WRA-YLS-3W Series

WRA-YLS-3W Series
,I
solated
&R
egulated Dual Output SIP
10 DC/DC Converter
Wide Input
nput,I
,Isolated
solated&R
&Regulated
SIP10
SELECTION GUIDE
order code
Input
Rated Output
Voltage
Voltage
Output Current
Min Load3
Full Load
Input
Efficiency
Isolation
Current2
(MIN.)
Capacitance
V (NOM.)
V
mA
mA
mA
%
pF
WRA2412YLS-3W
24
±12
±32
125
157
81
36
FEATURES
WRA2415YLS-3W
24
±15
±25
100
155
82
36
WRA4812YLS-3W
48
±12
±32
125
78
78
40
RoHS compliant
WRA4815YLS-3W
48
±15
±25
100
78
78
40
◆
Compact SIP10 form factor
◆
2:1 Wide range voltage input
INPUT CHARACTERISTICS
◆
Continuous short circuit protection with current
◆
Fold back
Parameter
Conditions
Voltage range
Operating temperature range –40°C to +85°C
◆
Refected ripple current
0.5% Load Regulation
◆
◆
Shutdown Power
1kVDC Isolation
Min.
Typ.
Max.
All WRA24XX types
18
24
36
All WRA48XX types
36
48
72
All WRA24 types when 10µF at input
200
250
All WRA48 types when 10µF at input
105
150
VIN Nominal 24XX
8
VIN Nominal 48XX
16
◆
24V & 48V nominal input
◆
12V & 15V Output
◆
Power density 1.00W/cm3
◆
Remote on/off
Parameter
Conditions
◆
No electrolytic capacitors
Voltage set point accuracy
Low noise
Line regulation
With external input/output capacitors
Low line to high line with external
input/
output capacitors
Load regulation
Minimum load to rated load with
◆
Units
V
mA p-p
mW
INPUT CHARACTERISTICS
Min.
external input/output capacitors
MODEL SELECTION
①
②
③ ④
⑤
⑥
WR
WRA
A 24 12 Y LS -3W
Ripple
Typ.
Max.
±1
±5
%
0.05
0.2
%
0.2
0.5
%
15
30
mV rms
90
150
mV p-p
2.1
5.0
%
BW = 20Hz to 300kHz with external input/
Units
output capacitors
①Product Series ②Input Voltage
③Output Voltage ④Wide (2:1) Input Range
⑤Lengthened SIP10 Package Style
⑥ Rated Power
BW = DC to 20MHz with external input/
Ripple & noise
output capacitors
% voltage change on negative output
Cross regulation
when positive load varies from 12% to
50% with negative load fixed at 50%
PRODUCT OVERVIEW
The WRA-YLS-3W series is a range of high
performance miniature DC/DC converters having
regulated outputs over the wide temperature range of
–40°C to +85°C. The input voltage range is 2:1 and the
input to output isolation is 1kVDC. Continuous short circuit
protection, external control and extremely small SIP
packaging provide state of the art functionality. The use of
ceramic capacitors and a ceramic substrate, and SMD
construction, provide genuine high reliability. Nominal
input voltages of 24 and 48V with output voltages of 12
and 15V are available as standard with custom parts on
request. The plastic case is rated to UL 94V-0 with
encapsule to UL 94V-1.
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
Continuous
Lead temperature 1.5mm from case for 10 seconds
300℃
Minimum output load for specifcation3
25% of rated output
Control pin input current
15mA
Input voltage 24 types1
40V
Input voltage 48 types1
80V
Free air space
10mm MIN. around component
1. Absolute maximum value for 30 seconds. Prolonged operation may damage the product.
2. Measured at full load with external input/output capacitors. Refer to application note.
3. A lower load condition can be used but higher levels of output ripple may be experienced, this condition
may also cause the output voltage to exceed its specification transiently during power down when the
input voltage also falls below its rated minimum.
MICRODC RESERVES THE COPYRIGHT
http://www.microdc.cn
All specifications typical at TA=25°C, Nominal input voltage and rated output current unless otherwise specified.
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 4
WRA-YLS-3W Series
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
MIN.
TYP.
-40
85
Operation
-40
100
Storage
-50
130
Case temperature rise above ambient
Units
MAX.
Specification
12V & 15V output types @ 100% load
°C
36
MTTF (MEAN TIME TO FAILURE)
Part Number
MTTF
WRA2412YLS-3W
2077
WRA2415YLS-3W
2080
WRA4812YLS-3W
2090
WRA4815YLS-3W
2045
Conditions
Units
Calculated using MIL-HDBK 217F with
kHrs
Nominal input at full voltage (ground
benign) at 25°C.
GENERAL CHARACTERISTICS
Parameter
Control pin (CTRL) input current
Switching frequency
Conditions
Please refer to control pin application note
MIN.
TYP.
6
MAX.
Units
15
mA
Load causing lowest frequencies, 100% load VIN MIN.
100
125
150
Load causing highest frequencies, 25% load VIN MAX.
300
400
500
MIN.
TYP.
MAX.
kHz
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation test voltage
Flash tested for 1 second
Resistance
VISO = 1000VDC
Units
1000
VDC
1
GΩ
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
MICRODC WRA-YLS-3W series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals, such as the WRA-YLS-3W series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier
must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according
to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The WRA-YLS-3W series has an EI ferrite core, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 4
WRA-YLS-3W Series
APPLICATION NOTES
External capacitance
Although these converters will work without external capacitors, they are necessary
Value
in order to guarantee the full parametric performance over the full line and load
range. All parts have been tested and characterized using the following values and
CIN
COUT
10µF, 200V
47µF, 25V
test circuit.
Value
Control Pin
The WRA-YLS-3W converters have a shutdown feature which enables the user to put the converter into a low power state. The control pin connects directly to the base of an
internal transistor. If the pin is left open (high impedance), the converter will be ON (there is no allowed low state for this pin), but once a control voltage is applied with sufficient
drive current, the converter will be switched OFF. A suitable application
circuit is shown below.
D1 (eg 1N4001) is required to provide high impendence when the signal is
low. From the WRA-YLS-3W specification, the drive current to operate this
function is recommended to be 6mA, and hence the value of R1 can be
derived as follows:
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 3 of 4
WRA-YLS-3W Series
Cross Regulation
Load regulation is at its best when the positive and negative loads are balanced. When the loads are asymmetric, the negative output is not as tightly regulated as the positive output.
To meet ripple specification a total minimum load of 25% full load is required, however, the WRA-YLS-3W can be used with much lighter loading at the expense of increased ripple. A
small load is required on the negative output of 150mW to ensure the maximum negative output voltage is not exceeded.
Cross regulation is defined as change in the negative output voltage as a percentage of nominal as the positive output load is changed from 12.5% to 50% with the
negative load is fixed at 50% of full load.
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS
Pin
Function
1
-VIN
2
+VIN
3
CTRL
6
+VOUT
7
0V
8
N/A
9
-VOUT
Package weight: 6.5g
N/A - Not available for electrical Connection
All pins on a 0.1(2.54) pitch and within
±0.01(0.25) of true position.
Unless otherwise stated all dimensions in
inches(mm) ±0.01(0.25).
RoHS COMPLIANT INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature
of 300°C for 10 seconds.
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin
with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this
series are backward compatible with Sn/Pb soldering systems.
Microdc Professional Power Module,Inc.
Tel:0086-20-86000646
E-mail:[email protected]
Website:http://www.microdc.cn
REACH COMPLIANT INFORMATION
This series has proven that this product does not contain harmful chemicals, it also has
harmful chemical substances through the registration, inspection and approval.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 4 of 4