B-X(S)D-2W Series

2B-X(S)D Series
Fixed Input,Isolated 2W Single Output DC/DC Converters
SELECTION GUIDE
Input
Voltage
(V)
Output
Voltage
(V)
Output
Current
(MA)
Input Current
(Rated Load)
(MA)
Efficiency
Order code
2B0503XS
5
3.3
400
470
FEATURES
2B0505XS
5
5
400
2B0505XD
5
5
RoHS compliant
2B0509XS
5
2B0509XD
◆
◆
◆
◆
◆
◆
I/O isolation voltage 1000VDC
Operating Temperature: -40℃~﹢85℃
High efficiency up to 81%
Fully encapsulated toroidal magnetics
Internal SMD construction
◆
Power density up to 0.85W/cm3
◆
No electrolytic or tantalum capacitors
◆
◆
5V,9V,12V and 15V output
No heat sink required
◆
Dual output from a single input rail
◆
UL 94V-0 package material
◆
No external components required
◆
◆
◆
Industry standard pinout
Power sharing on output
MTTF up to 3.9 million hours
MODEL SELECTION
①
②
③
④
⑤
2B 05 05 X S
①Product Series
③Output Voltage
⑤SIP Package
②Input Voltage
④Fixed Input
MTTF1
(%)
Isolation
Capacitance
(PF)
(KHRS)
85
30
3988
470
81
33
3956
400
470
81
33
3956
9
222
455
84
40
3682
5
9
222
455
84
40
3682
2B0512XS
5
12
167
450
84
40
3299
2B0512XD
5
12
167
450
84
40
3299
2B0515XS
5
15
133
450
84
40
2833
2B0515XD
5
15
133
450
84
40
2833
2B0524XS
5
24
83
442
82
40
2766
2B0524XD
5
24
83
442
84
40
2766
2B1205XS
12
5
400
200
81
40
2519
2B1205XD
12
5
400
200
81
40
2519
2B1209XS
12
9
222
190
83
61
2405
2B1209XD
12
9
222
190
83
61
2405
2B1212XS
12
12
167
190
85
74
2235
2B1212XD
12
12
167
190
85
74
2235
2B1215XS
12
15
133
185
85
68
2011
2B1215XD
12
15
133
185
85
68
2011
2B1224XS
12
24
83
99
84
68
1800
2B1224XD
12
24
83
99
83
69
1789
2B1515XS
15
15
133
185
85
68
2012
2B1515XD
15
15
133
185
85
70
2015
2B2405XS
24
5
400
104
80
60
2000
2B2406XS
24
6
333.3
102
82
58
1850
2B2409XS
24
9
222
100
83
65
1980
2B2412XS
24
12
167
99
84
78
1800
2B2415XS
24
15
133
99
84
58
1760
2B2424XS
24
24
83
99
84
68
1800
2B2405XD
24
5
400
104
80
60
1850
2B2409XD
24
9
222
100
83
65
1886
2B2412XD
24
12
167
99
84
78
1986
2B2415XD
24
15
133
99
84
58
1801
2B2424XD
24
24
83
99
84
68
1850
add Suffix “P” for Continuous Short Circuit Protection, e.g. 2B0505XDP
Input Characteristics
APPLICATIONS
The 2B-X(S)D series of DC/DC converters
is particularly suited to isolating and or
converting DC power rails. The galvanic
isolation allows the device to be configured to
provide an isolated negative rail in systems
where only positive rails exist. The wide
temperature range guarantees startup from
-40°C and full 2 watt output at 85℃. Pin
compatibility with the B_XLS series ensures
ease of upgradeability.
MICRODC R ESERVES THE COPYRIGHT
Parameter
Voltage range
Conditions
Min
Typ
Max.
Continuous operation,5V input types
4.5
5
5.5
Continuous operation,12V input types
10.8
12
13.2
Continuous operation,24V input types
21.6
24
26.4
7.5
15
Reflected ripple current
Units
V
mA p-p
Absolute Maximum Ratings
Short-circuit protection2
1 second
Lead temperature 1.5mm from case for 10 seconds
300℃
Internal power dissipation
550mW
Input voltage VIN,B05 types
7V
Input voltage VIN,B12 types
15V
1.Calculated using MIL-HDBK-217FN2 calculation model with nominal input voltage at full load.
2.Supply voltage must
be disconnected at
the end of
the short circuit duration.
All specifications typical at TA=25°C,nominal input voltage and rated output current unless otherwise specified.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 5
2B-X(S)D Series
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min.
Rated Power
TA=-40℃ to 85℃
0.2
Voltage Set Point Accuracy
See tolerance envelope
Line regulation
Typ.
Max.
Units
2
W
High VIN to low VIN
1.05
1.2
%%
3.3V output
12
20
%
5V output
12.8
15
%
Load regulation
9V output
8.3
15
%
10% to 100% load
12V output
6.8
15
%
15V output
6.3
15
%
24V output
6.0
15
%
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2s and output capacitance of 10F, are saw in the table below. The product
series will start into a capacitance of 47F with an increased start time, however, the maximum recommended output capacitances 10F
Typical Start-Up Wave Form
Start-up time
2B0505XS
444
2B0509XS
1120
2B0512XS
1930
2B0515XS
3470
2B1205XS
409
2B1209XS
1320
2B1212XS
1320
2B1215XS
2270
Isolation Characteristics
Parameter
Conditions
Min.
Isolation voltage
Flash tested for 1 second
1000
Typ.
Max.
Units
VDC
Resistance
Viso= 500VDC
1000
MΩ
Conditions
Min.
General Characteristics
Parameter
Switching frequency
Typ.
Max.
60
Units
kHz
Temperature Characteristics
Parameter
Conditions
Min.
Specification
All output types
-40
85
-50
125
Storage
Case temperature above
ambient
http://www.microdc.cn
Typ.
Max.
B0505XS output types
30
B1205XS output types
25
All other output types
20
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Units
℃
Page 2 of 5
2B-X(S)D Series
Temperature derating graph
Tolerance envelope
The voltage tolerance envelope shows typical load regulation characteristics for this
product series. The tolerance envelope is the maximum output voltage variation due
to changes in output
OUTPUT RIPPLE REDUCTION
Output ripple reduction
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: Ceramic chip capacitors are recommended. It is required that the ESR(Equivalent Series Resistance)should be as low as possible.X7R types are recommended.
The voltage rating should be at least twice(except for 15V output),the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be
such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF(Self Resonant Frequency) should be >20MHz.
CHARACTERISATION TEST METHODS
Ripple & Noise Characterization Method
All measurement to be taken with the following components connected to the UUT as detailed below. 50 Ohm coax cable, solder
connections one end, BNC plug at the other end.
Ripple and noise measurements are performed with the following test configuration.
C1
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
C2
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less than 100mΩ at 100 KHz
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon fi lm, ±1% tolerance
R2
50Ω BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specfied values.
Differential Mode Noise Test Schematic
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 3 of 5
2B-X(S)D Series
Technical notes
ISOLATION VOLTAGE
"Hi Pot Test","Flash Tested","Withstand Voltage","Dielectric Withstand Voltage"&”Isolation Test Voltage" are all terms that relate to the same thing, a test voltage.
Applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Professional Power Module B series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1KVDC for 1 second.
A question commonly asked is,"What is the continuous voltage that can be applied across the part in normal operation?"
The B_X(S)D series has been recognized by Underwriters Laboratory for functional insulation. Both input and output should normally be maintained within SELV limits i.e. less than
42.4V peak, or 60VDC.The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier, but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-acssible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials.
Construction and environment. The B series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing. but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
SIP Package
FOOTPRINT
FOOTPRINT
SIP7
SIP7
DIP14
DIP Package
PIN
Function
PIN
Function
1
+Vin
-Vin
-Vout
+Vout
1
GND
NC
0V
+V0
No Pin
Vin
2
4
6
7
8
9
11
NC No connection
14
Specifcations can be changed any time without notice.
No parallel connection or plug and play.
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
All dimensions in inches ±0.01(mm±
0.01(mm±0.25mm).
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless
All pins on a 0.1(2.54) pitch and within ±0.01(0.25)of true position.
Weight: 2.8g(SIP)
otherwise specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
4.2g(DIP)
RECOMMENDED FOOTPRINT DETAILS
4 Pin SIP Package
14 Pin DIP Package
Unless otherwise stated all dimensions in inches (mm) 0.5mm
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 4 of 5
2B-X(S)D Series
TUBE OUTLINE DIMENSIONS
4 PIN SIP Tube
Unless otherwise stated all dimensions in inches (mm) ±0.5mm.
14 PIN DIP Tube
Tube length (14 Pin DIP) : 20.47 (520mm ±2mm).
Tube length (4 Pin SIP) : 20.47 (520mm ±2mm).
Tube Quantity :25
RoHS COMPLIANT INFORMATION
Microdc Professional Power Module,Inc.
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C
Tel:0086-20-86000646 E-mail:[email protected]
for 10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte
Website:http://www.microdc.cn
Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this series are
Microdc Professional Power module,Inc.makes no representation that
backward compatible with Sn/Pb soldering systems.
the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or
REACH COMPLIANT INFORMATION
future patent rights. Specifications are subject to change without notice.
This series has proven that this product does not contain harmful chemicals, it also has harmful chemical
©2010
substances through the registration, inspection and approval.
Microdc Professional Power Module, Inc. Guangzhou
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 5 of 5