Surface Mount Fuses Surge Resistant > 461 Series TeleLink® Fuse 461 Series TeleLink® Fuse RoHS Description The Littelfuse 461 Series TeleLink® Surface Mount, Surge Resistant Fuse, offers over-current protection for a wide range of telecom applications without requiring a series resistor. When used in conjunction with a Littelfuse SIDACtor® Transient Voltage Suppressor (TVS) or a GreentubeTM Gas Plasma Arrestor, this combination provides a compliant solution for standards and recommendations such as GR-1089–Core, TIA-968-A, UL/ EN/IEC 60950, and ITU K.20 and K.21. The coordination requirement contained in GR-1089–Core, and ITU K.20/21 may require a series of impedance devices. Agency Approvals AGENCY Features AGENCY FILE NUMBER AMPERE RANGE E10480 .5A - 2A 29862 .5A - 2A Electrical Characteristics for Series % of Ampere Rating Opening Time 100% 4 hours, Minimum 250% 1 sec., Min.; 120 secs., Max. Maximum Temperature Rise Telecom Nano2® Fuse Temperature Reading 04611.25 < 82°C (180°F) 0461002. < 50°C (122°F) Higher Currents and PCB layout designs can affect this parameter. Readings are measured at rated current after temperature stabilizes. Additional Information • Surface mount surge resistant Slo-Blo® fuse networking equipment • 2A rating has improved • Meet UL 60950 3rd Edition temperature rise performance under 2.2A power cross requirements surge current testing when standard alone compared with 1.25A • Designed to allow rating compliance with Telcordia • Product is Halogen Free GR-1089-CORE and TIAand RoHS compliant and 968-A (formerly FCC Part compatible with lead68) Surge Specifications free solder and higher • Provide coordinated temperature profiles when protection with Littelfuse ordered with Standard ® SIDACtor Transient Voltage Suppressor (TVS)or Silver Plated Brass Caps a GreentubeTM Gas Plasma • Standard product is RoHS Compliant and compatible Arrestor, without series with lead-free solders and resistors higher temperature profiles • Designed to serve the requirements of a wide range of telecommunication and Applications • T1/E1/J1 and HDSL2/4 Datasheet Resources Samples • SLIC interface portion of Fiber to the Curb (FTTC) and Fiber to the Premises (FTTP) • Non-Fiber SLIC interface for Central Office (CO) locations and Remote Terminals (RT) • xDSL applications such as ADSL, ADSL2+, VDSL, and VDSL2+ • Ethernet 10/100/1000BaseT • POTS applications such as modems, answering machines, telephones, fax machines, and security systems • ISDN “U” interface • Baystation T1/E1/J1, T3 (DS3) trunk cards © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Application testing istostrongly Specifications are subject change recommended. without notice. Revised: 05/18/15 Surface Mount Fuses Surge Resistant > 461 Series TeleLink® Fuse Electrical Specifications by Item Ampere Rating (A) Amp Code Max Voltage Rating (V) 0.500 .500 600 1.25 1.25 600 2.00 002. 600 Interrupting Rating Agency Approvals Nominal Cold Resistance (Ohms) Nominal Melting I2t (A2sec) 0.560 0.8401 x x .1040 16.51 x x .0450 17.5 x x 50A @ 250 VAC 60 A @600 VAC 100 A @80 VDC 1 I t is calculated at 10 msecs. or less. I t at 10 times rated current has a typical value of: 24 A sec (2.0A), 22 A sec (1.25A), 1.3 A sec (0.5A). 1 2 2 2 2 2 • Typical inductance <40nH up to 500 MHz. • Resistance changes 0.5% for every °C. • Resistance is measured at 10% rated current. 2A 1.25A 100 .500A Average Time Current Curves Temperature Re-rating Curve TIME IN SECONDS 10 1 0.1 0.01 Note: 1. Re-rating depicted in this curve is in addition to the standard re-rating of 25% for continuous operation. 0.001 0.1 1 10 100 1000 CURRENT IN AMPERES GR 1089 Inter-building requirements GR 1089 1st level lighting surge inter-building (Equipment under test can not be damaged and must continue to operate properly) Surge 1 Minimum Minimum Max. Repetitions Peak Peak Rise/Min. Each Voltage Current Decay Polarity (V) (A) (µs) 600 100 10/1000 25 Fuse Choices 1.25, 2.0 2 1000 100 10/360 25 1.25, 2.0 3 1000 100 10/1000 25 1.25, 2.0 4 2500 500 2/10 10 1.25, 2.0 5 1000 25 10/360 5 0.5, 1.25, 2.0 If sufficient series resistance is used, then the 0.5 fuse may be used in test conditions 1-4. © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/18/15 GR 1089 2nd level lightning surge telecom port (Equipment under test shall not become a fire or electrical safety hazard) Surge 1 Alternative Max. Minimum Minimum Rise/Min. Peak Peak Decay Voltage Current (A) (µs) (V) 5000 500 2/10 5000 500/8=625 8/10 Repetitions Fuse Each Choices Polarity 1 0.5, 1.25, 2.0 1 0.5, 1.25, 2.0 The 0.5 fuse will open during these test conditions. The 1.25 & 2.0 will not open thus providing operational compliance. Surface Mount Fuses Surge Resistant > 461 Series TeleLink® Fuse GR 1089 AC power fault 2nd level (fuse can open but must open in a safe and controlled manner) GR 1089 AC power fault 1st level inter-building (fuse not allowed to open) Test 1 2 3 4 5 6 7 8 9 Short Circuit Current (A) 0.33 0.17 Vrms 50 100 200,400, 1 600 1000 1 Diagram Diagram 600 0.5 440 2.2 600 3 1000 5 Primary Fuse Protector Choices Hits Duration 1 1 15 min. 15 min. removed removed 1.25, 2.0 1.25, 2.0 60 1 sec. removed 1.25, 2.0 60 60 1 5 1 1 1 sec. 5 secs. 30 secs. 2 secs. 1.1 secs. 0.4 sec. operative removed removed removed removed in place 1.25, 2.0 1.25, 2.0 1.25, 2.0 1.25, 2.0 1.25, 2.0 1.25, 2.0 Test Circuit Vrms 1 2 3 4 5 120,277 600 600 100-600 Diagram Short Circuit Current (A) 25 60 7 2.2 Diagram Duration Fuse 15 min. 5 secs. 5 secs. 15 min.. 15 min. 0.5, 1.25, 2.0 0.5, 1.25, 2.0 0.5, 1.25, 2.0 0.5, 1.25, 2.0 0.5, 1.25, 2.0 Fuse must open before wiring simulator fuse (MDL 2.0). TIA –968-A (formerly FCC Part 68) Surge Waveforms (fuse can not open during type B events) Surge Metallic A Longitudinal A Metallic B Longitudinal B Voltage (V) 800 1500 1000 1500 Waveform (µs) 10×560 10×160 9×720 9×720 Current (A) 100 200 25 37.5 Repetitions 1 ea. polarity 1 ea. polarity 1 ea. polarity 1 ea. polarity Recommended Fuse 1.25 1.25 1.25 1.25 For the type A events the 0.5 fuse will open, providing non-operational compliance. The 1.25 & 2.0 will not open, providing for operational compliance with TIA-968-A type A surge events. UL 60950 requirements Dimensions UL60950 (EN 60950) (formerly UL 1950) Power Cross (L = longitudinal, M = metallic) Test Number L1 L2 L3 L4 L5 M1 M2 M3 M4 Voltage (V) Current (A) 600 600 600 200 120 600 600 600 600 40 7 2.2 2.2 25 40 7 2.2 2.2 Time 1.5 secs. 5 secs. 30 min. 30 min. 30 min. 1.5 secs. 5 secs. 30 min. 30 min. Fuse Choices 0.5, 1.25, 2.0 0.5, 1.25, 2.0 0.5, 1.25, 2.0 0.5, 1.25, 2.0 0.5, 1.25, 2.0 0.5, 1.25, 2.0 0.5, 1.25, 2.0 0.5, 1.25, 2.0 0.5, 1.25, 2.0 3.25 (.128") 10.10 (.397") LF 1.25A 3.12 (.123") 6.10 (.240") 3.12 (.123") T 3.43 (.135") 12.6 (.496") 1.70 typ (.067") Recommended Pad Layout Selection of test number depends on current limiting F fire enclosure/spacing of end product • 26 AWG line cord removes L1/M1 test requirement • L5 conducted only if product does not pass section 6.1.2 • L2,M2,L3,M3,L4,M4 conducted if not in a fire enclosure Fuse must open before the wiring simulator fuse (MDL 2.0). UL60950 (EN 60950) (formerly UL 1950) Impulse Test and Steady-State Electric Strength Test Test Voltage (V) Current (A) Waveform Repetitions Fuse Choices For handheld units 2500 62.5 10×700ms +/- 10 w/60 secs. rest 0.5, 1.25, 2.0 Non handheld 1500 37.5 10×700ms +/- 10 w/60 secs. rest 0.5, 1.25, 2.0 Impulse Steady-State For handheld units 1500 60Hz 0.5, 1.25, 2.0 Non handheld 1000 60Hz 0.5, 1.25, 2.0 © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/18/15 Surface Mount Fuses Surge Resistant > 461 Series TeleLink® Fuse Soldering Parameters Pb – free assembly Pre Heat - Temperature Min (Ts(min)) 150°C - Temperature Max (Ts(max)) 200°C - Time (Min to Max) (ts) 60 – 120 seconds Average Ramp-up Rate (Liquidus Temp (TL) to peak) 5°C/second max. TS(max) to TL - Ramp-up Rate 5°C/second max. Reflow - Temperature (TL) (Liquidus) 217°C - Temperature (tL) 60 – 90 seconds Peak Temperature (TP) 260+0/–5 °C Time within 5°C of actual peak Temperature (tp) 20 – 40 seconds Ramp-down Rate 6°C/second max. Time 25°C to peak Temperature (TP) 8 minutes max. Do not exceed 260°C Product Characteristics tP TP Critical Zone TL to TP Ramp-up TL TS(max) Temperature Reflow Condition tL Ramp-down Preheat TS(min) 25 tS time to peak temperature (t 25ºC to peak) Time Part Numbering System Materials Body: Ceramic Terminations: Silver-plated Caps Product Marking Brand Logo, Ampere Rating, T 0461 1.25 E R SERIES Operating Temperature -55°C to 125°C AMP Code* Refer to Electrical Characteristics table Moisture Sensitivity Level Level 1, J-STD-020C QUANTITY Code Solderability IEC-60127-4 (215°C immersion, 3 seconds) PACKAGING Code Resistance to Dissolution of Metallization IPC / EIA J-STD-002-Test D 260°C for 120 seconds Thermal Shock MIL-STD-202, Method 107, Test Condition B, -55°C to +125°C, 30 minutes @ each extreme Mechanical Shock MIL-STD-202, Method 213, Test Condition A - Half Sine, 50 G's, 11 msecs. duration High Frequency Vibration MIL-STD-202, Method 204, Test Condition D Moisture Resistance MIL-STD-202, Method 106, 50 cycles Terminal Strength Board deflection per EIA / IS-722, 1mm deflection for 1 minute Terminal Attachment MIL-STD-202, Method 211, Test Condition A, 5 lbs applied to end caps E = 2500 pcs R = Tape and Reel *Example: 2 amp product is 0461002.ER (1.25 amp product shown above) Packaging Packaging Option Packaging Specification Quantity Quantity & Packaging Code 24mm Tape and Reel EIA RS-481-2 (IEC 286, part 3) 2500 ER © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/18/15