SME Micro-Power Hall Sensors FINAL

A Global Leader in the Design, Development, and
Manufacture of Sensors and Magnetic Components
www.standexmeder.com
www.standexmeder.com
Micro-Power
Hall Effect Sensors
MH04, MH21 and MH11/M12
Contact Information:
Standex-Meder Electronics
World Headquarters
4538 Camberwell Road
Cincinnati, OH 45209 USA
Standex-Meder Hall Effect Sensors offer solid state reliability, low power consumption, and
consistent activation points over a wide temperature range in a rugged and environmentally
isolated package.
Micro-Power versions operate on 2.5-3.5V battery voltage with only 5μA average supply
current vs. the industry average of 5mA
Custom options include: output- switch, latch, analog, angular, etc., high temperature
resistance, package design and much more.
Standex Americas (OH)
+1.866.STANDEX
Standex-Meder specializes in customizing designs to specific customer needs for a wide range
of applications. Please contact us to provide the optimal solution for your specific needs.
(+1.866.782.6339)
[email protected]
Dimensions in mm (inches)
Meder Americas (MA)
+1.800.870.5385
H21
MH04
[email protected]
Standex-Meder Asia (Shanghai)
+86.21.37820625
[email protected]
Standex-Meder Europe (Germany)
MH21
+49.7731.8399.0
[email protected]
MH11/M12
Version 01
Page 1 of 2
A Global Leader in the Design, Development, and
Manufacture of Sensors and Magnetic Components
Micro-Power Hall Effect Sensor
www.standexmeder.com
Electrical & Environmental Characteristics
Micro-Power Switch
Min
Typ
Max
Specification
Conditions
Supply Voltage
Output Leakage Current
Output On Voltage
Awake Time
Period
Duty Cycle
Chopping Frequency
Operating
VOUT = Max Voltage
2.5
Chip Awake
Chip Asleep
VCC = 3.5V
VCC = 12V
Supply Current
2.75
<1
100
45
45
0.1
340
3.5
1
300
90
90
3
24
10
500
185
800
2
8
10
6.7
Operating Temperature
Storage Temperature
*Higher temperature versions available
Standard Switch & Latch
Min
Typ
Max
-40
-65
4
+85*
+105
-40
-65
4
+85*
+105
Unit
V
µA
mV
µs
ms
%
kHz
mA
µA
µA
mA
C
C
Magnetic Characteristics
Specification
Conditions
Operation Point
Release Point
Hysteresis
VOUT = Low (Output On)
VOUT = High (Output Off)
Micro-Power
Switch (Typ)
Standard
Switch (Typ)
Standard
Latch (Typ)
Unit
37
31
5.9
95
70
25
22
-23
45
G
G
G
Circuit Diagram for 3-wire Hall Effect Sensors
Notes:
-
Add external pull-up resistor (RL) for sinking
output between VCC and VOUT.
Add external bypass capacitor (CBYP) close to the
sensor to reduce external noise as needed.
Part Number Builder
Series
MH04, MH21,
MH11/M12
Hall Model
10 (Micro-Power)*
11 (Standard)
Hall Function
S (Switch)
L (Latch)
A (Analog)
*Micro-Power version only
available as switch function
Cable Length (mm)
500*
*other lengths available
Termination
W (5mm stripped and tinned)*
*other terminations available
Example Part Number: MH04-10S-500W
Version 01