HER301

MOSPEC
HER301 Thru HER305
Switchmode Power Rectifiers
ULTRAFAST
RECTIFIERS
Designed for use in switching power supplies. inverters and as free
wheeling diodes. These state-of-the-art devices have the following
features:
3.0 AMPERES
50-400 VOLTS
*High Surge Capacity
*Low Power Loss, High efficiency
*Glass Passivated chip junctions
*150℃ Operating Junction Temperature
*Low Stored Charge Majority Carrier Conduction
*Low Forward Voltage , High Current Capability
*Ultrafast 50 & 75 Nanosecond Recovery Time
*Plastic Material used Carries Underwriters Laboratory
Flammability Classification 94V-O
Plating pb free
The marking is indicated by part no. add. “M”.
ex:HER301M~HER305M
DO-201AD
MAXIMUM RATINGS
Characteristic
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
RMS Reverse Voltage
Average Rectifier Forward Current
Non-Repetitive Peak Surge Current
(Surge applied at rate load conditions
halfware, single phase,60Hz )
Operating and Storage Junction
Temperature Range
HER
Symbol
Unit
301
302
303
304
305
VRRM
VRWM
VR50
50
100
200
300
400
V
VR(RMS)
35
70
140
210
280
V
IO
3.0
IFSM
50
TJ , TSTG
A
A
℃
-65 to +150
ELECTRIAL CHARACTERISTICS
Characteristic
HER
Symbol
301
302
303
MILLIMETERS
MIN
MAX
A
5.00
5.60
B
25.40
C
8.50
9.50
D
1.20
1.30
Unit
304
305
V
CASE--Transfer molded
plastic
uA
POLARITY--Cathode indicated
polarity band
Maximum Instantaneous Forward Voltage
(IF=3.0 Amp, TC = 25℃)
VF
Maximum Instantaneous Reverse Current
(Rated DC Voltage, TC = 25℃)
(Rated DC Voltage, TC = 125℃)
IR
Reverse Recovery Time
( IF = 0.5 A, IR =1.0 , Irr =0.25 A )
Trr
50
75
ns
Typical Junction Capacitance
(Reverse Voltage of 4 volts & f=1 MHz)
CP
55
45
PF
1.30
1.00
DIM
5.0
50
HER301 Thru HER305
FIG-3 FORWARD CURRENT DERATING CURVE
HER301-HER303
HER304-HER305
AVERAGE FORWARD RECTIFIED CURRENT (Amp.)
AVERAGE FORWARD RECTIFIED CURRENT (Amp.)
FIG-1 TYPICAL FORWARD CHARACTERISITICS
LEAD TEMPERATURE (℃)
FIG-4TYPICAL JUNCTION CAPACITANCE
HER301-HER303
HER304-HER305
REVERSE VOLTAGE (Volts.)
HER301-HER303
HER304-HER305
PERCENT OF PEAK REVERSE VOLTAGE (﹪)
FIG-5PEAK FORWARD SURGE CURRENT
PEAK FORWARD SURGE CURRENT (Amp.)
INSTANTANEOUS REVERSE CURRENT (uA.)
FIG-2 TYPICAL REVERSE CHARACTERISTICS
JUNCTION CAPACITANCE (PF)
FORWARD VOLTAGE (Volts)
NUMBER OF CYCLES AT 60 Hz
Set time base for 20/50 ns/cm
FIG-6 Reverse Recovery Time Characteristic and Test Circuit Diagram