Screw Terminal type Bracket and bushing

Dimension of bracket / bushing for screw terminal type.
Screw terminal type can be supplied with the following bracket and bushing.
Here is standard position and angle of the bracket / bushing. Please contact us if you have specific requirement.
There is a restriction for capacitors size.
Method to mount with metal bracket
For φ 35 : 2-leg brackets(standard)
φ35 Screwφterminal
35 Screw
type
terminal type
Hexagenal headed
Hexagenal
bolt (M5)
headed bolt (M5)
Bottom plate Bottom
plate
Sleeve
L+3MAX.
L+3MAX.
24
24
29±1
29±1
For φ 51 or greater : 3-leg brackets(standard)
Bottom plate
3.5
7
(mm)
0°
12
Hexagenal headed bolt
φD
Symbol
60
°
Sleeve
10
45±1
3.5
6±1
10
45±1
30°
30°
12.7±1
6±1
+7
P
A
T
S
U
H
h
W
W±1
D +2MAX.
Pressure relief vent
h
L+
MAX.
U
A±2
U
S
Hexagenal headed bolt
Sleeve
83.7
P
A±2
T
P
A
T
S
U
H
h
W
D +2MAX.
W±1
90
100
32.5
38.5 7.5 5
12 20
15
22
6
3
38.1
43 8
5
14 25
20
28.6
6
3
44.5 49.2 7
5
14
30 24
31.8
6
3
50.8 58.5 8
5
18 35
25
31.8
6
3
56.3
62
8
5
16
36
30
41.5
10
4
Pressure relief vent
±1
Resin bushing Hexagenal headed bolt
(M5)
(mm)
Sleeve
φD
30°
MAX.
76.2
Bottom plate
h
L+
63.5
Symbol
H±1
51
±1
Applicable to φ 51 or greater : 2-leg brackets
Bottom plate
T
P±2
B
H±1
51
33.2
40
6
4.5
14
25
L+3MAX.
15
22
6
3
63.5
76.2
40.5
46.5 7
4.5
14
74.4 35
20
28.6
6
3
46.5
53
6
4.5
14
35
20
31.8
6
3
Pressure
relief vent
90
φ4.5
53
59
6
4.5
14
35105
20120
31.8
6
3
31.8±1
10
15±0.5
+
88.2
10
15±0.5
35 +2MAX.
12.7±1
35 +2MAX.
Pressure relief ventPressure relief vent
Method to mount with resin bushing.
150
Pressure
relief vent
MAX.
Sleeve
30
38
105
120
19
Plastic nut
Plastic washer
Pressure
relief vent
L+
1
MAX.
Stud bolt
φD
Symbol
W
(mm)
51
63.5
76.2
22
65.7
28.6
31.8
6
3
L+3MAX.
6
3
6
3
Pressure relief
vent relief vent
Pressure
±1
31.8±1
1
102.5
15±1
L+ MAX.
95.5
MAX.
M12
2
18
Pressure relief vent
19
4
φ12.5
φ22.6
18
φ35
Bracket hole : φ30.5mm(MIN.)
90
57.5
63.531.8
18
19
M12
30
38
30
38
Hexagenal headed bolt (M5)
°
120
19
L+
18
A nut for stud bolt. (option)
Hexagenal headed bolt
Resin bushing
φ6.0
Pressure relief vent
1
D +2MAX.
D +2MAX.
D +2MAX.
Sleeve
57.5
63.5
65.7
L+3MAX.
M12
Stud bolt
M12
Bottom plate
M12
30
38
74.4
151
L
Method
to mount with
stud bolt.
Applicable toHexagenal
φ 51 toHexagenal
φ 90boltheaded bolt
headed
Sleeve Sleeve
Bottom plate
Pressure
relief vent
31.8±1
31.8±1
D +2MAX.
88.2
83.7
Stud bolt
M12
+
Hexagenal headed bolt (M5)
°
120
Hexagenal
headed bolt
φ4.5
Sleeve
L+3MAX.
150
Resin bushing
Sleeve
Bottom plate
102.5
Bottom plate
Applicable to φ 90 and L
Resin bushing Hexagenal headed bolt (M5)
Sleeve
95.5
Applicable to φ 76.2 and L
Bottom plate
olt
1
Sleeve
S
late
ALUMINUM ELECTROLYTIC CAPACITORS
φ6.0
6
3
CAT.8100D