TOSHIBA TC74VHC4020FT

TC74VHC4020F/FT/FK
TOSHIBA CMOS Digital Integrated Circuit
Silicon Monolithic
TC74VHC4020F,TC74VHC4020FT,TC74VHC4020FK
14-Stage Ripple Carry Binary Counter
The TC74VHC4020 is an advanced high speed CMOS
14-STAGE BINARY COUNTER/DIVIDER fabricated with silicon
gate C2MOS technology.
It achieves the high speed operation similar to equivalent
Bipolar Schottky TTL while maintaining the CMOS low power
dissipation.
Setting CLR to high resets the counter to low.
A negative transition on the CK input brings one increment
into the counter.
This counter provides all divided output stages, and at Q12, a
1/4096 divided frequency will be output.
An input protection circuit ensures that 0 to 5.5 V can be
applied to the input pins without regard to the supply voltage.
This device can be used to interface 5 V to 3 V systems and two
supply systems such as battery back up. This circuit prevents
device destruction due to mismatched supply and input voltages.
TC74VHC4020F
TC74VHC4020FT
Features
•
High speed: fmax = 210 MHz (typ.) at VCC = 5 V
•
Low power dissipation: ICC = 4 μA (max) at Ta = 25°C
•
High noise immunity: VNIH = VNIL = 28% VCC (min)
•
•
Power down protection is provided on all inputs.
Balanced propagation delays: tpLH ∼
− tpHL
•
Wide operating voltage range: VCC (opr) = 2 V to 5.5 V
•
Low noise: VOLP = 1.5 V (max)
•
Pin and function compatible with 74HC4020
TC74VHC4020FK
Weight
SOP16-P-300-1.27A
TSSOP16-P-0044-0.65A
VSSOP16-P-0030-0.50
1
: 0.18 g (typ.)
: 0.06 g (typ.)
: 0.02 g (typ.)
2007-10-01
TC74VHC4020F/FT/FK
Pin Assignment
IEC Logic Symbol
RCTR 14
Q12
1
16
VCC
Q13
2
15
Q11
Q14
3
14
Q10
Q6
4
13
Q8
Q5
5
12
Q9
Q7
6
11
CLR
Q4
7
10
CK
GND
8
9
Q1
CLR
(11)
CT = 0
0
3
4
(9)
(7)
(5)
(4)
(6)
(13)
CK
(10)
+
CT
(12)
(14)
(15)
(1)
(2)
13
(3)
Q1
Q4
Q5
Q6
Q7
Q8
Q9
Q10
Q11
Q12
Q13
Q14
(top view)
Truth Table
CK
CLR
Output State
X
H
All Outputs = “L”
L
No Change
L
Advance to Next State
X: Don’t care
2
2007-10-01
TC74VHC4020F/FT/FK
System Diagram
Q1
Q4
9
D
CK
CLR
10
Q5
7
D
D
D
Q7
Q6
5
6
4
D
D
D
CK Q
CK Q
CK Q
CK Q
CK Q
CK Q
CK Q
R
R
R
R
R
R
R
11
R
R
R
R
R
R
R
Q CK
Q CK
Q CK
Q CK
Q CK
Q CK
Q CK
D
D
D
D
D
D
D
3
2
1
Q14
Q13
Q12
15
14
Q11
Q10
12
13
Q9
Q8
Absolute Maximum Ratings (Note)
Characteristics
Symbol
Rating
Unit
Supply voltage range
VCC
−0.5 to 7.0
V
DC input voltage
VIN
−0.5 to 7.0
V
VOUT
−0.5 to VCC + 0.5
V
Input diode current
IIK
−20
mA
Output diode current
IOK
±20
mA
DC output current
IOUT
±25
mA
DC VCC/ground current
ICC
±100
mA
Power dissipation
PD
180
mW
Storage temperature
Tstg
−65 to 150
°C
DC output voltage
Note:
Exceeding any of the absolute maximum ratings, even briefly, lead to deterioration in IC performance or
even destruction.
Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the
significant change in temperature, etc.) may cause this product to decrease in the reliability significantly
even if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute
maximum ratings and the operating ranges.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
3
2007-10-01
TC74VHC4020F/FT/FK
Operating Ranges (Note)
Characteristics
Symbol
Rating
Unit
Supply voltage
VCC
2.0 to 5.5
V
Input voltage
VIN
0 to 5.5
V
VOUT
0 to VCC
V
−40 to 85
°C
Output voltage
Operating temperature
Topr
Input rise and fall time
Note:
0 to 100 (VCC = 3.3 ± 0.3 V)
dt/dv
ns/V
0 to 20 (VCC = 5 ± 0.5 V)
The operating ranges must be maintained to ensure the normal operation of the device.
Unused inputs must be tied to either VCC or GND.
Electrical Characteristics
DC Characteristics
Characteristics
Test Condition
Symbol
VCC (V)
Min
2.0
1.50
3.0 to
5.5
VCC ×
0.7
―
―
―
3.0 to
5.5
―
―
VCC ×
0.3
―
VCC ×
0.3
2.0
1.9
2.0
―
1.9
―
3.0
2.9
3.0
―
2.9
―
4.5
4.4
4.5
―
4.4
―
IOH = −4 mA
3.0
2.58
―
―
2.48
―
IOH = −8 mA
4.5
3.94
―
―
3.80
―
2.0
―
0.0
0.1
―
0.1
IOL = 50 μA
3.0
―
0.0
0.1
―
0.1
4.5
―
0.0
0.1
―
0.1
IOL = 4 mA
3.0
―
―
0.36
―
0.44
IOL = 8 mA
4.5
―
―
0.36
―
0.44
High-level input
voltage
VIH
―
Low-level input
voltage
VIL
―
High-level output
voltage
Low-level output
voltage
2.0
VOH
VOL
VIN
= VIH or
VIL
VIN
= VIH or
VIL
Ta =
−40 to 85°C
Ta = 25°C
IOH = −50 μA
Typ.
Max
―
―
―
0.50
Min
1.50
VCC ×
0.7
―
Unit
Max
―
―
V
0.50
V
V
V
Input leakage
current
IIN
VIN = 5.5 V or GND
0 to 5.5
―
―
±0.1
―
±1.0
μA
Quiescent supply
current
ICC
VIN = VCC or GND
5.5
―
―
4.0
―
40.0
μA
Ta =
−40 to
85°C
Unit
Timing Requirements (input: tr = tf = 3 ns)
Characteristics
Symbol
Minimum pulse width
tw (L)
( CK )
tw (H)
Minimum pulse width
(CLR)
Minimum removal time
Test Condition
―
tw (H)
―
trem
―
4
Ta = 25°C
VCC (V)
Typ.
Limit
Limit
3.3 ± 0.3
―
5.0
5.0
5.0 ± 0.5
―
5.0
5.0
3.3 ± 0.3
―
5.0
5.0
5.0 ± 0.5
―
5.0
5.0
3.3 ± 0.3
―
5.0
5.0
5.0 ± 0.5
―
5.0
5.0
ns
ns
ns
2007-10-01
TC74VHC4020F/FT/FK
AC Characteristics (input: tr = tf = 3 ns)
Characteristics
Test Condition
Symbol
VCC (V)
Propagation delay
time
tpLH
( CK -Q1)
tpHL
Propagation delay
time
Typ.
Max
Min
Max
15
―
7.5
11.9
―
14.0
50
―
10.0
15.4
―
17.5
15
―
4.8
7.3
―
8.5
50
―
6.3
9.3
―
10.5
3.3 ± 0.3
50
―
2.4
4.4
―
5.0
5.0 ± 0.5
50
―
1.6
3.1
―
3.5
15
―
8.3
12.8
―
15.0
50
―
10.8
16.3
―
18.5
15
―
5.6
8.6
―
10.0
50
―
7.1
10.6
―
12.0
15
75
140
―
75
―
50
55
80
―
50
―
15
150
210
―
125
―
50
95
125
―
80
―
―
4
10
―
10
pF
―
21
―
―
―
pF
5.0 ± 0.5
(Qn-Qn + 1)
Propagation delay
time
Min
―
―
3.3 ± 0.3
―
tpHL
(CLR-Q)
5.0 ± 0.5
3.3 ± 0.3
Maximum clock
frequency
―
fmax
5.0 ± 0.5
Input capacitance
CIN
Power dissipation
capacitance
CPD
Unit
CL (pF)
3.3 ± 0.3
Δtpd
Ta =
−40 to 85°C
Ta = 25°C
―
(Note)
ns
ns
ns
MHz
Note: CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating
current consumption without load.
Average operating current can be obtained by the equation:
ICC (opr) = CPD·VCC·fIN + ICC
Noise Characteristics (input: tr = tf = 3 ns)
Characteristics
Quiet output maximum dynamic
Test Condition
Symbol
Ta = 25°C
VCC (V)
Typ.
Limit
Unit
VOLP
CL = 50 pF
5.0
1.2
1.5
V
VOLV
CL = 50 pF
5.0
−1.2
−1.5
V
Minimum high level dynamic input
voltage
VIHD
CL = 50 pF
5.0
―
3.5
V
Maximum low level dynamic input
voltage
VILD
CL = 50 pF
5.0
―
1.5
V
VOL
Quiet output minimum dynamic
VOL
5
2007-10-01
TC74VHC4020F/FT/FK
Input Equivalent Circuit
INPUT
6
2007-10-01
TC74VHC4020F/FT/FK
Package Dimensions
Weight: 0.18 g (typ.)
7
2007-10-01
TC74VHC4020F/FT/FK
Package Dimensions
Weight: 0.06 g (typ.)
8
2007-10-01
TC74VHC4020F/FT/FK
Package Dimensions
Weight: 0.02 g (typ.)
9
2007-10-01
TC74VHC4020F/FT/FK
RESTRICTIONS ON PRODUCT USE
20070701-EN GENERAL
• The information contained herein is subject to change without notice.
• TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc.
• The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in his
document shall be made at the customer’s own risk.
• The products described in this document shall not be used or embedded to any downstream products of which
manufacture, use and/or sale are prohibited under any applicable laws and regulations.
• The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which
may result from its use. No license is granted by implication or otherwise under any patents or other rights of
TOSHIBA or the third parties.
• Please contact your sales representative for product-by-product details in this document regarding RoHS
compatibility. Please use these products in this document in compliance with all applicable laws and regulations
that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses
occurring as a result of noncompliance with applicable laws and regulations.
10