SFP-GD-BZ45 Datasheet

Optical Communications Systems™
Datasheet
1.25 Gbps Single Fiber Bidirectional 96 km SFP Transceivers
SFP-GD-BZ45 and SFP-GD-BZ54
Highlights
SFP transceiver
Data Rates: 1250 Mbps
Protocols:
- Gigabit Ethernet
Single-mode fiber
Single fiber, bi-directional
Two wavelength options:
- Tx 1490 nm and Rx 1570 nm
- Tx 1570 nm and Rx 1490 nm
32 to 96 km
Simplex LC connector
Digital Diagnostics (SFF-8472)
Hot-swap
Overview
Small Form-Factor Pluggable (SFP) interfaces from MRV Communications provide flexible high speed links in a small
industry standard package. They deliver the deployment options and inventory control that network administrators
demand for growing networks.
SFPs are designed to Multi-Source Agreement (MSA) standards to ensure network equipment compatibility. They are
a perfect addition to MRV ‘s extensive lines of networking equipment.
Visit the MRV website at www.mrv.com or contact your nearest authorized MRV Communications dealer for more
information.
Specifications Overview
Data Rate
1250 Mbps
Tx Wavelength for SFP-GD-BZ45
1490 nm
Tx Wavelength for SFP-GD-BZ54
1570 nm
Tx Power (Minimum)
0 dBm
Tx Extinction Ratio
9 dBm
Tx Disable
Yes
Rx Wavelength for SFP-GD-BZ45
1550 to 1590 nm
Rx Wavelength for SFP-GD-BZ54
1470 to 1510 nm
Rx Sensitivity
-24 dBm
Rx Saturation
-3 dBm
Rx Damage Threshold
0 dBm
Operating Temperature Range
-5 to 70 ºC
Power Consumption
1 Watt
1
Optical Communications Systems™
Datasheet
Transmitter Specifications (Optical)
Parameter
Symbol
Min
Max
Unit
Notes
Pop
0
5
dBm
-
Optical Crosstalk
XT
-
-40
dB
-
Average Launch Power of Off Tx
Poff
-
-45
dBm
-
Extinction Ratio
ER
9
-
dB
-
ps
-
Optical Power
Eye Mask
-
Optical Rise Time (20% to 80% values)
tr
Optical Fall Time (20% to 80% values)
tf
-
260
ps
-
Mean Wavelength for SFP-GD-BZ45
λ
1470
1510
nm
-
Mean Wavelength for SFP-GD-BZ54
λ
1550
1590
nm
-
RMS Width
Δλ
-
1
nm
-
Relative Intensity Noise
RIN
-
-120
dB/Hz
-
Transmitter Reflectance
Optical Return Loss Tolerance
IEEE 802.3ah compliant
-
260
-
-
-
-12
dB
-
ORLT
-
12
dB
-
Symbol
Min
Max
Unit
Notes
Rsens,low/high
-24
-3
dBm
1
Receiver Specifications (Optical)
Parameter
Receive Power
Damage Threshold
Pin,damage
0
-
dBm
-
Wavelength for SFP-GD-BZ45
λ
1550
1590
nm
-
Wavelength for SFP-GD-BZ54
λ
1470
1510
nm
-
LOS Assert
-
-45
-
dBm
-
LOS De-assert
-
-
-24
dBm
-
LOS Hysteresis
-
0.5
-
dB
-
Receiver Reflectance
-
-
-12
dB
-
Notes:
1.
Measured at 10-12 BER, PRBS 27-1, 9 dB ER
Digital Diagnostics
Parameter
Range
Accuracy
Unit
Temperature
-5 to 70
±3
ºC
Calibration Bit Value
Internal
1/256 C
Formula
Tc(C)=Tad(16 bit signed twos complement)/256
Voltage
0 to Vcc
± 0.1
V
Internal
100μV
V(Volts)=Vad(16 bit unsigned integer)*0.1
Bias Current
0 to 120
±5
mA
External
-
I(mA)=Islope*Iad(16 bit unsigned integer)+Ioffset
TX Power
0 to 3.5
±3
dBm
External
-
TX_PWR(μW)=TX_PWRslope*TX_PWRad(16 bit
unsigned integer +TX_PWRoffset
RX Power
-24 to -3
±3
dBm
External
-
RX_PWR(μW)=A0+A1*x+A2*x^2+A3*x^3+A4*x^4
2
Optical Communications Systems™
Datasheet
General Operations
Parameter
Symbol
Min
Max
Unit
Supply Voltage
Vcc
3.135
3.465
V
Notes
-
Total Current
Icc
-
300
mA
-
Power Supply Noise Rejection
PSR
100
-
mVp-p
-
Operating Temperature of SFP Case
Topr
-5
70
ºC
1
Storage Temperature
Tstg
-40
85
ºC
-
Data Rate
DR
-
1250
Mbps
-
Symbol
Min
Max
Unit
Notes
Rin
80
120
Ω
-
PECL Single Ended Data Input Swing
Vin,p-p
250
1200
mV
-
TxFault_Fault
Vfault
2
Vcc
V
-
Notes:
1.
Maximum Relative Humidity is 85%, non-condensing
Transmitter Specifications (Electical)
Parameter
Input Differential Impedence
Vnormal
Vee
Vee+0.5
V
-
TxDisable_Disable
TxFault_Normal
Vd
2
Vcc
V
-
TxDisable_Enable
Ven
Vee
Vee+0.8
V
-
Parameter
Symbol
Min
Max
Unit
Notes
PECL Single Ended Data Output Swing
Receiver Specifications (Electrical)
Vout, p-p
185
800
mV
-
Data Output Rise Time
tr
-
175
ps
-
Data Output Fall Time
tf
-
175
ps
-
Notes
Electrical Specifications and Timing
Parameter
Symbol
Min
Max
Unit
Tx Disable Negate Time
t_on
-
1
ms
-
Tx Disable Assert Time
t_off
-
10
μs
-
Time to Initialize, Including Reset of Tx Fault
t_init
-
300
ms
-
Tx Fault Assert Time
t_fault
-
100
μs
-
Tx Disable To Reset
t_reset
10
-
μs
-
LOS Assert Time
t_loss_on
-
100
μs
-
LOS De-assert Time
t_loss_off
-
100
μs
-
Serial ID Clock Rate
f_serial_clock
-
100
KHz
-
RX_LOS Voltage (High)
RX_LOSH
2
Vcc
V
-
RX_LOS Voltage (Low)
RX_LOSL
-
0.8
V
-
LOS Output Voltage-Fault
VLOS fault
2
Vcc
V
VLOSnormal
Vee
Vee+0.5
V
-
MOD_DEF (0:2)-High
VH
2
Vcc
V
-
MOD_DEF (0:2)-Low
VL
Vee
Vee+0.5
V
-
LOS Output Voltage-Normal
3
Optical Communications Systems™
Datasheet
Pin
Function
Name / Description
1
VeeT
Module Transmitter Ground
Notes
-
2
TX_FAULT
Open Collector
-
3
TX_DISABLE
Internally Pulled High
-
4
MOD_DEF2
Serial Data Input
-
5
MOD_DEF1
Serial Clock Input
-
6
MOD_DEF0
Internally Grounded
-
7
NC
Not Connected
-
8
LOS
Open Collector
-
9
VeeR
Module Receiver Ground
-
10
VeeR
Module Receiver Ground
-
11
VeeR
Module Receiver Ground
-
12
RXD-
Receiver Data Negative
-
13
RXD+
Receiver Data Positive
-
14
VeeR
Module Receiver Ground
-
15
VccR
Module Receiver Power Supply
-
16
VccT
Module Transmitter Power Supply
-
17
VeeT
Module Transmitter Ground
-
18
TXD+
Transmitter Data Positive
-
19
TXD-
Transmitter Data Negative
-
20
VeeT
Module Transmitter Ground
-
Outline Drawing
Units in mm
4
Optical Communications Systems™
Datasheet
Bail Latch
Color
Distance
Range
(km)
Digital
Diagnostics
SFP Bidirectional Transceiver
1250
1490
1570
LC
Yes
Purple
32 - 96
SFP-GD-BZ54
SFP Bidirectional Transceiver
1250
1570
1490
LC
Yes
Orange
32 - 96
Tx
Connector
Type
Description
SFP-GD-BZ45
Data Rate
(Mbps)
Model
Wavelength
(nm)
Ordering Information
Rx
Regulatory and Industry Compliances
Class 1 Laser Product, complies with EN 60825-1 and 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50. dated June 24, 2007
MSA SFF-8074i; Telcordia GR-468, Digital Diagnostic SFF-8472;
Certified by one or more of the following agencies: TÜV, UL, CSA
RoHS Directive; China RoHS; California RoHS Law, REACH Directive SVHC; WEEE Directive
The Quality Management System is certified to ISO 9001 by QMI-SAI Global
The Environmental Management System is in compliance with ISO 14001
Warnings
Handling Precautions: This device is susceptible to damage as a result of electrostatic descharge (ESD). A static free environment is highly
recommended. Follow guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
MRV has more than 50 offices throughout the world. Addresses, phone numbers and fax numbers are listed at www.mrv.com.
Please e-mail us at [email protected] or call us for assistance.
MRV Los Angeles
20415 Nordhoff Street
Chatsworth, CA 91311
800-338-5316
818-773-0900
MRV Boston
300 Apollo Drive
Chelmsford, MA 01824
800-338-5316
978-674-6800
MRV International
Business Park Moerfelden
Waldeckerstrasse 13
64546 Moerfelden-Walldorf
Germany
Tel. (49) 6105/2070
Fax (49) 6105/207-100
All statements, technical information, and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the
accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information.
MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders.
MRV-OP-SFPGDBZ4554-072010
3020060-001 Rev. A2
Copyright ©2010 MRV Communications, Inc. All Rights Reserved.