WRA-ZMDP10&WRB-ZMD P10 Series 10W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER SELECTION GUIDE Input Efficiency Order code FEATURES ◆ Wide (4:1) Input Range ◆ Short Circuit Protection(automatic recovery) ◆ 1500VDC Isolation ◆ Operating Temperature: -40℃~﹢85℃ Output Voltage(VDC) Current(mA) Voltage (%,Typ) Nominal Range Max* (VDC) Max. Min. WRA2403ZMDP10 24 9-36 40 ±3.3 ±1515 ±152 83 WRA2405ZMDP10 24 9-36 40 ±5 ±1000 ±100 84 WRA2412ZMDP10 24 9-36 40 ±12 ±416 ±42 81 WRA2415ZMDP10 24 9-36 40 ±15 ±333 ±33 83 WRB2403ZMDP10 24 9-36 40 3.3 3030 303 81 ◆ No heat sink required WRB2405ZMDP10 24 9-36 40 5 2000 200 79 ◆ No external component required WRB2412ZMDP10 24 9-36 40 12 833 83 81 ◆ Internal SMD required WRB2415ZMDP10 24 9-36 40 15 666 67 81 Metal shielding package WRA4812ZMDP10 48 18-72 80 ±12 ±416 ±42 85 MTBF>1000Khours WRA4815ZMDP10 48 18-72 80 ±15 ±333 ±33 83 WRB4812ZMDP10 48 18-72 80 12 833 83 85 WRB4815ZMDP10 48 18-72 80 15 666 67 83 ◆ ◆ MODEL SELECTION WRB①24②05③Z④M⑤D⑥P10⑦ *Input voltage can’t exceed this value,or will cause the permanent damage. ①Product Series ②Input Voltage ③Output Voltage ④Wide (4:1) Input Range ⑤Metal Shield ⑥DIP Package Style ⑦Rated Power 10W COMMON SPECIFICATIONS APPLICATIONS Parameter The WRA-ZMDP10&WRB-ZMDP10 Series are specially designed for applications where a wide range input voltage power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1 ) Where the voltage of the input power supply is wide range (Voltage range≤4:1); 2 ) Where isolation is necessary between input and output (Isolation voltage≤1500VDC); 3)Where the regulation of the Output voltage and the output ripple noise are demanded. http://www.microdc.cn Min. Typ. Storage humidity Max. Units 95 % Operating temperature -40 85 ℃ Storage temperature -55 125 ℃ 40 Temp. rise at full load Lead temperature ℃ 300 1.5mm from case for 10 seconds ℃ Cooling Free Air Convection Short circuit protection Continuous, Automatic recovery Case material Aluminum Alloy metal Isolation voltage Tested for1 minute and 1mA max 1500 VDC Isolation resistance Test at 500VDC 1000 MΩ Isolation Capacitance Input/output MTBF MICRODC R ESERVES THE COPYRIGHT Conditions Weight 1000 1000 pF K hours 23.5 Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 g page 1/3 WRA-ZMDP10&WRB-ZMD P10 Series TYPICAL CHARACTERISTICS TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Output power See below products program 1.0 Positive voltage accuracy Refer to recommended circuit Negative voltage accuracy Typ. Max. Units 10 W ±1 ±3 % Refer to recommended circuit ±3 ±5 % Load regulation Form 10% to 100% load ±0.5 ±1* % Line regulation Input voltage from low to high ±0.2 ±0.5 % Temperature drift (Vout) Refer to recommended circuit ±0.03 %/°C Ripple** 20MHz Bandwidth 20 50 mVp-p Noise** 20MHz Bandwidth 75 150 mVp-p Switching frequency 100% load, input voltage range 300 * Dual output models unbalanced load: ±5%. ** Test ripple and noise by “parallel cable” method. See detailed Testing of Power Converter section, application notes. KHz Temperature Derating Graph RECOMMENDED CIRCUIT Output Graph operation instructions at Case material APPLICATION NOTE Requirement on output load In order to ensure the product operate efficiently and reliably,in addition to a max load(namely full load), a minimum load is specified for this kind of DC/DC converter.Make sure the specified range of input voltage is not exceeded,the minimum output load no less than 10% load.If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly.If the actual output power is very small,please add an appropriate resistor as extra loading,or contact our company for other lower output power products. Recommended Circuit All the WRA_ZMDP10&WRB_ZMDP10 Series have been tested according to the following recommended testing circuit before leaving factory.This series should be tested under load(see Figure 1). If you want to further decrease the input/output ripple,you can increase capacitance properly or choose capacitors with low ESR.However,the capacitance of the output filter capacitor must be proper.If the capacitance is too big,a startup problem might arise.For every channel of output,provided the safe and reliable operation is ensured,the greatest capacitance of its filter capacitor sees (Table 1).General: Cin: 10μF-47μF Cout: 10μF/100mA CTRL Terminal When open or high impedance,the converter work well; When this pin is ‘high’; the converter shutdown; It should be note that the input current (Ic) should between 5-10mA, exceeding the maximum 20mA will cause permanence damage to the converter. The value of R Can be derived as follows : Output External Capacitor Table(Table 1) Input current While using unstable power source,please ensure the output voltage and ripple voltage do not exceed indexes of the converter.The preceding power source must be able to provide for converter sufficient starting current Ip(Figure 2). General:Ip≤1.6*Iin-max No parallel connection or plug and play http://www.microdc.cn Single Vout Cout Dual Vout Cout (VDC) (μF) (VDC) (μF) 5 680 ±5 680 12 470 ±12 330 15 330 ±15 220 Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 page 1/3 WRA-ZMDP10&WRB-ZMD P10 Series OUTLINE DIMENSIONS & FOOTPRINT DETAILS RECOMMENDED FOOTPRINT MECHANICAL DIMENSIONS Note: Unit:mm[inch] Pin section tolerances:±0.10mm[±0.004inch] General tolerances:±0.25mm[±0.010inch] RECOMMENDED FOOTPRINT Top view,grid:2.54mm[0.1inch] diameter:1.00mm[0.039inch] FOOTPRINT DETAILS TUBE OUTLINE DIMENSIONS Pin Single Dual 1 GND GND 2 Vin Vin 3 +Vo +Vo 4 NP 0V 5 0V -Vo NP:No Pin When the environment temperature is higher than 71℃, the product output power should be less then 60% of the rated power. No parallel connection or plug and play. Use dual output simultaneously,forbid pening output pin (0V) to use as single output. Note: 1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically. 2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed. 3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 4. In this datasheet, all the test methods of indications are based on corporate standards. 5. Only typical models listed, other models may be different, please contact our technical person for more details. http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 page 1/3