OVER VIEW
The C9536/H9958 series are optical power meters designed to
measure absolute optical power of UV light (mW/cm2). These optical
power meters have a flat spectral response over a wide UV wavelength region, and are capable of measuring the optical power independent of the spectral emission distribution of a light source to be
measured. Unlike commonly available UV power meters, optical power of various UV light sources can be easily measured with just one
unit of this power meter, without having correct each wavelength of
emitted light. A combination of the C9536-02 and H9958-02 is suitable for measuring the optical power of high output UV-LED.
Also, we recommend a combination of the C9536-01 and H9958 as a
power meter to measure the optical power of light sources for photocatalysis.
FEATURES
Left: Controller C9536-01
Right: Sensor Head H9958/-01
Left: Controller C9536-02
Right: Sensor Head H9958-02
APPLICATIONS
●Traceable to National Standard in Japan and a Certificate of
Calibration is Appended
●Flat Spectral Response Characteristics Over a Wide UV Region
●High Sensitivity (detectable down to 1 µW/cm2)
●Compatible with high output UV-LED
●Ideal for Monitoring / Controlling Light Source Power for Photocatalyst
Monitoring, Measurement and Control of:
●Black Light
●UV LED
●Ultraviolet Rays (UV-A)
●Mercury-Xenon Lamp
●High Pressure Mercury-Xenon Lamp
●Deuterium Lamp
SPECIFICATIONS
CONTROLLER: C9536-01/C9536-02
Parameter
Continuous
Measurement
Mode
Integration
One Shot (C9536-01 only)
Peak Hold (C9536-02 only)
External Interface
Power Requirement
Dimensions (W × H × D)
Operating Ambient Temperature / Humidity
Storage Temperature / Humidity
Weight
Description / Value
This mode makes continuous measurements at a sampling rate of 1 second.
This mode displays a result integrated over a certain period of time
(adjustable from 1 second to 5 minutes in 1 second steps).
This mode makes one measurement each time START switch is pressed.
This mode holds the peak values in continuous measurement.
RS-232C
Internal battery or AC adapter
75 mm × 110 mm × 20 mm
0 °C to +40 °C / Below 80 %
-20 °C to +50 °C / Below 80 %
Approx. 285 g
SENSOR HEAD: H9958 SERIES
Parameter
Controller and Sensor Head Combination
Type
Spectral Response
Effective Area
Measurement Range
Dimensions (W × H × D)
Operating Ambient Temperature / Humidity
Storage Temperature / Humidity
Weight
Description / Value
C9536-02
C9536-01
H9958
H9958-01
H9958-02
300 nm to 410 nm
310 nm to 380 nm
1 mm
10 mm
100 µW/cm2 to 10 W/cm2
1 µW/cm2 to 100 mW/cm2
55 mm × 75 mm × 18 mm
0 °C to +45 °C / Below 80 %
0 °C to +60 °C / Below 80 %
-20 °C to +50 °C / Below 80 %
-20 °C to +60 °C / Below 80 %
Approx. 195 g
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are
subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2011 Hamamatsu Photonics K.K.
UV POWER METER C9536, H9958 SERIES
Figure 1: Relative Spectral Response Characteristics of Detector (Typ.)
(H9958: 310 nm to 380 nm)
Figure 2: Relative Spectral Response Characteristics of Detector (Typ.)
(H9958-01/-02: 300 nm to 410 nm)
351 368
TPT B0026EC
100
100
BLACK LIGHT
H9958
H9958-01/-02
RELATIVE VALUE (%)
RELATIVE VALUE (%)
365 385
TPT B0040EB
80
BLACK LIGHT
60
40
80
UV LED
UV LED
60
40
20
20
0
200
250
300
350
400
450
0
200
500
250
300
350
400
450
500
WAVELENGTH (nm)
WAVELENGTH (nm)
Note: Slight response may occur at some wavelength over 500 nm.
Note: Slight response may occur at some wavelength over 500 nm.
Figure 3: Detector Sensitivity vs. Incident Light Angle (Typ.)
TPT B0028EC
RELATIVE VALUE (%)
100
80
COS θ
60
H9958-02
40
H9958/-01
20
0
-100
-80
-60
-40
-20
0
20
40
60
80
100
ANGLE (degree)
Figure 4: Dimensional Outline (Unit: mm)
●Sensor Head: H9958 Series
●Controller: C9536 Series
47
LCD
26
55
26
55
18
15
110
55
75
75
UV POWER METER
SELECT
0.5
EFFECTIVE
AREA 1
INPUT WINDOW
14
EFFECTIVE AREA 10
4-M3
THREDED HOLE
ENTER
START
STOP
POWER
75
20
2000
2000
ANALOG OUTPUT CONNECTOR
RS-232C
RS-232C CONNECTOR
SIDE VIEW
ANALOG OUT
DC IN
DC INLET
TPT A0042EB
SIDE VIEW
●Controller and Sensor Head Combination
FRONT VIEW
(H9958/-01)
FRONT VIEW
(H9958-02)
TPT A0041EB
HAMAMATSU PHOTONICS K.K.
Controller
C9536-01
C9536-02
Sensor Head
H9958, H9958-01
H9958-02
www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Electron Tube Division
314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P. O. Box 6910, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: [email protected]
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: [email protected]
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: [email protected]
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road Welwyn Garden City Hertfordshire AL7 1BW, United Kingdom, Telephone: 44-(0)1707-294888, Fax: 44(0)1707-325777 E-mail: [email protected]
North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: [email protected]
TPT 1026E01
Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741 E-mail: [email protected]