Details

Connectivity solutions for photovoltaic power systems
LC4®-AM – Cable Assemblies, Modular harnesses
LC4-AM 30
LC4-AM 31
LC4® photovoltaic connecting cables, with assembled connectors and integrated locking
LC4-AM 30: with plug and open end
LC4-AM 31: with socket and open end
1. Temperature range
-40 °C/+85 °C (IEC)
-40 °C/+90 °C (UL)
(+115 °C upper limit temperature)
halogen-free, UV-resistant
m-PC, V1 according to UL 94
CuNiSi, tin-plated
silicone
2. Materials
Insulating body
Contact pin/bush
Sealing (sockets only)
3. Mechanical data
≤ 20 N
Insertion force1
≥ 10 N
Withdrawal force1
Retaining force of locking latches2 ≥ 90 N
50
Mating cycles2
Mating with
photovoltaic connectors LC4
IP 68
Protection degree3
Connected conductor
Photovoltaic cable, double-insulated, technical data on request
Section alternatively
2.5 mm2 (AWG 14)
4.0 mm2 (AWG 12)
6.0 mm2 (AWG 10)
LC4-AM 30
LC4-AM 31
4. Electrical data (at Tamb 20 °C)
Contact resistance2
Rated current (IEC)2
X
1
2
3
4
≤ 1 mΩ
22 A at Tamb 85 °C, 2.5 mm2 (AWG 14)
30 A at Tamb 85 °C, 4.0 mm2 (AWG 12)
30 A at Tamb 85 °C, 6.0 mm2 (AWG 10)
Rated current (UL)2
35 A at Tamb 20 °C, 2,5/4,0/6,0 mm2
Rated voltage4
1000 V DC (IEC)/600 V DC (UL)
4
III (8 kV)
Overvoltage category
4
IIIa (IEC)/3 (UL) (CTI ≥ 225)
Material group
Creepage distance/clearance between
contact and touchable surfaces
24.6 mm
contact and cable outlet
22.8 mm
Insulation resistance
> 10 GΩ
measured with a polished steel gauge, nominal thickness 4.0 mm
measured with a proper counterpart
according to IEC 60529/DIN EN 60529
only in mated condition with a proper counterpart
IP X8 requirements under agreement between manufacturer and user
according to DIN EN 60664/IEC 60664 resp. according to ANSI/UL 746A
®
X
LC4-AM 30 IT
Designation
LC4-AM ...
www.lumberg.com
details upon request
*a marking + on LC4-AM ...-1
marking – on LC4-AM ...-2
05/2013