an external event and not synchronised with the internal timer clock, the microcontroller will only see this external event when the next timer clock pulse arrives. As a result, there may be small differences in measured values requiring programmers to take this into account during programming. The same applies if the timer is configured to be in the event counting mode, which again is an external event and not synchronised with the internal system or timer clock. When the Timer/Event Counter is read, or if data is written to the preload register, the clock is inhibited to avoid errors, however as this may result in a counting error, this should be taken into account by the programmer. Care must be taken to ensure that the timers are properly initialised before using them for the first time. The associated timer enable bits in the interrupt control register must be properly set otherwise the internal interrupt associated with the timer will remain inactive. The edge select, timer mode and clock source control bits in timer control register must also be correctly set to ensure the timer is properly configured for the required application. It is also important to ensure that an initial value is first loaded into the timer registers before the timer is switched on; this is because after power-on the initial values of the timer registers are unknown. After the timer has been initialised the timer can be turned on and off by controlling the enable bit in the timer control register. When the Timer/Event Counter overflows, its corresponding interrupt request flag in the interrupt control register will be set. If the Timer/Event Counter interrupt is enabled this will in turn generate an interrupt signal. However irrespective of whether the interrupts are enabled or not, a Timer/Event Counter overflow will also generate a wake-up signal if the device is in a Power-down condition. This situation may occur if the Timer/Event Counter is in the Event Counting Mode and if the external signal continues to change state. In such a case, the Timer/Event Counter will continue to count these external events and if an overflow occurs the device will be woken up from its Powerdown condition. To prevent such a wake-up from occurring, the timer interrupt request flag should first be set high before issuing the “HALT” instruction to enter the Sleep Mode. Rev. 1.10 45 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Timer Program Example The program shows how the Timer/Event Counter registers are set along with how the interrupts are enabled and managed. Note how the Timer/Event Counter is turned on, by setting bit 4 of the Timer Control Register. The Timer/Event Counter can be turned off in a similar way by clearing the same bit. This example program sets the Timer/Event Counters to be in the timer mode, which uses the internal system clock as their clock source. PFD Programming Example org 04h ; org 08h ; jmp tmr0int ; : : org 20h ; : : ; tmr0int: : ; : : begin: ; mov a,09bh ; mov tmr0,a mov a,081h ; mov tmr0c,a ; mov a,0c0H ; mov wdtc,a mov a,05h ; mov intc0,a : : set tmr0c.4 ; : : Rev. 1.10 external interrupt vector Timer Counter 0 interrupt vector jump here when Timer 0 overflows main program internal Timer 0 interrupt routine Timer 0 main program placed here set Timer 0 registers set Timer 0 preload value set Timer 0 control register timer mode and prescaler set to/2 set interrupt register select fSYS for the TMR0 clock source enable master interrupt and both timer interrupts start Timer 0 46 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Pulse Width Modulator The devices include one 8-bit PWM function. Useful for the applications such as motor speed control, the PWM function provides outputs with a fixed frequency but with a duty cycle that can be varied by setting particular values into the corresponding PWM register. PWM Operation The register, known as PWM and located in the Data Memory is assigned to each Pulse Width Modulator channel. It is here that the 8-bit value, which represents the overall duty cycle of one modulation cycle of the output waveform, should be placed. To increase the PWM modulation frequency, each modulation cycle is subdivided into two or four individual modulation subsections, known as the 7+1 mode or 6+2 mode respectively. The required mode and the on/off control for each PWM channel is selected using the CTRL0 register. Note that when using the PWM, it is only necessary to write the required value into the PWM register and select the required mode set and on/ off control using the CTRL0 register, the subdivision of the waveform into its sub-modulation cycles is implemented automatically within the microcontroller hardware. The PWM clock source fS comes from the system clock fSYS, fSYS/4 or fLIRC This method of dividing the original modulation cycle into a further 2 or 4 sub-cycles enable the generation of higher PWM frequencies which allow a wider range of applications to be served. The difference between what is known as the PWM cycle frequency and the PWM modulation frequency should be understood. As the PWM value is 8-bits wide, the overall PWM cycle frequency is fS/256. However, when in the 7+1 mode of operation the PWM modulation frequency will be fS/128, while the PWM modulation frequency for the 6+2 mode of operation will be fS/64. PWM Modulation PWM Cycle Frequency PWM Cycle Duty fS/256 [PWM]/256 fS/64 for (6+2) bits mode fS/128 for (7+1) bits mode 6+2 PWM Mode Each full PWM cycle, as it is controlled by an 8-bit PWM register, has 256 clock periods. However, in the 6+2 PWM mode, each PWM cycle is subdivided into four individual sub-cycles known as modulation cycle 0~modulation cycle 3, denoted as i in the table. Each one of these four sub-cycles contains 64 clock cycles. In this mode, a modulation frequency increase of four is achieved. The 8-bit PWM register value, which represents the overall duty cycle of the PWM waveform, is divided into two groups. The first group which consists of bit2~bit7 is denoted here as the DC value. The second group which consists of bit0~bit1 is known as the AC value. In the 6+2 PWM mode, the duty cycle value of each of the four modulation sub-cycles is shown in the following table. Parameter AC (0~3) Modulation cycle i (i=0~3) DC (Duty Cycle) i<AC (DC+1)/64 i>AC DC/64 6+2 Mode Modulation Cycle Values The following diagram illustrates the waveforms associated with the 6+2 mode of PWM operation. It is important to note how the single PWM cycle is subdivided into 4 individual modulation cycles, numbered from 0~3 and how the AC value is related to the PWM value. Rev. 1.10 47 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU 6+2 PWM Mode PWM Register for 6+2 Mode 7+1 PWM Mode Each full PWM cycle, as it is controlled by an 8-bit PWM register, has 256 clock periods. However, in the 7+1 PWM mode, each PWM cycle is subdivided into two individual sub-cycles known as modulation cycle 0~modulation cycle 1, denoted as i in the table. Each one of these two sub-cycles contains 128 clock cycles. In this mode, a modulation frequency increase of two is achieved. The 8-bit PWM register value, which represents the overall duty cycle of the PWM waveform, is divided into two groups. The first group which consists of bit1~bit7 is denoted here as the DC value. The second group which consists of bit0 is known as the AC value. In the 7+1 PWM mode, the duty cycle value of each of the two modulation sub-cycles is shown in the following table. Parameter Modulation cycle i (i=0~1) AC(0~1) DC (Duty Cycle) i<AC (DC+1)/128 i>=AC DC/128 The following diagram illustrates the waveforms associated with the 7+1 mode PWM operation. It is important to note how the single PWM cycle is subdivided into 2 individual modulation cycles, numbered 0 and 1 and how the AC value is related to the PWM value. Rev. 1.10 48 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU 7+1 Mode PWM Register for 7+1 Mode PWM Output Control The PWM outputs are pin-shared with the I/O pin PA0. To operate as a PWM output and not as an I/O pin, the correct bits must be set in the CTRL0 register. A zero value must also be written to the corresponding bit in the I/O port control register PAC.0 to ensure that the corresponding PWM output pin is set as an output. After these two initial steps have been carried out, and of course after the required PWM value has been written into the PWM register, writing a high value to the corresponding bit in the output data register PA.0 will enable the PWM data to appear on the pin. Writing a zero value will disable the PWM output function and force the output low. In this way, the Port data output registers can be used as an on/off control for the PWM function. Note that if the CTRL0 register has selected the PWM function, but a high value has been written to its corresponding bit in the PAC control register to configure the pin as an input, then the pin can still function as a normal input line, with pull-high resistor options. PWM Programming Example mov mov set set clr set : : clr Rev. 1.10 a,64h pwm0,a ctrl0.5 ctrl0.3 pac.0 pa.0 ; set PWM value of decimal 100 pa.0 ; disable the PWM output_ pin PA0 forced low ; ; ; ; select the 7+1 select pin PA0 set pin PA0 as enable the PWM PWM mode to have a PWM function an output output 49 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Analog to Digital Converter The need to interface to real world analog signals is a common requirement for many electronic systems. However, to properly process these signals by a microcontroller, they must first be converted into digital signals by A/D converters. By integrating the A/D conversion electronic circuitry into the microcontroller, the need for external components is reduced significantly with the corresponding follow-on benefits of lower costs and reduced component space requirements. A/D Overview The devices contain a 4-channel analog to digital converter which can directly interface to external analog signals, such as that from sensors or other control signals and convert these signals directly into either a 12-bit digital value. The accompanying block diagram shows the overall internal structure of the A/D converter, together with its associated registers. A/D Converter Structure A/D Converter Data Registers – ADRL, ADRH The devices, which have an internal 12-bit A/D converter, require two data registers, a high byte register, known as ADRH, and a low byte register, known as ADRL. After the conversion process takes place, these registers can be directly read by the microcontroller to obtain the digitised conversion value. Only the high byte register, ADRH, utilises its full 8-bit contents. The low byte register utilises only 4 bit of its 8-bit contents as it contains only the lowest bits of the 12-bit converted value. In the following table, D0~D11 is the A/D conversion data result bits. ADRH, ADRL Register Bit ADRH 7 6 Name D11 D10 ADRL 5 4 3 2 1 0 7 6 5 4 3 2 1 0 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 — — — — R/W R R R R R R R R R R R R — — — — POR X X X X X X X X X X X X — — — — “x” unknown Unimplemented, read as “0” D11~D0: ADC conversion data Rev. 1.10 50 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU A/D Converter Control Registers – ADCR, ACSR To control the function and operation of the A/D converter, two control registers known as ADCR and ACSR are provided. These 8-bit registers define functions such as the on/off function, the selection of which analog channel is connected to the internal A/D converter, which pins are used as analog inputs and which are used as normal I/Os, the A/D clock source as well as controlling the start function and monitoring the A/D converter end of conversion status. The ACS1~ACS0 bits in the ADCR register define the channel number. As the devices contain only one actual analog to digital converter circuit, each of the individual 4 analog inputs must be routed to the converter. It is the function of the ACS1~ACS0 bits in the ADCR register to determine which analog channel is actually connected to the internal A/D converter. The PCR3~PCR0 bits contained in the ADCR register which determine which pins on PA0~PA2, PA5 are used as analog inputs for the A/D converter and which pins are to be used as normal I/O pins. If the PCRn bit has a value of 1, then the corresponding pin, namely one of the AN0~AN3 analog inputs, will be set as analog inputs. Note that if the PCRn bit is set to zero, then the corresponding pin on PA5, PA2~PA0will be set as a normal I/O pin, the analog input channels will be all disabled and the A/D converter circuitry will be powered off. The ADCR control register also contains the PCR3~PCR0 bits which determine which pins on PA5, PA2~PA0 are used as analog inputs for the A/D converter and which pins are to be used as normal I/O pins. Note that if the PCR3~PCR0 bits are all set to zero, then all the PA5, PA2~PA0 pins will be set as normal I/Os. ADCR Register Bit 7 6 5 4 3 2 1 0 Name START EOCB PCR3 PCR2 PCR1 PCR0 ACS1 ACS0 R/W R/W R R/W R/W R/W R/W R/W R/W POR 0 1 0 0 0 0 0 0 Bit 7START: Start the A/D conversion 0→1→0: Start 0→1: Reset the A/D converter and set EOCB to "1" This bit is used to initiate an A/D conversion process. The bit is normally low but if set high and then cleared low again, the A/D converter will initiate a conversion process. When the bit is set high the A/D converter will be reset. Bit 6EOCB: End of A/D conversion flag 0: A/D conversion ended 1: A/D conversion in progress This read only flag is used to indicate when an A/D conversion process has completed. When the conversion process is running the bit will be high. Bit 5~2PCR3~PCR0: PA5, PA2~PA0 pins used as analog inputs selection 0: I/O or other pin-shared function 1: Analog input If PCR3~PCR0 are all zero, the ADC circuit will be off to reduce power consumption. Bit 1~0ACS1~ACS0: A/D channel selection 00: AN0 01: AN1 10: AN2 11: AN3 Rev. 1.10 51 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU ACSR Control Register Bit 7 6 5 4 3 2 1 0 Name TEST ADONB — — — ADCS2 ADCS1 ADCS0 R/W R/W R/W — — — R/W R/W R/W POR 1 0 — — — 0 0 0 Bit 7TEST: For test mode use only Bit 6ADONB: ADC MODULE on/off control bit 0: ADC module is on 1: ADC module is off Note: 1. it is recommended to set ADONB=1 before entering sleep for saving power. 2. ADONB=1 will power down the ADC module. Bit 5~3 Unimplemented, read as "0" Bit 2~0ADCS2~ADCS0: Select ADC clock source 000: fSYS/2 001: fSYS/8 010: fSYS/32 011: Undefined 100: fSYS 101: fSYS/4 110: fSYS/16 111: Undefined These three bits are used to select the clock source for the A/D converter. A/D Operation The START bit in the register is used to start and reset the A/D converter. When the microcontroller sets this bit from low to high and then low again, an analog to digital conversion cycle will be initiated. When the START bit is brought from low to high but not low again, the EOCB bit in the ADCR register will be set to a “1” and the analog to digital converter will be reset. It is the START bit that is used to control the overall start operation of the internal analog to digital converter. The EOCB bit in the ADCR register is used to indicate when the analog to digital conversion process is complete. This bit will be automatically set to “0” by the microcontroller after a conversion cycle has ended. In addition, the corresponding A/D interrupt request flag will be set in the interrupt control register, and if the interrupts are enabled, an appropriate internal interrupt signal will be generated. This A/D internal interrupt signal will direct the program flow to the associated A/D internal interrupt address for processing. If the A/D internal interrupt is disabled, the microcontroller can be used to poll the EOCB bit in the ADCR register to check whether it has been cleared as an alternative method of detecting the end of an A/D conversion cycle. The clock source for the A/D converter, which originates from the system clock fSYS, is first divided by a division ratio, the value of which is determined by the ADCS2, ADCS1 and ADCS0 bits in the ACSR register. The A/D converter overall on/off control is a function of both the ADONB bit in the ACSR register and the PCR3~PCR0 bits in the ADCR register as shown in the table. Either the ADONB bit cleared to zero or the PCR3~PCR0 bits set to a zero value will switch off the A/D converter. These are important consideration in power sensitive applications and must be taken into account if power consumption is to be minimised. As the table illustrates, execution of the HALT instruction has no effect on the A/D converter on/off control and subsequently its power consumption. Rev. 1.10 52 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU PCR3~PCR0 Bits HALT Instruction ADONB Bit ADC On/Off =0 X X Off >0 X 0 On >0 X 1 Off "X": Don’t care A/D Converter On/Off Control Although the A/D clock source is determined by the system clock fSYS, and by bits ADCK2~ADCK0, there are some limitations on the maximum A/D clock source speed that can be selected. As the recommended range of permissible A/D clock period, tAD, is from 0.5μs to 10μs, care must be taken for system clock frequencies. For example, if the system clock operates at a frequency of 2MHz or 4MHz, the ADCS2~ADCS0 bits should not be set to 010B or 100B respectively. Doing so will give A/D clock periods that are less than the minimum A/D clock period or greater than the maximum A/D clock period which may result in inaccurate A/D conversion values. Refer to the following table for examples, where values marked with an asterisk * show where, depending upon the device, special care must be taken, as the values may be less than the specified minimum A/D Clock Period. A/D Clock Period(tAD) ADCS2, ADCS1, ADCS0 =000 (fSYS/2) ADCS2, ADCS1, ADCS0 =001 (fSYS/8) ADCS2, ADCS1, ADCS0 =010 (fSYS/32) 1MHz 2μs 8μs 2MHz 1μs 4μs 4MHz 500ns 8MHz 250ns* 12MHz 167ns* fSYS ADCS2, ADCS1, ADCS0 =100 (fSYS) ADCS2, ADCS1, ADCS0 =101 (fSYS/4) ADCS2, ADCS1, ADCS0 =110 (fSYS/16) ADCS2, ADCS1, ADCS0 =011,111 32μs* 1μs 4μs 16μs* Undefined 16μs* 500ns 2μs 8μs Undefined 2μs 8μs 250ns* 1μs 4μs Undefined 1μs 4μs 125ns* 500ns 2μs Undefined 667ns 2.67μs 83ns* 333ns* 1μs Undefined A/D Clock Period Examples A/D Input Pins All of the A/D analog input pins are pin-shared with the I/O pins on Port A. Bits PCR3~PCR0 in the ADCR register determine whether the input pins are set as normal input/output pins or whether they are set as analog inputs. In this way, pins can be changed under program control to change their function from normal I/O operation to analog inputs and vice versa. Pull-high resistors, which are set through register programming, apply to the input pins only when they are used as normal I/O pins, if set as A/D inputs the pull-high resistors will be automatically disconnected. Note that it is not necessary to first set the A/D pin as an input in the I/O port control registers to enable the A/D input as when the PCR3~PCR0 bits enable an A/D input, the status of the port control register will be overridden. Rev. 1.10 53 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Summary of A/D Conversion Steps The following summarises the individual steps that should be executed in order to implement an A/D conversion process. • Step 1 Select the required A/D conversion clock by correctly programming bits ADCS2~ADCS0 in the ACSR register. • Step 2 Select which pins are to be used as A/D inputs and configure them as A/D input pins by correctly programming the PCR3~PCR0 bits in the ADCR register. • Step 3 Enable the A/D by clearing the ADONB in the ACSR register to zero. • Step 4 Select which channel is to be connected to the internal A/D converter by correctly programming the ACS1~ACS0 bits which are also contained in the register. • Step 5 If the interrupts are to be used, the interrupt control registers must be correctly configured to ensure the A/D converter interrupt function is active. The master interrupt control bit, EMI, the INTC0 interrupt control register must be set to “1”, the A/D converter interrupt bit, ADE , must also be set to “1”. • Step 6 The analog to digital conversion process can now be initialised by setting the START bit in the ADCR register from low to high and then low again. Note that this bit should have been originally cleared to zero. • Step 7 To check when the analog to digital conversion process is complete, the EOCB bit in the ADCR register can be polled. The conversion process is complete when this bit goes low. When this occurs the A/D data registers ADRL and ADRH can be read to obtain the conversion value. As an alternative method, if the interrupts are enabled and the stack is not full, the program can wait for an A/D interrupt to occur. Note: When checking for the end of the conversion process, if the method of polling the EOCB bit in the ADCR register is used, the interrupt enable step above can be omitted. Rev. 1.10 54 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU The accompanying diagram shows graphically the various stages involved in an analog to digital conversion process and its associated timing. A/D Conversion Timing The setting up and operation of the A/D converter function is fully under the control of the application program as there are no configuration options associated with the A/D converter. After an A/D conversion process has been initiated by the application program, the microcontroller internal hardware will begin to carry out the conversion, during which time the program can continue with other functions. The time taken for the A/D conversion is 16tAD where tAD is equal to the A/D clock period. Programming Considerations When programming, the special attention must be given to the PCR [3:0] bits in the register. If these bits are all cleared to zero, no external pins will be selected for use as A/D input pins allowing the pins to be used as normal I/O pins. When this happens, the internal A/D circuitry will be power down. Setting the ADONB bit high has the ability to power down the internal A/D circuitry, which may be an important consideration in power sensitive applications. A/D Transfer Function As the device contains a 12-bit A/D converter, its full-scale converted digitised value is equal to FFFH. Since the full-scale analog input value is equal to the VDD voltage, this gives a single bit analog input value of VDD divided by 4096. The diagram shows the ideal transfer function between the analog input value and the digitised output value for the A/D converter. Note that to reduce the quantisation error, a 0.5 LSB offset is added to the A/D Converter input. Except for the digitised zero value, the subsequent digitised values will change at a point 0.5 LSB below where they would change without the offset, and the last full scale digitized value will change at a point 1.5 LSB below the VDD level. Rev. 1.10 55 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Ideal A/D Transfer Function A/D Programming Example The following two programming examples illustrate how to set and implement an A/D conversion. In the first example, the method of polling the EOCB bit in the ADCR register is used to detect when the conversion cycle is complete, whereas in the second example, the A/D interrupt is used to determine when the conversion is complete. Example: using an EOCB polling method to detect the end of conversion clr ADE mov a,00000001B mov ACSR,a mov a,00000100B mov ADCR,a : : Start_conversion: clr START set START clr START Polling_EOC: sz EOCB jmp polling_EOC mov a,ADRL mov adrl_buffer,a mov a,ADRH mov adrh_buffer,a : jmp start_conversion Rev. 1.10 ; disable ADC interrupt ; select fSYS/8 as A/D clock and ADONB=0 ; set ADCR register to configure Port as A/D inputs ; reset A/D ; start A/D ; ; ; ; ; ; poll the ADCR register EOCB bit to detect end of A/D conversion continue polling read low byte conversion result value save result to user defined register read high byte conversion result value save result to user defined register ; start next A/D conversion 56 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Example: using the interrupt method to detect the end of conversion clr ADE ; mov a,00000001B mov ACSR,a ; mov a,00000100B ; mov ADCR,a ; : : Start_conversion: clr START set START ; clr START ; clr ADF ; set ADE ; set EMI ; : : : ; ADC_: mov acc_stack,a ; mov a,STATUS mov status_stack,a ; : : mov a,ADRL ; mov adrl_buffer,a ; mov a,ADRH ; mov adrh_buffer,a ; : : EXIT_ISR: mov a,status_stack mov STATUS,a ; mov a, acc_stack ; clr ADF ; reti disable ADC interrupt select fSYS/8 as A/D clock and ADONB=0 set ADCR register to configure Port as A/D inputs and select AN0 to be connected to the A/D reset A/D start A/D clear ADC interrupt request flag enable ADC interrupt enable global interrupt ADC interrupt service routine save ACC to user defined memory save STATUS to user defined memory read save read save low byte conversion result value result to user defined register high byte conversion result value result to user defined register restore STATUS from user defined memory restore ACC from user defined memory clear ADC interrupt flag Note: To power off ADC module, it is necessary to set ADONB as “1”. Rev. 1.10 57 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Interrupts Interrupts are an important part of any microcontroller system. When an external event or an internal function such as a Timer/Event Counter requires microcontroller attention, their corresponding interrupt will enforce a temporary suspension of the main program allowing the microcontroller to direct attention to their respective needs. The device contains only one external interrupt and multiple internal interrupts. The external interrupts are controlled by the action of the external interrupt pin, while the internal interrupt is controlled by the Timer/Event Counter and the A/D converter interrupt. Interrupt Register Overall interrupt control, which means interrupt enabling and request flag setting, is controlled by using the register, INTC0. By controlling the appropriate enable bits in the register each individual interrupt can be enabled or disabled. Also when an interrupt occurs, the corresponding request flag will be set by the microcontroller. The global enable flag cleared to zero will disable all interrupts. Function Enable Bit Request Flag Global EMI — INT Pin INTE INTF Timer T0E T0F A/D Converter ADE ADF INTC0 Register Bit 7 6 5 4 3 2 1 0 Name — ADF T0F INTF ADE T0E INTE EMI R/W — R/W R/W R/W R/W R/W R/W R/W POR — 0 0 0 0 0 0 0 Bit 7 Unimplemented, read as "0" Bit 5ADF: A/D interrrupt request flag 0: No request 1: Interrupt request Bit 5T0F: Timer/Event Counter 0 interrrupt request flag 0: No request 1: Interrupt request Bit 4INTF: INT pin interrupt request flag 0: No request 1: Interrupt request Bit 3ADE: A/D interrupt control 0: Disable 1: Enable Bit 2T0E: Timer/Event Counter 0 interrupt control 0: Disable 1: Enable Bit 1INTE: INT interrupt control 0: Disable 1: Enable Bit 0EMI: Global interrupt control 0: Disable 1: Enable Rev. 1.10 58 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Interrupt Operation A Timer/Event Counter overflow, a completion of A/D conversion or an active edge on the external interrupt pin will all generate an interrupt request by setting their corresponding request flag, if their appropriate interrupt enable bit is set. When this happens, the Program Counter, which stores the address of the next instruction to be executed, will be transferred onto the stack. The Program Counter will then be loaded with a new address which will be the value of the corresponding interrupt vector. The microcontroller will then fetch its next instruction from this interrupt vector. The instruction at this vector will usually be a JMP statement which will jump to another section of program which is known as the interrupt service routine. Here is located the code to control the appropriate interrupt. The interrupt service routine must be terminated with a RETI instruction, which retrieves the original Program Counter address from the stack and allows the microcontroller to continue with normal execution at the point where the interrupt occurred. The various interrupt enable bits, together with their associated request flags, are shown in the following diagram with their order of priority. Interrupt Scheme Once an interrupt subroutine is serviced, all the other interrupts will be blocked, as the EMI bit will be cleared automatically. This will prevent any further interrupt nesting from occurring. However, if other interrupt requests occur during this interval, although the interrupt will not be immediately serviced, the request flag will still be recorded. If an interrupt requires immediate servicing while the program is already in another interrupt service routine, the EMI bit should be set after entering the routine, to allow interrupt nesting. If the stack is full, the interrupt request will not be acknowledged, even if the related interrupt is enabled, until the Stack Pointer is decremented. If immediate service is desired, the stack must be prevented from becoming full. When an interrupt request is generated it takes 2 or 3 instruction cycles before the program jumps to the interrupt vector. If the device is in the Sleep Mode and is woken up by an interrupt request then it will take 3 cycles before the program jumps to the interrupt vector. Rev. 1.10 59 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Main Pro�ram Interr�pt Req�est or Interr�pt Fla� Set by Instr�ction N Enable Bit Set ? Y ��tomatically Disable Interr�pt Clear EMI & Req�est Fla� Main Pro�ram Wait for � ~ 3 Instr�ction Cycles ISR Entry … … RETI (it will set EMI a�tomatically) Interrupt Flow Interrupt Priority Interrupts, occurring in the interval between the rising edges of two consecutive T2 pulses, will be serviced on the latter of the two T2 pulses, if the corresponding interrupts are enabled. In case of simultaneous requests, the following table shows the priority that is applied. These can be masked by resetting the EMI bit. Interrupt Source Priority Vector External interrupt 1 04H Timer/Event Counter 0 overflow 2 08H A/D converter complete 3 0CH In cases where both external and internal interrupts are enabled and where an external and internal interrupt occurs simultaneously, the external interrupt will always have priority and will therefore be serviced first. Suitable masking of the individual interrupts using the interrupt registers can prevent simultaneous occurrences. Rev. 1.10 60 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU External Interrupt For an external interrupt to occur, the global interrupt enable bit, EMI, and external interrupt enable bit, INTE, must first be set. An actual external interrupt will take place when the external interrupt request flag, INTF is set, a situation that will occur when an edge transition appears on the external INT line. The type of transition that will trigger an external interrupt, whether high to low, low to high or both is determined by the INTES0 and INTES1 bits, which are bits 6 and 7 respectively in the CTRL1 control register. These two bits can also disable the external interrupt function. INTES1 INTES0 Request Flag 0 0 External interrupt disable 0 1 Rising edge trigger 1 0 Falling edge trigger 1 1 Dual edge trigger The external interrupt pin is pin-shared with the I/O pin PA2 and can only be used as an external interrupt pin if the corresponding external interrupt enable bit in the INTC0 register has been set and the edge trigger type has been selected using the CTRL1 register. The pin must also be set as an input by setting the corresponding PAC.2 bit in the port control register. When the interrupt is enabled, the stack is not full and a transition appears on the external interrupt pin, a subroutine call to the external interrupt vector at location 04H, will take place. When the interrupt is serviced, the external interrupt request flag, INTF, will be automatically reset and the EMI bit will be automatically cleared to disable other interrupts. Note that any pull-high resistor connections on this pin will remain valid even if the pin is used as an external interrupt input Timer/Event Counter Interrupt For a Timer/Event Counter interrupt to occur, the global interrupt enable bit, EMI and the corresponding timer interrupt enable bit T0E must first be set. An actual Timer/Event Counter interrupt will take place when the Timer/Event Counter request flag T0F is set, a situation that will occur when the relevant Timer/Event Counter overflows. When the interrupt is enabled, the stack is not full and a Timer/Event Counter overflow occurs, a subroutine call to the relevant timer interrupt vector, will take place. When the interrupt is serviced, the timer interrupt request flag T0F will be automatically reset and the EMI bit will be automatically cleared to disable other interrupts. A/D Converter Interrupt The devices include A/D interrupt. For an A/D interrupt to occur, the global interrupt enable bit EMI and the corresponding interrupt enable bit ADE must be first set. An actual A/D interrupt will take place when the A/D converter request flag ADF is set, a situation that will occur when an A/D conversion process has completed. When the interrupt is enabled, the stack is not full and an A/D conversion process finishes execution, a subroutine call to the relevant A/D interrupt vector, will take place. When the interrupt is serviced, the A/D interrupt request flag ADF will be automatically reset and the EMI bit will be automatically cleared to disable other interrupts. As this interrupt vector location is shared with other interrupts, to be effective it must be selected via configuration option. Rev. 1.10 61 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Interrupt Wake-up Function Each of the interrupt functions has the capability of waking up the microcontroller when in the Sleep Mode. A wake-up is generated when an interrupt request flag changes from low to high and is independent of whether the interrupt is enabled or not. Therefore, even though the device is in the Sleep Mode and its system oscillator is stopped, situations such as external edge transitions on the external interrupt pins, a low power supply voltage or may cause their respective interrupt flag to be set high and consequently generate an interrupt. Care must therefore be taken if spurious wake-up situations are to be avoided. If an interrupt wake-up function is to be disabled then the corresponding interrupt request flag should be set high before the device enters the Sleep Mode. The interrupt enable bits have no effect on the interrupt wake-up function. Programming Considerations By disabling the relevant interrupt enable bits, a requested interrupt can be prevented from being serviced, however, once an interrupt request flag is set, it will remain in this condition in the interrupt register until the corresponding interrupt is serviced or until the request flag is cleared by the application program. It is recommended that programs do not use the “CALL” instruction within the interrupt service subroutine. Interrupts often occur in an unpredictable manner or need to be serviced immediately. If only one stack is left and the interrupt is not well controlled, the original control sequence will be damaged once a CALL subroutine is executed in the interrupt subroutine. All of these interrupts have the capability of waking up the microcontroller when it is in Sleep Mode, the wake up being generated when the interrupt request flag changes from low to high. If it is required to prevent a certain interrupt from waking up the microcontroller then its respective request flag should be first set high before entering the Sleep Mode. As only the Program Counter is pushed onto the stack, then if the contents of the accumulator, status register or other registers are altered by the interrupt service program, which may corrupt the desired control sequence, then the contents should be saved in advance. To return from an interrupt subroutine, either a RET or RETI instruction may be executed. The RETI instruction in addition to executing a return to the main program also automatically sets the EMI bit high to allow further interrupts. The RET instruction however only executes a return to the main program leaving the EMI bit in its present zero state and therefore disabling the execution of further interrupts. Application Circuits V D D 0 .0 1 F * * 0 .1 F 1 N 4 1 4 8 * 0 .1 ~ 1 F V D D 1 0 k ~ 1 0 0 k 3 0 0 R E S /P A 7 P A 0 /P W M /A N P A 1 /T M R /A N P A 2 /IN T /A N P A P A P A 5 /A N P A 6 /P F 0 2 1 3 4 D 3 P C 0 ~ P C 5 V S S Rev. 1.10 62 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Instruction Set Introduction Central to the successful operation of any microcontroller is its instruction set, which is a set of program instruction codes that directs the microcontroller to perform certain operations. In the case of Holtek microcontroller, a comprehensive and flexible set of over 60 instructions is provided to enable programmers to implement their application with the minimum of programming overheads. For easier understanding of the various instruction codes, they have been subdivided into several functional groupings. Instruction Timing Most instructions are implemented within one instruction cycle. The exceptions to this are branch, call, or table read instructions where two instruction cycles are required. One instruction cycle is equal to 4 system clock cycles, therefore in the case of an 8MHz system oscillator, most instructions would be implemented within 0.5μs and branch or call instructions would be implemented within 1μs. Although instructions which require one more cycle to implement are generally limited to the JMP, CALL, RET, RETI and table read instructions, it is important to realize that any other instructions which involve manipulation of the Program Counter Low register or PCL will also take one more cycle to implement. As instructions which change the contents of the PCL will imply a direct jump to that new address, one more cycle will be required. Examples of such instructions would be “CLR PCL” or “MOV PCL, A”. For the case of skip instructions, it must be noted that if the result of the comparison involves a skip operation then this will also take one more cycle, if no skip is involved then only one cycle is required. Moving and Transferring Data The transfer of data within the microcontroller program is one of the most frequently used operations. Making use of three kinds of MOV instructions, data can be transferred from registers to the Accumulator and vice-versa as well as being able to move specific immediate data directly into the Accumulator. One of the most important data transfer applications is to receive data from the input ports and transfer data to the output ports. Arithmetic Operations The ability to perform certain arithmetic operations and data manipulation is a necessary feature of most microcontroller applications. Within the Holtek microcontroller instruction set are a range of add and subtract instruction mnemonics to enable the necessary arithmetic to be carried out. Care must be taken to ensure correct handling of carry and borrow data when results exceed 255 for addition and less than 0 for subtraction. The increment and decrement instructions INC, INCA, DEC and DECA provide a simple means of increasing or decreasing by a value of one of the values in the destination specified. Rev. 1.10 63 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Logical and Rotate Operation The standard logical operations such as AND, OR, XOR and CPL all have their own instruction within the Holtek microcontroller instruction set. As with the case of most instructions involving data manipulation, data must pass through the Accumulator which may involve additional programming steps. In all logical data operations, the zero flag may be set if the result of the operation is zero. Another form of logical data manipulation comes from the rotate instructions such as RR, RL, RRC and RLC which provide a simple means of rotating one bit right or left. Different rotate instructions exist depending on program requirements. Rotate instructions are useful for serial port programming applications where data can be rotated from an internal register into the Carry bit from where it can be examined and the necessary serial bit set high or low. Another application which rotate data operations are used is to implement multiplication and division calculations. Branches and Control Transfer Program branching takes the form of either jumps to specified locations using the JMP instruction or to a subroutine using the CALL instruction. They differ in the sense that in the case of a subroutine call, the program must return to the instruction immediately when the subroutine has been carried out. This is done by placing a return instruction “RET” in the subroutine which will cause the program to jump back to the address right after the CALL instruction. In the case of a JMP instruction, the program simply jumps to the desired location. There is no requirement to jump back to the original jumping off point as in the case of the CALL instruction. One special and extremely useful set of branch instructions are the conditional branches. Here a decision is first made regarding the condition of a certain data memory or individual bits. Depending upon the conditions, the program will continue with the next instruction or skip over it and jump to the following instruction. These instructions are the key to decision making and branching within the program perhaps determined by the condition of certain input switches or by the condition of internal data bits. Bit Operations The ability to provide single bit operations on Data Memory is an extremely flexible feature of all Holtek microcontrollers. This feature is especially useful for output port bit programming where individual bits or port pins can be directly set high or low using either the “SET [m].i” or “CLR [m].i” instructions respectively. The feature removes the need for programmers to first read the 8-bit output port, manipulate the input data to ensure that other bits are not changed and then output the port with the correct new data. This read-modify-write process is taken care of automatically when these bit operation instructions are used. Table Read Operations Data storage is normally implemented by using registers. However, when working with large amounts of fixed data, the volume involved often makes it inconvenient to store the fixed data in the Data Memory. To overcome this problem, Holtek microcontrollers allow an area of Program Memory to be set as a table where data can be directly stored. A set of easy to use instructions provides the means by which this fixed data can be referenced and retrieved from the Program Memory. Other Operations In addition to the above functional instructions, a range of other instructions also exist such as the “HALT” instruction for Power-down operations and instructions to control the operation of the Watchdog Timer for reliable program operations under extreme electric or electromagnetic environments. For their relevant operations, refer to the functional related sections. Rev. 1.10 64 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Instruction Set Summary The following table depicts a summary of the instruction set categorised according to function and can be consulted as a basic instruction reference using the following listed conventions. Table Conventions x: Bits immediate data m: Data Memory address A: Accumulator i: 0~7 number of bits addr: Program memory address Mnemonic Description Cycles Flag Affected Add Data Memory to ACC Add ACC to Data Memory Add immediate data to ACC Add Data Memory to ACC with Carry Add ACC to Data memory with Carry Subtract immediate data from the ACC Subtract Data Memory from ACC Subtract Data Memory from ACC with result in Data Memory Subtract Data Memory from ACC with Carry Subtract Data Memory from ACC with Carry, result in Data Memory Decimal adjust ACC for Addition with result in Data Memory 1 1Note 1 1 1Note 1 1 1Note 1 1Note 1Note Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV C 1 1 1 1Note 1Note 1Note 1 1 1 1Note 1 Z Z Z Z Z Z Z Z Z Z Z Increment Data Memory with result in ACC Increment Data Memory Decrement Data Memory with result in ACC Decrement Data Memory 1 1Note 1 1Note Z Z Z Z Rotate Data Memory right with result in ACC Rotate Data Memory right Rotate Data Memory right through Carry with result in ACC Rotate Data Memory right through Carry Rotate Data Memory left with result in ACC Rotate Data Memory left Rotate Data Memory left through Carry with result in ACC Rotate Data Memory left through Carry 1 1Note 1 1Note 1 1Note 1 1Note None None C C None None C C Arithmetic ADD A,[m] ADDM A,[m] ADD A,x ADC A,[m] ADCM A,[m] SUB A,x SUB A,[m] SUBM A,[m] SBC A,[m] SBCM A,[m] DAA [m] Logic Operation AND A,[m] OR A,[m] XOR A,[m] ANDM A,[m] ORM A,[m] XORM A,[m] AND A,x OR A,x XOR A,x CPL [m] CPLA [m] Logical AND Data Memory to ACC Logical OR Data Memory to ACC Logical XOR Data Memory to ACC Logical AND ACC to Data Memory Logical OR ACC to Data Memory Logical XOR ACC to Data Memory Logical AND immediate Data to ACC Logical OR immediate Data to ACC Logical XOR immediate Data to ACC Complement Data Memory Complement Data Memory with result in ACC Increment & Decrement INCA [m] INC [m] DECA [m] DEC [m] Rotate RRA [m] RR [m] RRCA [m] RRC [m] RLA [m] RL [m] RLCA [m] RLC [m] Rev. 1.10 65 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Mnemonic Description Cycles Flag Affected Move Data Memory to ACC Move ACC to Data Memory Move immediate data to ACC 1 1Note 1 None None None Clear bit of Data Memory Set bit of Data Memory 1Note 1Note None None Jump unconditionally Skip if Data Memory is zero Skip if Data Memory is zero with data movement to ACC Skip if bit i of Data Memory is zero Skip if bit i of Data Memory is not zero Skip if increment Data Memory is zero Skip if decrement Data Memory is zero Skip if increment Data Memory is zero with result in ACC Skip if decrement Data Memory is zero with result in ACC Subroutine call Return from subroutine Return from subroutine and load immediate data to ACC Return from interrupt 2 1Note 1Note 1Note 1Note 1Note 1Note 1Note 1Note 2 2 2 2 None None None None None None None None None None None None None Read table (specific page) to TBLH and Data Memory Read table (current page) to TBLH and Data Memory Read table (last page) to TBLH and Data Memory 2Note 2Note 2Note None None None No operation Clear Data Memory Set Data Memory Clear Watchdog Timer Pre-clear Watchdog Timer Pre-clear Watchdog Timer Swap nibbles of Data Memory Swap nibbles of Data Memory with result in ACC Enter power down mode 1 1Note 1Note 1 1 1 1Note 1 1 None None None TO, PDF TO, PDF TO, PDF None None TO, PDF Data Move MOV A,[m] MOV [m],A MOV A,x Bit Operation CLR [m].i SET [m].i Branch Operation JMP addr SZ [m] SZA [m] SZ [m].i SNZ [m].i SIZ [m] SDZ [m] SIZA [m] SDZA [m] CALL addr RET RET A,x RETI Table Read Operation TABRD [m] TABRDC [m] TABRDL [m] Miscellaneous NOP CLR [m] SET [m] CLR WDT CLR WDT1 CLR WDT2 SWAP [m] SWAPA [m] HALT Note: 1. For skip instructions, if the result of the comparison involves a skip then two cycles are required, if no skip takes place only one cycle is required. 2. Any instruction which changes the contents of the PCL will also require 2 cycles for execution. 3. For the “CLR WDT1” and “CLR WDT2” instructions the TO and PDF flags may be affected by the execution status. The TO and PDF flags are cleared after both “CLR WDT1” and “CLR WDT2” instructions are consecutively executed. Otherwise the TO and PDF flags remain unchanged. Rev. 1.10 66 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Instruction Definition ADC A,[m] Description Operation Affected flag(s) Add Data Memory to ACC with Carry The contents of the specified Data Memory, Accumulator and the carry flag are added. The result is stored in the Accumulator. ACC ← ACC + [m] + C OV, Z, AC, C ADCM A,[m] Description Operation Affected flag(s) Add ACC to Data Memory with Carry The contents of the specified Data Memory, Accumulator and the carry flag are added. The result is stored in the specified Data Memory. [m] ← ACC + [m] + C OV, Z, AC, C Add Data Memory to ACC ADD A,[m] Description The contents of the specified Data Memory and the Accumulator are added. The result is stored in the Accumulator. Operation Affected flag(s) ACC ← ACC + [m] OV, Z, AC, C ADD A,x Description Operation Affected flag(s) Add immediate data to ACC The contents of the Accumulator and the specified immediate data are added. The result is stored in the Accumulator. ACC ← ACC + x OV, Z, AC, C ADDM A,[m] Description Operation Affected flag(s) Add ACC to Data Memory The contents of the specified Data Memory and the Accumulator are added. The result is stored in the specified Data Memory. [m] ← ACC + [m] OV, Z, AC, C AND A,[m] Description Operation Affected flag(s) Logical AND Data Memory to ACC Data in the Accumulator and the specified Data Memory perform a bitwise logical AND operation. The result is stored in the Accumulator. ACC ← ACC ″AND″ [m] Z AND A,x Description Operation Affected flag(s) Logical AND immediate data to ACC Data in the Accumulator and the specified immediate data perform a bit wise logical AND operation. The result is stored in the Accumulator. ACC ← ACC ″AND″ x Z ANDM A,[m] Description Operation Affected flag(s) Logical AND ACC to Data Memory Data in the specified Data Memory and the Accumulator perform a bitwise logical AND operation. The result is stored in the Data Memory. [m] ← ACC ″AND″ [m] Z Rev. 1.10 67 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU CALL addr Description Operation Affected flag(s) Subroutine call Unconditionally calls a subroutine at the specified address. The Program Counter then increments by 1 to obtain the address of the next instruction which is then pushed onto the stack. The specified address is then loaded and the program continues execution from this new address. As this instruction requires an additional operation, it is a two cycle instruction. Stack ← Program Counter + 1 Program Counter ← addr None CLR [m] Description Operation Affected flag(s) Clear Data Memory Each bit of the specified Data Memory is cleared to 0. [m] ← 00H None CLR [m].i Description Operation Affected flag(s) Clear bit of Data Memory Bit i of the specified Data Memory is cleared to 0. [m].i ← 0 None CLR WDT Description Operation Affected flag(s) Clear Watchdog Timer The TO, PDF flags and the WDT are all cleared. WDT cleared TO ← 0 PDF ← 0 TO, PDF CLR WDT1 Description Operation Affected flag(s) Pre-clear Watchdog Timer The TO, PDF flags and the WDT are all cleared. Note that this instruction works in conjunction with CLR WDT2 and must be executed alternately with CLR WDT2 to have effect. Repetitively executing this instruction without alternately executing CLR WDT2 will have no effect. WDT cleared TO ← 0 PDF ← 0 TO, PDF CLR WDT2 Description Operation Affected flag(s) Pre-clear Watchdog Timer The TO, PDF flags and the WDT are all cleared. Note that this instruction works in conjunction with CLR WDT1 and must be executed alternately with CLR WDT1 to have effect. Repetitively executing this instruction without alternately executing CLR WDT1 will have no effect. WDT cleared TO ← 0 PDF ← 0 TO, PDF CPL [m] Description Operation Affected flag(s) Complement Data Memory Each bit of the specified Data Memory is logically complemented (1′s complement). Bits which previously contained a 1 are changed to 0 and vice versa. [m] ← [m] Z Rev. 1.10 68 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU CPLA [m] Description Operation Affected flag(s) Complement Data Memory with result in ACC Each bit of the specified Data Memory is logically complemented (1′s complement). Bits which previously contained a 1 are changed to 0 and vice versa. The complemented result is stored in the Accumulator and the contents of the Data Memory remain unchanged. ACC ← [m] Z DAA [m] Description Operation Affected flag(s) Decimal-Adjust ACC for addition with result in Data Memory Convert the contents of the Accumulator value to a BCD (Binary Coded Decimal) value resulting from the previous addition of two BCD variables. If the low nibble is greater than 9 or if AC flag is set, then a value of 6 will be added to the low nibble. Otherwise the low nibble remains unchanged. If the high nibble is greater than 9 or if the C flag is set, then a value of 6 will be added to the high nibble. Essentially, the decimal conversion is performed by adding 00H, 06H, 60H or 66H depending on the Accumulator and flag conditions. Only the C flag may be affected by this instruction which indicates that if the original BCD sum is greater than 100, it allows multiple precision decimal addition. [m] ← ACC + 00H or [m] ← ACC + 06H or [m] ← ACC + 60H or [m] ← ACC + 66H C DEC [m] Description Operation Affected flag(s) Decrement Data Memory Data in the specified Data Memory is decremented by 1. [m] ← [m] − 1 Z DECA [m] Description Operation Affected flag(s) Decrement Data Memory with result in ACC Data in the specified Data Memory is decremented by 1. The result is stored in the Accumulator. The contents of the Data Memory remain unchanged. ACC ← [m] − 1 Z HALT Description Operation Affected flag(s) Enter power down mode This instruction stops the program execution and turns off the system clock. The contents of the Data Memory and registers are retained. The WDT and prescaler are cleared. The power down flag PDF is set and the WDT time-out flag TO is cleared. TO ← 0 PDF ← 1 TO, PDF INC [m] Description Operation Affected flag(s) Increment Data Memory Data in the specified Data Memory is incremented by 1. [m] ← [m] + 1 Z INCA [m] Description Operation Affected flag(s) Increment Data Memory with result in ACC Data in the specified Data Memory is incremented by 1. The result is stored in the Accumulator. The contents of the Data Memory remain unchanged. ACC ← [m] + 1 Z Rev. 1.10 69 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU JMP addr Description Operation Affected flag(s) Jump unconditionally The contents of the Program Counter are replaced with the specified address. Program execution then continues from this new address. As this requires the insertion of a dummy instruction while the new address is loaded, it is a two cycle instruction. Program Counter ← addr None MOV A,[m] Description Operation Affected flag(s) Move Data Memory to ACC The contents of the specified Data Memory are copied to the Accumulator. ACC ← [m] None MOV A,x Description Operation Affected flag(s) Move immediate data to ACC The immediate data specified is loaded into the Accumulator. ACC ← x None MOV [m],A Description Operation Affected flag(s) Move ACC to Data Memory The contents of the Accumulator are copied to the specified Data Memory. [m] ← ACC None NOP Description Operation Affected flag(s) No operation No operation is performed. Execution continues with the next instruction. No operation None OR A,[m] Description Operation Affected flag(s) Logical OR Data Memory to ACC Data in the Accumulator and the specified Data Memory perform a bitwise logical OR operation. The result is stored in the Accumulator. ACC ← ACC ″OR″ [m] Z OR A,x Description Operation Affected flag(s) Logical OR immediate data to ACC Data in the Accumulator and the specified immediate data perform a bitwise logical OR operation. The result is stored in the Accumulator. ACC ← ACC ″OR″ x Z ORM A,[m] Description Operation Affected flag(s) Logical OR ACC to Data Memory Data in the specified Data Memory and the Accumulator perform a bitwise logical OR operation. The result is stored in the Data Memory. [m] ← ACC ″OR″ [m] Z RET Description Operation Affected flag(s) Return from subroutine The Program Counter is restored from the stack. Program execution continues at the restored address. Program Counter ← Stack None Rev. 1.10 70 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU RET A,x Description Operation Affected flag(s) Return from subroutine and load immediate data to ACC The Program Counter is restored from the stack and the Accumulator loaded with the specified immediate data. Program execution continues at the restored address. Program Counter ← Stack ACC ← x None RETI Description Operation Affected flag(s) Return from interrupt The Program Counter is restored from the stack and the interrupts are re-enabled by setting the EMI bit. EMI is the master interrupt global enable bit. If an interrupt was pending when the RETI instruction is executed, the pending Interrupt routine will be processed before returning to the main program. Program Counter ← Stack EMI ← 1 None RL [m] Description Operation Affected flag(s) Rotate Data Memory left The contents of the specified Data Memory are rotated left by 1 bit with bit 7 rotated into bit 0. [m].(i+1) ← [m].i; (i=0~6) [m].0 ← [m].7 None RLA [m] Description Operation Affected flag(s) Rotate Data Memory left with result in ACC The contents of the specified Data Memory are rotated left by 1 bit with bit 7 rotated into bit 0. The rotated result is stored in the Accumulator and the contents of the Data Memory remain unchanged. ACC.(i+1) ← [m].i; (i=0~6) ACC.0 ← [m].7 None RLC [m] Description Operation Affected flag(s) Rotate Data Memory left through Carry The contents of the specified Data Memory and the carry flag are rotated left by 1 bit. Bit 7 replaces the Carry bit and the original carry flag is rotated into bit 0. [m].(i+1) ← [m].i; (i=0~6) [m].0 ← C C ← [m].7 C RLCA [m] Description Operation Affected flag(s) Rotate Data Memory left through Carry with result in ACC Data in the specified Data Memory and the carry flag are rotated left by 1 bit. Bit 7 replaces the Carry bit and the original carry flag is rotated into the bit 0. The rotated result is stored in the Accumulator and the contents of the Data Memory remain unchanged. ACC.(i+1) ← [m].i; (i=0~6) ACC.0 ← C C ← [m].7 C RR [m] Description Operation Affected flag(s) Rotate Data Memory right The contents of the specified Data Memory are rotated right by 1 bit with bit 0 rotated into bit 7. [m].i ← [m].(i+1); (i=0~6) [m].7 ← [m].0 None Rev. 1.10 71 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU RRA [m] Description Operation Affected flag(s) Rotate Data Memory right with result in ACC Data in the specified Data Memory and the carry flag are rotated right by 1 bit with bit 0 rotated into bit 7. The rotated result is stored in the Accumulator and the contents of the Data Memory remain unchanged. ACC.i ← [m].(i+1); (i=0~6) ACC.7 ← [m].0 None RRC [m] Description Operation Affected flag(s) Rotate Data Memory right through Carry The contents of the specified Data Memory and the carry flag are rotated right by 1 bit. Bit 0 replaces the Carry bit and the original carry flag is rotated into bit 7. [m].i ← [m].(i+1); (i=0~6) [m].7 ← C C ← [m].0 C RRCA [m] Description Operation Affected flag(s) Rotate Data Memory right through Carry with result in ACC Data in the specified Data Memory and the carry flag are rotated right by 1 bit. Bit 0 replaces the Carry bit and the original carry flag is rotated into bit 7. The rotated result is stored in the Accumulator and the contents of the Data Memory remain unchanged. ACC.i ← [m].(i+1); (i=0~6) ACC.7 ← C C ← [m].0 C SBC A,[m] Description Operation Affected flag(s) Subtract Data Memory from ACC with Carry The contents of the specified Data Memory and the complement of the carry flag are subtracted from the Accumulator. The result is stored in the Accumulator. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1. ACC ← ACC − [m] − C OV, Z, AC, C SBCM A,[m] Description Operation Affected flag(s) Subtract Data Memory from ACC with Carry and result in Data Memory The contents of the specified Data Memory and the complement of the carry flag are subtracted from the Accumulator. The result is stored in the Data Memory. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1. [m] ← ACC − [m] − C OV, Z, AC, C SDZ [m] Description Operation Affected flag(s) Skip if decrement Data Memory is 0 The contents of the specified Data Memory are first decremented by 1. If the result is 0 the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program proceeds with the following instruction. [m] ← [m] − 1 Skip if [m]=0 None Rev. 1.10 72 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU SDZA [m] Description Operation Affected flag(s) Skip if decrement Data Memory is zero with result in ACC The contents of the specified Data Memory are first decremented by 1. If the result is 0, the following instruction is skipped. The result is stored in the Accumulator but the specified Data Memory contents remain unchanged. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0, the program proceeds with the following instruction. ACC ← [m] − 1 Skip if ACC=0 None SET [m] Description Operation Affected flag(s) Set Data Memory Each bit of the specified Data Memory is set to 1. [m] ← FFH None SET [m].i Description Operation Affected flag(s) Set bit of Data Memory Bit i of the specified Data Memory is set to 1. [m].i ← 1 None SIZ [m] Description Operation Affected flag(s) Skip if increment Data Memory is 0 The contents of the specified Data Memory are first incremented by 1. If the result is 0, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program proceeds with the following instruction. [m] ← [m] + 1 Skip if [m]=0 None SIZA [m] Description Operation Affected flag(s) Skip if increment Data Memory is zero with result in ACC The contents of the specified Data Memory are first incremented by 1. If the result is 0, the following instruction is skipped. The result is stored in the Accumulator but the specified Data Memory contents remain unchanged. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program proceeds with the following instruction. ACC ← [m] + 1 Skip if ACC=0 None SNZ [m].i Description Operation Affected flag(s) Skip if bit i of Data Memory is not 0 If bit i of the specified Data Memory is not 0, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is 0 the program proceeds with the following instruction. Skip if [m].i ≠ 0 None SUB A,[m] Description Operation Affected flag(s) Subtract Data Memory from ACC The specified Data Memory is subtracted from the contents of the Accumulator. The result is stored in the Accumulator. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1. ACC ← ACC − [m] OV, Z, AC, C Rev. 1.10 73 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU SUBM A,[m] Description Operation Affected flag(s) Subtract Data Memory from ACC with result in Data Memory The specified Data Memory is subtracted from the contents of the Accumulator. The result is stored in the Data Memory. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1. [m] ← ACC − [m] OV, Z, AC, C SUB A,x Description Operation Affected flag(s) Subtract immediate data from ACC The immediate data specified by the code is subtracted from the contents of the Accumulator. The result is stored in the Accumulator. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1. ACC ← ACC − x OV, Z, AC, C SWAP [m] Description Operation Affected flag(s) Swap nibbles of Data Memory The low-order and high-order nibbles of the specified Data Memory are interchanged. [m].3~[m].0 ↔ [m].7~[m].4 None SWAPA [m] Description Operation Affected flag(s) Swap nibbles of Data Memory with result in ACC The low-order and high-order nibbles of the specified Data Memory are interchanged. The result is stored in the Accumulator. The contents of the Data Memory remain unchanged. ACC.3~ACC.0 ← [m].7~[m].4 ACC.7~ACC.4 ← [m].3~[m].0 None SZ [m] Description Operation Affected flag(s) Skip if Data Memory is 0 If the contents of the specified Data Memory is 0, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program proceeds with the following instruction. Skip if [m]=0 None SZA [m] Description Operation Affected flag(s) Skip if Data Memory is 0 with data movement to ACC The contents of the specified Data Memory are copied to the Accumulator. If the value is zero, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program proceeds with the following instruction. ACC ← [m] Skip if [m]=0 None SZ [m].i Description Operation Affected flag(s) Skip if bit i of Data Memory is 0 If bit i of the specified Data Memory is 0, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0, the program proceeds with the following instruction. Skip if [m].i=0 None Rev. 1.10 74 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU TABRD [m] Description Operation Affected flag(s) Read table (specific page) to TBLH and Data Memory The low byte of the program code (specific page) addressed by the table pointer pair (TBHP and TBLP) is moved to the specified Data Memory and the high byte moved to TBLH. [m] ← program code (low byte) TBLH ← program code (high byte) None TABRDC [m] Description Operation Affected flag(s) Read table (current page) to TBLH and Data Memory The low byte of the program code (current page) addressed by the table pointer (TBLP) is moved to the specified Data Memory and the high byte moved to TBLH. [m] ← program code (low byte) TBLH ← program code (high byte) None TABRDL [m] Description Operation Affected flag(s) Read table (last page) to TBLH and Data Memory The low byte of the program code (last page) addressed by the table pointer (TBLP) is moved to the specified Data Memory and the high byte moved to TBLH. [m] ← program code (low byte) TBLH ← program code (high byte) None XOR A,[m] Description Operation Affected flag(s) Logical XOR Data Memory to ACC Data in the Accumulator and the specified Data Memory perform a bitwise logical XOR operation. The result is stored in the Accumulator. ACC ← ACC ″XOR″ [m] Z XORM A,[m] Description Operation Affected flag(s) Logical XOR ACC to Data Memory Data in the specified Data Memory and the Accumulator perform a bitwise logical XOR operation. The result is stored in the Data Memory. [m] ← ACC ″XOR″ [m] Z XOR A,x Description Operation Affected flag(s) Logical XOR immediate data to ACC Data in the Accumulator and the specified immediate data perform a bitwise logical XOR operation. The result is stored in the Accumulator. ACC ← ACC ″XOR″ x Z Rev. 1.10 75 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Package Information Note that the package information provided here is for consultation purposes only. As this information may be updated at regular intervals users are reminded to consult the Holtek website for the latest version of the package information. Additional supplementary information with regard to packaging is listed below. Click on the relevant section to be transferred to the relevant website page. • Further Package Information (include Outline Dimensions, Product Tape and Reel Specifications) • Packing Meterials Information • Carton information Rev. 1.10 76 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU 8-pin DIP (300mil) Outline Dimensions Symbol Nom. Max. A 0.355 0.365 0.400 B 0.240 0.250 0.280 C 0.115 0.130 0.195 D 0.115 0.130 0.150 E 0.014 0.018 0.022 F 0.045 0.060 0.070 G — 0.100 BSC — H 0.300 0.310 0.325 I — — 0.430 Symbol Rev. 1.10 Dimensions in inch Min. Dimensions in mm Min. Nom. Max. A 9.02 9.27 10.16 B 6.10 6.35 7.11 C 2.92 3.30 4.95 D 2.92 3.30 3.81 E 0.36 0.46 0.56 F 1.14 1.52 1.78 G — 2.54 BSC — H 7.26 7.87 8.26 I — — 10.92 77 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU 8-pin SOP (150mil) Outline Dimensions Symbol Dimensions in inch Min. Nom. Max. — A — 0.236 BSC B — 0.154 BSC — C 0.012 — 0.020 C′ — 0.193 BSC — D — — 0.069 E — 0.050 BSC — F 0.004 — 0.010 G 0.016 — 0.050 H 0.004 — 0.010 α 0° — 8° Symbol Rev. 1.10 Dimensions in mm Min. Nom. Max. — A — 6.00 BSC B — 3.90 BSC — C 0.31 — 0.51 C′ — 4.90 BSC — D — — 1.75 E — 1.27 BSC — F 0.10 — 0.25 G 0.40 — 1.27 H 0.10 — 0.25 α 0° — 8° 78 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU 10-pin MSOP Outline Dimensions Symbol Min. Nom. Max. A — — 0.043 A1 0.000 — 0.006 A2 0.030 0.033 0.037 B 0.007 — 0.013 C 0.003 — 0.009 D — 0.118 BSC — E — 0.193 BSC — E1 — 0.118 BSC — e — 0.020 BSC — L 0.016 0.024 0.031 L1 — 0.037 BSC — y — 0.004 — θ 0° — 8° Symbol Rev. 1.10 Dimensions in inch Dimensions in mm Min. Nom. Max. A — — 1.10 A1 0.00 — 0.15 A2 0.75 0.85 0.95 B 0.17 — 0.33 C 0.08 — 0.23 D — 3.00 BSC — E — 4.90 BSC — E1 — 3.00 BSC — e — 0.50 BSC — L 0.40 0.60 0.80 L1 — 0.95 BSC — y — 0.10 — θ 0° — 8° 79 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU 16-pin DIP (300mil) Outline Dimensions Fig1. Full Lead Packages Fig2. 1/2 Lead Packages See Fig 1 Symbol Min. Nom. Max. A 0.780 0.790 0.800 B 0.240 0.250 0.280 C 0.115 0.130 0.195 D 0.115 0.130 0.150 E 0.014 0.018 0.022 F 0.045 0.060 0.070 G — 0.100 BSC — H 0.300 0.310 0.325 I — — 0.430 Symbol Rev. 1.10 Dimensions in inch Dimensions in mm Min. Nom. Max. 20.32 A 19.81 20.07 B 6.10 6.35 7.11 C 2.92 3.30 4.95 D 2.92 3.30 3.81 E 0.36 0.46 0.56 F 1.14 1.52 1.78 G — 2.54 BSC — H 7.62 7.87 8.26 I — — 10.92 80 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU See Fig 2 − Type 1 Symbol Dimensions in inch Min. Nom. Max. A 0.745 0.765 0.785 B 0.275 0.285 0.295 C 0.120 0.135 0.150 D 0.110 0.130 0.150 E 0.014 0.018 0.022 F 0.045 0.050 0.060 G — 0.1 BSC — H 0.300 0.310 0.325 I — — 0.430 Symbol Dimensions in mm Min. Nom. Max. A 18.92 19.43 19.94 B 6.99 7.24 7.49 C 3.05 3.43 3.81 D 2.79 3.30 3.81 E 0.36 0.46 0.56 F 1.14 1.27 1.52 G — 2.54 BSC — H 7.62 7.87 8.26 I — — 10.92 See Fig 2 − Type 2 Symbol Nom. Max. A 0.735 0.755 0.775 B 0.240 0.250 0.280 C 0.115 0.130 0.195 D 0.115 0.130 0.150 E 0.014 0.018 0.022 F 0.045 0.060 0.070 G — 0.1 BSC — H 0.300 0.310 0.325 I — — 0.430 Symbol Rev. 1.10 Dimensions in inch Min. Dimensions in mm Min. Nom. Max. A 18.67 19.18 19.69 B 6.10 6.35 7.11 C 2.92 3.30 4.95 D 2.92 3.30 3.81 E 0.36 0.46 0.56 F 1.14 1.52 1.78 G — 2.54 BSC — H 7.62 7.87 8.26 I — — 10.92 81 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU 16-pin NSOP (150mil) Outline Dimensions Symbol Dimensions in inch Min. Nom. Max. A — 0.236 BSC — B — 0.154 BSC — 0.020 C 0.012 — C' — 0.390 BSC — D — — 0.069 E — 0.050 BSC — F 0.004 — 0.010 G 0.016 — 0.050 H 0.004 — 0.010 α 0° ― 8° Symbol Rev. 1.10 Dimensions in mm Min. Nom. Max. — A — 6 BSC B — 3.9 BSC — C 0.31 — 0.51 C' — 9.9 BSC — D — — 1.75 E — 1.27 BSC — F 0.10 — 0.25 G 0.40 — 1.27 H 0.10 — 0.25 α 0° ― 8° 82 August 01, 2014 HT46R002/HT46R003 Cost-Effective A/D 8-Bit OTP MCU Copyright© 2014 by HOLTEK SEMICONDUCTOR INC. The information appearing in this Data Sheet is believed to be accurate at the time of publication. However, Holtek assumes no responsibility arising from the use of the specifications described. The applications mentioned herein are used solely for the purpose of illustration and Holtek makes no warranty or representation that such applications will be suitable without further modification, nor recommends the use of its products for application that may present a risk to human life due to malfunction or otherwise. Holtek's products are not authorized for use as critical components in life support devices or systems. Holtek reserves the right to alter its products without prior notification. For the most up-to-date information, please visit our web site at http://www.holtek.com.tw. Rev. 1.10 83 August 01, 2014