GC160 series

GC160
160W Single Output Batte ry Charger
s e ri e s
■  
‧   
‧     
‧    
‧   
‧    
‧      
‧          
‧    
‧   
‧      
‧         
‧  
    
ORDER NO.
OUTPUT CONNECTOR
SAFETY
GC160Axx-R7B (standard model)
4pin power din
TUV / CB / FCC / CE
GC160Axx-AD1 (optional model)
Anderson connector
UL / TUV / CB / FCC / CE
GC160Axx-
xx=12,24,48 ;
=R7B,AD1
SPECIFICATION
ORDER NO.
GC160A12-
GC160A24-
GC160A12
GC160A24
GC160A48
13.6V
27.2V
54.4V
RECOMMENDED BATTERY
60 ~160Ah
CAPACITY
Note.2
30 ~ 90Ah
15 ~ 45Ah
CONTINUOS OUTPUT
CURRENT (Typ.)
10A
5.89A
2.95A
RATED POWER
136W
160.2W
160.5W
SAFETY MODEL NO.
DC VOLTAGE (Typ.)
OUTPUT
GC160A48-
LED INDICATOR
Charging(CC) : RED
Floating charging(CV) : GREEN
VOLTAGE RANGE
Note.3 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF>0.94 / 230VAC
89%
AC CURRENT
INRUSH CURRENT (max.)
1.85A / 115VAC
LEAKAGE CURRENT(max.)
OVERLOAD
Note.4
SHORT CIRCUIT
PROTECTION
CONNECTOR
NOTE
120A / 230VAC
0.75mA / 240VAC
90 ~ 110% rated output power
Protection type : Constant current limiting recovers automatically after fault condition i s removed
Protection type : Hi ccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
90℃±10℃ (RTH2) detect on inside ambient temperature
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ +70 ℃ (Refer to "Derating Curve")
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 5)
EMC EMISSION
EMC IMMUNITY
94%
1A / 230VAC
OVER VOLTAGE
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OTHERS
PF>0.98 / 115VAC at full load
92.5%
20% ~ 90% RH non-condensing
-40 ~ +85 ℃, 10 ~ 95% RH
±0.03% / ℃ (0~50℃ )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1012 (for GC160Axx-AD1 only), TUV EN60950-1 approved
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B, EN61000-3-2,3
MTBF
DIMENSION
PACKING
PLUG
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
274.1K hrs min. MIL-HDBK-217F(25℃)
175*72*35mm (L*W*H)
0.7Kg; 20pcs/15Kg/0.85CUFT(GC160Axx-R7B)
0.77Kg; 20pcs/16.4Kg/1.15CUFT(GC160Axx-AD1)
See page 2 ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested





             ℃   
                 
               
         
                        
 
File Name:GC160-SPEC 2011-08-09
GC160
160W Single Output Battery Charger
Mechanical Specification
Case No.GS16 0A
35
s e r ie s
Unit:mm
175
U L2464 18AWG x4C 1200± 50m m
POWE R LED
30±3mm
23
14
(R7B)
35
175
SJTW 16A W Gx2C 1200±50mm
POWE R LED
30±3mm
(AD1)
Plug Assignment
Charging Curve
DC output connector (standard)
(V,I)
R7B
(KYCON KPP-4S or equivalent)
Stage 1
Stage 2
Constant Current Area
Constant Voltage Area
PIN NO. OUTPUT
2
1
3
4
1,4
+V
2,3
-V
V
100%
AC FG
-V connected to AC FG
Fast Charging
DC output connector (optional)
10%
AD1
[ housing: Anderson 1327FP(red), 1327G6FP(black)
contacts: Anderson 261G2 (45A) or equivalent ]
Red(+V)
Float Charging
Red
Color of L ED
I
TIME
Green
Black(-V)
Derating Curve
Static Characteristics
230VAC
100
100
85
80
80
60
70
100VAC
50
60
40
50
20
-30
40
10
20
30
40
50
60
AMBIENT TEMPERATURE (℃)
70
(HORIZONTAL)
85
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GC160-SPEC 2011-08-09