AC Motor Start Aluminum Electrolytic Capacitors MS/MD Series, +60ºC/+70°C Overview Applications KEMET's MS/MD Series of aluminum electrolytic capacitors are designed for itermittent duty only and capable of withstanding the AC voltage applied to the motor during starting. The capacitor construction is comprised of either double anode or O-style (double anode and floating cathode) windings, which are housed in a molded plastic case. KEMET's MD Series is VDE approved to IEC 60252-2 for the defined ratings. KEMET's MS/MD Series is a range of aluminium electrolytic capacitors specifically designed for AC operation which helps to start the motor by providing a leading current to the auxiliary winding. The capacitor is not permanently connected to the winding of the motor and is usually switched off automatically after starting. Benefits • Intermittent AC motor starting • 6.3 mm double amp tags (quick connect types) • VDE approved to IEC 60252–2 Part Number System 080 MS 12 AA M A 1 STD Capacitance Code (µF) Rating Voltage (VAC) Size Code Manufacturing Style Capacitance Tolerance Terminal Code Version A = -0% +25% K = ±10% 1 = Double amp tag STD = Standard Example: 080 = 80 µF 120 = 120 µF MS = Motor start single rating MD = Motor start dual rating 12 = 120 22 = 220 26 = 260 See Dimension Table M = Molded case One world. One KEMET © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com A4041_MS_MD • 11/24/2014 1 AC Motor Start Aluminum Electrolytic Capacitors – MS/MD Series, +60ºC/+70°C Performance Characteristics Item Performance Characteristics MD (Dual voltage rating) MS (Single voltage rating) 25 – 750 µF 25 – 750 µF 120 – 360 VAC 50 Hz 120 – 260 VAC 50 Hz Operating Temperature -20°C to +70°C -20°C to +60°C Capacitance Tolerance ±10%, -0% +25% ±10%, -0% +25% 500 hours at +70°C, 1.1 VR (specified duty cycle) 500 hours at +60°C, 1.1 VR (specified duty cycle) 2 years 2 years Series Capacitance Range Rated Voltage Operational Lifetime Shelf Life Standards IEC 60252–2: AC Motor Capacitors - Part 2: Motor Start Capacitors VDE Approvals to IEC 60252–2 Rated Voltage 220 V 260 V Capacitor Type MD MD Capacitance (µF) (Note 1) (Note 2) 30 AA 40 AA AB AB 50 AA AB AB 60 AA AB AB 70 AB AB 80 AB AC AB 90 AC AC 100 AC AC 120 AC AC 125 AC AC Note 1: Duty cycles approved 220 V @ SD = 3 & ED = 1.7% 300 V @ SD = 1 & ED = 0.1% Note 2: Duty cycles approved 260 V @ SD = 3 & ED = 1.7% (40 – 125 µF) 330 v @ SD = 1 & ED = 0.55% (40 – 125 µF) 360 v @ SD = 1 & ED = 0.33% (90 – 125 µF) General approval notes: • Valid for both ±10% and -0 +25% tolerance. • Valid for intermediate capacitance Values in increments of 1 µF between 30 µF and 100 µF, and in increments of 5 µF between 100 µF and 125 µF. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com A4041_MS_MD • 11/24/2014 2 AC Motor Start Aluminum Electrolytic Capacitors – MS/MD Series, +60ºC/+70°C Dimensions – Millimeters L Maximum D Pressure Relief Vent D2 Size Code D Dimensions in mm D2 ±0.5 Maximum 38 38 38 39 39 39 75 90 116 ±0.5 AA AB AC L Power Factor The tangent of the loss angle for motor start capacitors shall not exceed 0.1 and shall be calculated as follows: true watts W Tan δ = = apparent watts VxI Duty Cycle The standard rating is 1.67% or 1/60th full time and corresponds to a maximum duty of 20 starts, each of three seconds duration per hour. It is expressed as 3/1.67 (a 3 minute cycle with 1.67% duration during which the capacitor may be energized). If the same capacitor is to be used for a duty cycle of 60 starts per hour the cycle duration will be 1 minute. The operation time per cycle will then have to be reduced to 1.67% of 1 minute (i.e. 1 second). Alternative duty cycles are available on request. Presence of Run Capacitor When the motor is fitted with both starting and run capacitors, consideration should be given to fitting of the appropriate discharge resistor to the starting capacitor. This is to protect the run capacitor from damage through discharge of the starting capacitor. Container Form Cylindrical mouldings, meeting creepage and clearance distances, according to IEC 60335–1 and flammability ratings according to UL94–V1. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com A4041_MS_MD • 11/24/2014 3 AC Motor Start Aluminum Electrolytic Capacitors – MS/MD Series, +60ºC/+70°C Discharge Resistors A discharge resistor may be fitted to a motor start capacitor to prevent electrical overstress of the capacitor and/or for safety reasons. In accordance with IEC 60252, the resistor value should be such that it reduces the voltage on the capacitor, from the line voltage to less than 50 V within 60 seconds. The resistor value may be approximated as follows: R(kOhms) = T/Rated Capacitance (µF) AC Voltage T Resistor Value (kOhms) Wattage 120 50000 5.6 2W 220 32000 15 2W 260 30000 33 0.5W 280 28000 56 1W 330 26000 82 2W 100 1W Environmental Compliance As an environmentally conscious company, KEMET is working continuously with improvements concerning the environmental effects of both our capacitors and their production. In Europe (RoHS Directive) and in some other geographical areas like China, legislation has been put in place to prevent the use of some hazardous materials, such as lead (Pb), in electronic equipment. All products in this catalog are produced to help our customers’ obligations to guarantee their products and fulfill these legislative requirements. The only material of concern in our products has been lead (Pb), which has been removed from all designs to fulfill the requirement of containing less than 0.1% of lead in any homogeneous material. KEMET will closely follow any changes in legislation world wide and makes any necessary changes in its products, whenever needed. Some customer segments such as medical, military and automotive electronics may still require the use of lead in electrode coatings. To clarify the situation and distinguish products from each other, a special symbol is used on the packaging labels for RoHS compatible capacitors. Because of customer requirements, there may appear additional markings such as LF = Lead Free or LFW = Lead Free Wires on the label. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com A4041_MS_MD • 11/24/2014 4 AC Motor Start Aluminum Electrolytic Capacitors – MS/MD Series, +60ºC/+70°C Table 1A – Ratings & Part Number Reference VAC 120 120 120 120 120 120 120 120 120 120 120 120 VAC Rated Capacitance Case Size Duty Cycle Minimum (µF) Maximum (µF) Capacitance Tolerance D x L (mm) 120 VRMS 25 25 85 90 120 130 25 25 85 90 120 130 325 360 460 510 670 750 325 360 460 510 670 750 -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% 38 x 75 38 x 75 38 x 90 38 x 90 38 x 116 38 x 116 38 x 75 38 x 75 38 x 90 38 x 90 38 x 116 38 x 116 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% Capacitance Tolerance Case Size Rated Capacitance 150 VRMS 0.55% 0.55% 0.55% 0.55% 0.55% 0.55% Duty Cycle Part Number Approval VDE CQC (1)MS12AAMA1STD (1)MS12AAMK1STD (1)MS12ABMA1STD (1)MS12ABMK1STD (1)MS12ACMA1STD (1)MS12ACMK1STD (1)MD12AAMA1STD (1)MD12AAMK1STD (1)MD12ABMA1STD (1)MD12ABMK1STD (1)MD12ACMA1STD (1)MD12ACMK1STD - x x x x x x Part Number VDE CQC (1) Insert capacitance code. Table 1B – Ratings & Part Number Reference VAC 220 220 220 220 220 220 220 220 220 220 220 220 VAC Rated Capacitance Minimum (µF) Maximum (µF) 30 30 40 40 55 65 30 30 40 40 80 80 65 70 90 100 130 150 60 60 80 80 125 125 Rated Capacitance Capacitance Case Size Tolerance D x L (mm) -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% 38 x 75 38 x 75 38 x 90 38 x 90 38 x 116 38 x 116 38 x 75 38 x 75 38 x 90 38 x 90 38 x 116 38 x 116 Capacitance Tolerance Case Size Duty Cycle 220 VRMS 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 300 VRMS 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% Duty Cycle Part Number Approval VDE CQC (1)MS22AAMA1STD (1)MS22AAMK1STD (1)MS22ABMA1STD (1)MS22ABMK1STD (1)MS22ACMA1STD (1)MS22ACMK1STD (1)MD22AAMA1STD (1)MD22AAMK1STD (1)MD22ABMA1STD (1)MD22ABMK1STD (1)MD22ACMA1STD (1)MD22ACMK1STD x x x x x x x x x x x x Part Number VDE CQC (1) Insert capacitance code. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com A4041_MS_MD • 11/24/2014 5 AC Motor Start Aluminum Electrolytic Capacitors – MS/MD Series, +60ºC/+70°C Table 1C – Ratings & Part Number Reference VAC 260 260 260 260 260 260 260 260 260 260 260 260 VAC Rated Capacitance Minimum (µF) Maximum (µF) 25 25 35 35 50 55 25 25 40 40 90 90 55 60 75 85 110 125 50 55 80 80 125 125 Rated Capacitance Capacitance Case Size Tolerance D x L (mm) -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% -0/+25% ±10% 38 x 75 38 x 75 38 x 90 38 x 90 38 x 116 38 x 116 38 x 75 38 x 75 38 x 90 38 x 90 38 x 116 38 x 116 Capacitance Tolerance Case Size Duty Cycle 260 VRMS 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 1.67% 330 VRMS 0.55% 0.55% 0.55% 0.55% 0.55% 0.55% 360 VRMS 0.33% 0.33% Duty Cycle Part Number Approval VDE CQC (1)MS26AAMA1STD (1)MS26AAMK1STD (1)MS26ABMA1STD (1)MS26ABMK1STD (1)MS26ACMA1STD (1)MS26ACMK1STD (1)MD26AAMA1STD (1)MD26AAMK1STD (1)MD26ABMA1STD (1)MD26ABMK1STD (1)MD26ACMA1STD (1)MD26ACMK1STD x x x x x x x x x x x x Part Number VDE CQC (1) Insert capacitance code. Print Detail • • • • • • • KEMET Logo Rated capacitance Capacitance tolerance Rated voltage Climatic Category Article code Date of manufacture & Batch No. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com A4041_MS_MD • 11/24/2014 6 AC Motor Start Aluminum Electrolytic Capacitors – MS/MD Series, +60ºC/+70°C KEMET Corporation World Headquarters Europe Asia Southern Europe Paris, France Tel: 33-1-4646-1006 Northeast Asia Hong Kong Tel: 852-2305-1168 Mailing Address: P.O. Box 5928 Greenville, SC 29606 Sasso Marconi, Italy Tel: 39-051-939111 Shenzhen, China Tel: 86-755-2518-1306 www.kemet.com Tel: 864-963-6300 Fax: 864-963-6521 Central Europe Landsberg, Germany Tel: 49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel: 954-766-2800 Kamen, Germany Tel: 49-2307-438110 North America Northern Europe Bishop’s Stortford, United Kingdom Tel: 44-1279-460122 2835 KEMET Way Simpsonville, SC 29681 Southeast Lake Mary, FL Tel: 407-855-8886 Espoo, Finland Tel: 358-9-5406-5000 Northeast Wilmington, MA Tel: 978-658-1663 Beijing, China Tel: 86-10-5829-1711 Shanghai, China Tel: 86-21-6447-0707 Taipei, Taiwan Tel: 886-2-27528585 Southeast Asia Singapore Tel: 65-6586-1900 Penang, Malaysia Tel: 60-4-6430200 Bangalore, India Tel: 91-806-53-76817 Central Novi, MI Tel: 248-306-9353 West Milpitas, CA Tel: 408-433-9950 Mexico Guadalajara, Jalisco Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com A4041_MS_MD • 11/24/2014 7 AC Motor Start Aluminum Electrolytic Capacitors – MS/MD Series, +60ºC/+70°C Disclaimer All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com A4041_MS_MD • 11/24/2014 8