TrueSecureTM GTM-5110Cxx Series Embedded Fingerprint Module Revision: V1.10 Date: ���������������� October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module Table of Contents 1 Features.................................................................................................................... 3 2 Applications ............................................................................................................ 3 4 Block Diagram.......................................................................................................... 4 5 General Description................................................................................................. 4 6 Pin Description........................................................................................................ 5 7 Electrical Specifications......................................................................................... 5 8 Other Specifications................................................................................................ 6 9 Functional Description............................................................................................ 6 Hardware Description............................................................................................................. 6 Communication Protocol......................................................................................................... 7 Universal Asynchronous Receiver/Transmitter – UART.................................................................... 7 Checksum Generation....................................................................................................................... 7 Packet Types..................................................................................................................................... 8 Command Listing............................................................................................................................... 9 Command Description Details......................................................................................................... 10 Error Codes..................................................................................................................................... 26 Capturing a Fingerprint Image.............................................................................................. 27 Identifying and Verifying a Fingerprint Image....................................................................... 27 10 Application Circuit............................................................................................... 28 11 Mechanical Specifications.................................................................................. 29 Rev. 1.10 2 of 30 October 14, 2014 Table of Contents 3 Selection Table......................................................................................................... 3 GTM-5110Cxx Series Embedded Fingerprint Module 1 Features ▆▆ ▆▆ ▆▆ ▆▆ ▆▆ ▆▆ ▆▆ ▆▆ ▆▆ 2 Applications ▆▆ ▆▆ ▆▆ ▆▆ 3 Features ▆▆ Single chip fingerprint recognition module Complete integrated algorithms for learn, login and erase functions Advanced optical technology High accuracy and high recognition speed Ultra-thin optical sensor 1:1 verification and 1:N identification Downloadable sensor fingerprint image Fingerprint templates can be read/written to module UART communication protocol for interfacing to external master MCU Easy fingerprint recognition product integration Notebook computer login Household security products Vehicle entry systems Biometric identification products Selection Table The range of devices shown in the selection table are similar in function, but differ mainly in their fingerprint storage capacity, mechanical construction, pixel count, rotation range etc. Part No. GTM-5110C2 GTM-5110C21 GTM-5110C3 GTM-5110C31 GTM-5110C5 GTM-5110C51 Rev. 1.10 Effective Resolution Area (mm2) (DPI) Image Pixels No. of Rotation Fingerprints (Degree) Template Byte Size Compare Dimension (mm3) Time - sec (W×D×H) 14×12.5 450 240×216 20 360 506 1.5 14×12.5 450 258×202 200 360 498 1 14×12.5 450 258×202 2000 360 498 1.5 3 of 30 17×37×7.74 21×36.1×7.74 17×37×7.74 21×36.1×7.74 17×37×7.74 21×36.1×7.74 October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module 4 Block Diagram The following shows a simplified version of the internal functions of the fingerprint module. Holtek HT32F2755 ARM M3 Core TX pin RX pin UART Interface Fingerprint Recognition Algorithm 5 General Description Fingerprint recognition technology provides a secure and accurate means of biometric identification. This range of device from offers users a quick and easy implementation method for biometric fingerprint recognition. The integration of an optical fingerprint sensor, Holtek 32-bit ARM core microcontroller and fully programmed algorithm into a single module together combine to form complete fingerprint recognition module. A number of fingerprint images or templates are stored within the devices internal Flash Memory and therefore retain storage when power is removed. The storage capacity varies according to the module type selected. With easy commands such as learn, login and erase, this range of device offer a convenient and easy to use solution for users wishing to implement fingerprint biometric security into their products. Rev. 1.10 4 of 30 October 14, 2014 Block Diagram Fingerprint Sensor GTM-5110Cxx Series Embedded Fingerprint Module 6 Pin Description The fingerprint modules have a very simple 4 pin structure with two pins for power and the remaining two for the UART communication. Pin No. 1 TX UART transmit pin 2 RX UART receive pin 3 GND Ground pin 4 VCC Power Supply Electrical Specifications Symbol Rev. 1.10 Function Pin Description 7 Pin Name Parameter Test Conditions Min Typ Max Units — 3.3 5.0 6.0 V — — 130 mA — — 0.8 V 0.8 VDD — — V — 0.4 V VDD Operating Voltage IDD Operating Current VIL RX input low voltage — VIH RX input high voltage — VOL TX input low voltage IOL = TBD — VOH TX input high voltage IOH = TBD 2.9 — — V IOL TX port sink current — 8 TBD TBD mA tSST System start up time — 500 — — ms RRVDD VDD rise rate — TBD — — V/ms BRPON Power-on Baud Rate — TBD 9600 TBD Hz No output pin load 5 of 30 October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module 8 Other Specifications Item Communication Interface UART Matching Mode 1:1, 1:N False Acceptance Rate – FAR < 0.001% False Rejection Rate – FRR < 0.1% Enrollment time < 3 sec (3 fingerprints) Operating Environment Temp -20°C ~ +60°C Operating Environment Humidity -20% ~ 80% Storage Environment Temp -20°C ~ +60°C Storage Environment Humidity 10% ~ 80% Other Specifications 9 Value Functional Description These fingerprint recognition modules, by integrating a fingerprint sensor, 32-bit Holtek microcontroller and complete algorithms contain all the necessary hardware and software for full implementation of fingerprint recognition functions. The user has only to communicate with the fingerprint module using its UART interface to communicate with the internal hardware and to implement functions such as learn, erase and login. This set of devices communicates to the outside world via its internal UART interface. This would normally be communication with an external UART interface equipped microcontroller. Hardware Description It is through an internal UART interface that the fingerprint module communicates with external microcontrollers. There are two pins associated with the UART, one for data transmission, the TX pin, and one for data reception, the RX pin. Both TX and RX pins have CMOS structures. At power on the internal hardware will require a specific amount of time to initialise before commands can be received over its UART interface from external hardware. This time is specified in the electrical specifications. No command can be issued to the fingerprint module during this period. Note also that a specific minimum power supply rise time is also required to ensure a proper power on and initialise sequence. Rev. 1.10 6 of 30 October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module Communication Protocol The fingerprint modules communicate with external hardware such as microcontrollers using a fully internal UART interface. UART, means Universally Asynchronous Receiver Transmitter, and is a very popular and easy to use communication method. Universal Asynchronous Receiver/Transmitter – UART Using this UART interface, an external microcontroller can communicate with the fingerprint module by sending a fixed range of commands transmitted in packets. Within each UART frame the data is preceded by a zero start bit and terminated by a high stop bit. There is no parity bit in the UART frame. Low Start Bit 0 High Stop Bit D1 D0 D2 D3 D4 D5 D6 D7 1 8 Data Bits UART Frame – 10 Bits The fingerprint module UART interface contains its own internal Baud Rate generator. When the device is first powered on this Baud Rate will be set to a default value of 9600 Hz. as specified in the electrical characteristics. This Baud Rate can be changed to a different value using an externally requested command sent over the UART interface to match the communication rate of the master MCU. As the data communication is asynchronous the transmitter and receiver do not share a common clock. Checksum Generation For each transmission, whether it be command, acknowledge or data, at the end of each data packet, a checksum is generated. This is calculated by a simple addition of all the transmitted bytes as follows: Checksum = OFFSET[0]+…+OFFSET[4+N-1] Rev. 1.10 7 of 30 October 14, 2014 Functional Description It is through the UART interface that the fingerprint module communicates with external hardware. There are two pins associated with the UART, one for data transmission, the TX pin, and one for data reception, the RX pin. The UART interface sends a byte serially over time, with an indication of start and end of a byte, in the form of start and stop bits, at a particular speed setup by the Baud Rate. After power on the Baud Rate will default to a fixed value but can be later modified using a UART command. GTM-5110Cxx Series Embedded Fingerprint Module Packet Types There are three packet types which are command, acknowledge and data. Multiple-bytes are ordered using Little Endian. This is to say that the least significant bytes are stored in the lowest addresses. Offset Content Size Description 0x55 BYTE Command start code1 1 0xAA BYTE Command start code2 2 Device ID WORD Device ID: default is 0x0001, always fixed 4 Parameter DWORD Input parameter 8 Command WORD Command code 10 Check Sum WORD Check Sum (byte addition) OFFSET[0]+…+OFFSET[9]=Check Sum Command Packet Description Offset Content Size Description 0 0x55 BYTE Response start code1 1 0xAA BYTE Response start code2 2 Device ID WORD Device ID: default is 0x0001, always fixed 4 Parameter DWORD Response == 0x30: (ACK) Output Parameter Response == 0x31: (NACK) Error code 8 Response WORD 0x30: Acknowledge (ACK). 0x31: Non-acknowledge (NACK). 10 Check Sum WORD Check Sum (byte addition) OFFSET[0]+…+OFFSET[9]=Check Sum Acknowledge Packet Description Offset Content Size Description 0 0x5A BYTE Data start code1 1 0xA5 BYTE Data start code2 2 Device ID WORD Device ID: default is 0x0001, always fixed 4 Data N BYTES N bytes Data The size is pre-defined per protocol stage 4+N Check Sum WORD Check Sum (byte addition) OFFSET[0]+…+OFFSET[4+N-1]=Check Sum Data Packet Description Rev. 1.10 8 of 30 October 14, 2014 Functional Description 0 GTM-5110Cxx Series Embedded Fingerprint Module Command Listing All communication between external hardware, which in most cases will be a microcontroller, and the fingerprint module is executed via the UART interface using a fixed set of commands. The full set of commands along with their details are set out in the following chapters. The following table provides a summary of all available commands. Number HEX Description Open Initialisation 02 Close Termination 03 UsbInternalCheck Check if the connected USB device is valid 04 ChangeBaudrate Change UART baud rate 05 SetIAPMode Enter IAP Mode In this mode, FW Upgrade is available 12 CmosLed Control CMOS LED 20 GetEnrollCount Get enrolled fingerprint count 21 CheckEnrolled Check whether the specified ID is already enrolled 22 EnrollStart Start an enrollment 23 Enroll1 Make 1st template for an enrollment 24 Enroll2 Make 2nd template for an enrollment 25 Enroll3 Make 3rd template for an enrollment, merge three templates into one template, save merged template to the database 26 IsPressFinger Check if a finger is placed on the sensor 40 DeleteID Delete the fingerprint with the specified ID 41 DeleteAll Delete all fingerprints from the database 50 Verify 1:1 Verification of the capture fingerprint image with the specified ID 51 Identify 1:N Identification of the capture fingerprint image with the database 52 VerifyTemplate 1:1 Verification of a fingerprint template with the specified ID 53 IdentifyTemplate 1:N Identification of a fingerprint template with the database 60 CaptureFinger Capture a fingerprint image(256x256) from the sensor 61 MakeTemplate Make template for transmission 62 GetImage Download the captured fingerprint image(256x256) 63 GetRawImage Capture & Download raw fingerprint image(320x240) 70 GetTemplate Download the template of the specified ID 71 SetTemplate Upload the template of the specified ID 72 GetDatabaseStart Start database download – obsolete 73 GetDatabaseEnd End database download, – obsolete 80 UpgradeFirmware Firmware Upgrade 81 UpgradeISOCDImage Not supported 30 Ack Acknowledge. 31 Nack Non-acknowledge. 9 of 30 October 14, 2014 Functional Description Rev. 1.10 Alias 01 GTM-5110Cxx Series Embedded Fingerprint Module Command Description Details All of the GTM fingerprint modules share a common set of commands. However within a subset of commands there are certain parameters that must also be transmitted., such as fingerprint ID and certain data for that particular module. The value of these parameters differ according to specific part numbers. The following table shows this command subset and the relevant parameters that need to be defined within these commands. CheckEnrolled GTM Device Parameter Type ID 5110C2/C21 0~19 5110C3/C31 0~199 5110C5/C51 0~1999 EnrollStart ID 0~19 0~199 0~1999 DeleteID ID 0~19 0~199 0~1999 Verify ID 0~19 0~199 0~1999 ID 0~19 0~199 0~1999 VerifyTemplate Data 506 498 498 IdentifyTemplate Data 506 498 498 MakeTemplate Data 506 498 498 GetImage Data 240×216 258×202 258×202 GetRawImage Data 240×216 160×120 160×120 ID 0~19 0~199 0~1999 Data 506 498 498 ID 0~19 0~199 0~1999 Data 506 498 498 GetTemplate SetTemplate The following describes each command in detail. Initialization (Open) The Open command is used for module initialization and to obtain the module static information. Field Sample Description FirmwareVersion FirmwareVersion: 20120225 Firmware version IsoAreaMaxSize IsoAreaMaxSize: 0KB Maximum ISO CD image size DeviceSerialNumber DeviceSN: EF15EF4016C66250-888F1A41 Unique device serial number Description of devinfo structure If the Module’s Serial Number is zero, it must be noted that the device may not operate correctly. Rev. 1.10 10 of 30 October 14, 2014 Functional Description Command Name GTM-5110Cxx Series Embedded Fingerprint Module Host Device Host Command Packet Command = Open Parameter = Zero: no request for extra information Nonzero: requires extra information If the host requests extra information then provide the following: Module Data Packet Data = typedefstruct_devinfo { DWORD FirmwareVersion; DWORD IsoAreaMaxSize; BYTEDeviceSerialNumber[16]; } devinfo; Termination (Close) The Close command results in no action. Host Device Host Command Packet Command = Close Rev. 1.10 11 of 30 Module Response Packet Response = Ack October 14, 2014 Functional Description Module Response Packet Response = Ack GTM-5110Cxx Series Embedded Fingerprint Module Fast device search (UsbInternalCheck) Operation is similar to a removable CD drive. However if there is another removable CD in the system, it may take a longer time to achieve a connection. The UsbInternalCheck command is used to overcome this problem by fast searching for the device. Host Device Functional Description Host Command Packet Command = UsbInternalCheck Module Response Packet Response = Ack Parameter = 0x55 CMOS LED control (CmosLed) The CMOS (Sensor) LED default condition is an OFF condition. However, note that during the boot process, the LED will flash once, providing an indication that the LED is working. So it is important to send an LED ON command before any data capture actions are executed. Host Device Host Command Packet Command = CmosLed Parameter = Zero: Off LED Nonzero: On LED Rev. 1.10 12 of 30 Module Response Packet Response = Ack October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module Changing the UART baud rate (ChangeBaudrate) The UART baud rate can be changed using this command during normal running. After power on the module will be initialised to a 9600 bps UART baud rate. Host Device Functional Description Host Command Packet Command = ChangeBaudrate Parameter = baud rate (9600~115200) Module Response Packet Response = Ack: Response = Nack: Error NACK_INVALID_PARAM Obtain enrolled fingerprint count (GetEnrollCount) Host Device Host Command Packet Command = GetEnrollCount Rev. 1.10 13 of 30 Module Response Packet Response = Ack Parameter = Enrolled Fingerprint Count October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module Check enrollment status (CheckEnrolled) Host Device Host Command Packet Command = CheckEnrolled Parameter = ID(0~1999) Module Response Packet Response = Ack: This ID is enrolled Response = Nack: Error NACK_INVALID_POS NACK_IS_NOT_USED Start an enrollment process (EnrollStart) Host Device Host Command Packet Command = EnrollStart Parameter = ID(0~1999) If ID == -1, then “Enrollment without saving” will be stated. Rev. 1.10 14 of 30 Module Response Packet Response = Ack: OK Response = Nack: Error NACK_DB_IS_FULL NACK_INVALID_POS NACK_IS_ALREADY_USED October 14, 2014 Functional Description GTM-5110Cxx Series Embedded Fingerprint Module Generate the first enrollment template (Enroll1) Host Device Host Command Packet Command = Enroll1 Functional Description Module Response Packet Response = Ack: OK Response = Nack: Error NACK_ENROLL_FAILED NACK_BAD_FINGER Duplicated ID(0~1999) Generate the second enrollment template (Enroll2) Host Device Host Command Packet Command = Enroll2 Module Response Packet Response = Ack: OK Response = Nack: Error NACK_ENROLL_FAILED NACK_BAD_FINGER Duplicated ID(0~1999) Rev. 1.10 15 of 30 October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module Generate the third enrollment template and then merge the three templates (Enroll3) To implement a full fingerprint enrollment process, the host must send out the previous four commands. More details regarding this is provided in a different section. Host Device Functional Description Host Command Packet Command = Enroll3 Module Response Packet Response = Ack: OK Response = Nack: Error NACK_ENROLL_FAILED NACK_BAD_FINGER Duplicated ID(0~1999) It should be noted that if EnrollStart was called with ID = -1, this will result in the enrolled template not being saved. Here it will be transferred to the host, as shown below. Rev. 1.10 16 of 30 Module Response Packet Data = enrolled template (498 bytes) October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module Check the finger press status (IsPressFinger) During the enrollment process, this command is used during the time when the host is waiting for the finger to be removed. Host Device Module Response Packet Response = Ack: Parameter = Zero: finger is pressed Parameter = nonzero: finger is not pressed Delete a single fingerprint (DeleteID) Host Device Host Command Packet Command = DeleteID Parameter = ID(0~1999) Rev. 1.10 17 of 30 Module Response Packet Response = Ack: OK Response = Nack: Error NACK_INVALID_POS October 14, 2014 Functional Description Host Command Packet Command = IsPressFinger GTM-5110Cxx Series Embedded Fingerprint Module Delete all fingerprints (DeleteAll) Host Device Host Command Packet Command = DeleteAll Functional Description Module Response Packet Response = Ack: OK Response = Nack: Error NACK_DB_IS_EMPTY 1:1 Verification (Verify) Host Device Host Command Packet Command = Verify Parameter = ID(0~1999) Rev. 1.10 18 of 30 Module Response Packet Response = Ack: OK Response = Nack: Error NACK_INVALID_POS NACK_IS_NOT_USED NACK_VERIFY_FAILED October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module 1:N Identification (Identify) Host Device Host Command Packet Command = Identify 1:1 Template Verification (VerifyTemplate) Host Device Host Command Packet Command = VerifyTemplate Parameter = ID(0~1999) Host Command Packet Data = a template (498 bytes) Rev. 1.10 Module Response Packet Response = Ack: OK Response = Nack: Error NACK_INVALID_POS NACK_IS_NOT_USED 19 of 30 Module Response Packet Response = Ack: OK Response = Nack: Error NACK_COMM_ERR NACK_VERIFY_FAILED October 14, 2014 Functional Description Module Response Packet Response = Ack: OK Parameter = 0~1999: identified ID Response = Nack: Error NACK_DB_IS_EMPTY NACK_IDENTIFY_FAILED GTM-5110Cxx Series Embedded Fingerprint Module 1:N Template Identification (IdentifyTemplate) Host Device Host Command Packet Command = IdentifyTemplate Host Command Packet Data = a template (498 bytes) Rev. 1.10 Functional Description Module Response Packet Response = Ack: OK Response = Nack: Error NACK_DB_IS_EMPTY 20 of 30 Module Response Packet Response = Ack: OK Parameter = 0~1999: identified ID Response = Nack: Error NACK_COMM_ERR NACK_IDENTIFY_FAILED October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module Capture fingerprint (CaptureFinger) The raw fingerprint image data is captured from the sensor using this command. As the fingerprint algorithm is setup to process a 450dpi 256×256 image, the captured image is converted to a 256×256 image before algorithmic processing. If no finger is detected then the command will return a non-acknowledge. Host Device Module Response Packet Response = Ack: OK Response = Nack: Error NACK_FINGER_IS_NOT_PRESSED Generate a Template (MakeTemplate) This command is used to generate a template for transmission. Before sending this command a CaptureFinger command should have been previously sent. The template should not be used for registration. Host Device Host Command Packet Command = MakeTemplate Rev. 1.10 21 of 30 Module Response Packet Response = Ack: OK Response = Nack: Error NACK_BAD_FINGER Module Response Packet Data = made template (498 bytes) October 14, 2014 Functional Description Host Command Packet Command = CaptureFinger Parameter = Zero: not best image, but fast Nonzero: best image, but slow GTM-5110Cxx Series Embedded Fingerprint Module Obtain fingerprint image (GetImage) Host Device Host Command Packet Command = GetImage Module Response Packet Data = 258×202 image (52116 bytes) Obtain raw image (GetRawImage) Host Device Host Command Packet Command = GetRawImage Rev. 1.10 22 of 30 Capture raw image Module Response Packet Response = Ack: OK Module Response Packet Data = 160×120 QVGA image (19200 bytes) October 14, 2014 Functional Description Module Response Packet Response = Ack: OK GTM-5110Cxx Series Embedded Fingerprint Module Obtain template (GetTemplate) Host Device Host Command Packet Command = GetTemplate Parameter = ID(0~1999) Rev. 1.10 23 of 30 Functional Description Module Response Packet Response = Ack: OK Response = Nack: Error NACK_INVALID_POS NACK_IS_NOT_USED Module Response Packet Data = a template (498 bytes) October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module Set template (SetTemplate) Host Device Host Command Packet Command = SetTemplate Parameter = ID(0~1999) (If Parameter’s HIWORD is non-zero, fingerprint duplication check will not be performed.) Host Command Packet Data = a template (498 bytes) Functional Description Module Response Packet Response = Ack: OK Response = Nack: Error NACK_INVALID_POS Module Response Packet Response = Ack: OK Response = Nack: Error NACK_COMM_ERR NACK_DEV_ERR Duplicated ID(0~1999) Start a database download – obsolete command (GetDatabaseStart) This command is now obsolete, no longer required and therefore results in no action. It was formerly used for RS232 interface communication purposes and for historical reasons remains. Host Device Host Command Packet Command = GetDatabaseStart Rev. 1.10 24 of 30 Module Response Packet Response = Ack October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module End database download – obsolete command (GetDatabaseEnd) This command is now obsolete, no longer required and therefore results in no action. It was formerly used for RS232 interface communication purposes and for historical reasons remains. Host Device Functional Description Host Command Packet Command = GetDatabaseEnd Module Response Packet Response = Ack Upgrade Firmware (UpgradeFirmware) Not supported Upgrade the ISO CD Image (UpgradeISOCDImage) Not supported Set IAP Mode (SetIAPMode) This command is used to make the module enter into the IAP Mode. When in the IAP mode a FW upgrade can be executed. Host Device Host Command Packet Command = SetIAPMode Rev. 1.10 25 of 30 Module Response Packet Response = Ack October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module Error Codes When the response to any command is a Non-acknowledge, then an error code will be generated as shown in the accompanying table. NACK Parameter Description NACK_TIMEOUT 0x1001 Obsolete, capture timeout NACK_INVALID_BAUDRATE 0x1002 Obsolete, Invalid serial baud rate NACK_INVALID_POS 0x1003 The specified ID is not between 0~19 NACK_IS_NOT_USED 0x1004 The specified ID is not used NACK_IS_ALREADY_USED 0x1005 The specified ID is already used NACK_COMM_ERR 0x1006 Communication Error NACK_VERIFY_FAILED 0x1007 1:1 Verification Failure NACK_IDENTIFY_FAILED 0x1008 1:N Identification Failure NACK_DB_IS_FULL 0x1009 The database is full NACK_DB_IS_EMPTY 0x100A The database is empty NACK_TURN_ERR 0x100B Obsolete, Invalid order of the enrollment (The order was not as: EnrollStart → Enroll1 → Enroll2 → Enroll3) NACK_BAD_FINGER 0x100C Too bad fingerprint NACK_ENROLL_FAILED 0x100D Enrollment Failure NACK_IS_NOT_SUPPORTED 0x100E The specified command is not supported NACK_DEV_ERR 0x100F Device Error, especially if Crypto-Chip is trouble NACK_CAPTURE_CANCELED 0x1010 Obsolete, The capturing is canceled NACK_INVALID_PARAM 0x1011 Invalid parameter NACK_FINGER_IS_NOT_PRESSED 0x1012 Finger is not pressed Duplicated ID 0 – 19 There is duplicated fingerprint (while enrollment or setting template), This error describes just duplicated ID 26 of 30 October 14, 2014 Functional Description Rev. 1.10 Value GTM-5110Cxx Series Embedded Fingerprint Module Capturing a Fingerprint Image A fingerprint image can be read and stored by transmitting a series of commands to the fingerprint module as follows. IsPressFinger is used to check whether a finger has been placed on the sensor. This function is used during enrollment. GetRawImage is used to capture a raw live image. It will not check if a finger has been placed on the sensor. This function is used for debug or calibration. Identifying and Verifying a Fingerprint Image After capturing a fingerprint image it then has to be identified and verified as follows. Identify and IdentifyTemplate perform a 1: N matching operation. Verify and VerifyTemplate perform a 1: 1 matching operation. Before the image-related matching functions, Identify and Verify, are called, the host must first call CaptureFinger. Rev. 1.10 27 of 30 October 14, 2014 Functional Description CaptureFinger is used to capture the fingerprint image. If a finger has not been placed on the sensor, it will return an error. If the function is successful, the device’s internal RAM will store the data as a valid fingerprint image, ready for use by subsequent commands. If the host issues other command, the fingerprint image will be used and destroyed. GTM-5110Cxx Series Embedded Fingerprint Module 10 Application Circuit As the GTM series of Fingerprint Modules are fully integrated requiring no external components for their operation, the addition of an external MCU, communicating via the UART interface is all that is required to implement a fingerprint recognition system. GTM-5110Cxx F�inge�p�int Module Application Circuit VDD TX Maste� MCU RX VSS Rev. 1.10 28 of 30 October 14, 2014 GTM-5110Cxx Series Embedded Fingerprint Module 12.90 17 16.68 Mechanical Specifications 6.82 0.10 Pin1 = TX Pin2 = RX Pin3 = GND Pin4 = VCC 3.3V~6V 6 2.16 16.90 5 21.13 37 0.75 1.46 9.27 3.70 October 14, 2014 29 of 30 Rev. 1.10 Mechanical Specifications 11 GTM-5110Cxx Series Embedded Fingerprint Module Mechanical Specifications Copyright© 2014 by HOLTEK SEMICONDUCTOR INC. The information appearing in this Data Sheet is believed to be accurate at the time of publication. However, Holtek assumes no responsibility arising from the use of the specifications described. The applications mentioned herein are used solely for the purpose of illustration and Holtek makes no warranty or representation that such applications will be suitable without further modification, nor recommends the use of its products for application that may present a risk to human life due to malfunction or otherwise. Holtek's products are not authorized for use as critical components in life support devices or systems. Holtek reserves the right to alter its products without prior notification. For the most up-to-date information, please visit our web site at http://www. holtek.com.tw. Note that Holtek’s fingerprint recognition products have been designed in conjunction with Gingy Technology. Rev. 1.10 30 of 30 October 14, 2014