WRA-ZMDP10&WRB-ZMDP10 Series

WRA-ZMDP10&WRB-ZMD P10 Series
10W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER
SELECTION GUIDE
Input
Efficiency
Order code
FEATURES
◆
Wide (4:1) Input Range
◆
Short Circuit Protection(automatic recovery)
◆
1500VDC Isolation
◆
Operating Temperature: -40℃~﹢85℃
Output
Voltage(VDC)
Current(mA)
Voltage
(%,Typ)
Nominal
Range
Max*
(VDC)
Max.
Min.
WRA2403ZMDP10
24
9-36
40
±3.3
±1515
±152
83
WRA2405ZMDP10
24
9-36
40
±5
±1000
±100
84
WRA2412ZMDP10
24
9-36
40
±12
±416
±42
81
WRA2415ZMDP10
24
9-36
40
±15
±333
±33
83
WRB2403ZMDP10
24
9-36
40
3.3
3030
303
81
◆
No heat sink required
WRB2405ZMDP10
24
9-36
40
5
2000
200
79
◆
No external component required
WRB2412ZMDP10
24
9-36
40
12
833
83
81
◆
Internal SMD required
WRB2415ZMDP10
24
9-36
40
15
666
67
81
Metal shielding package
WRA4812ZMDP10
48
18-72
80
±12
±416
±42
85
MTBF>1000Khours
WRA4815ZMDP10
48
18-72
80
±15
±333
±33
83
WRB4812ZMDP10
48
18-72
80
12
833
83
85
WRB4815ZMDP10
48
18-72
80
15
666
67
83
◆
◆
MODEL SELECTION
WRB①24②05③Z④M⑤D⑥P10⑦
*Input voltage can’t exceed this value,or will cause the permanent damage.
①Product Series
②Input Voltage
③Output Voltage
④Wide (4:1) Input Range
⑤Metal Shield
⑥DIP Package Style
⑦Rated Power 10W
COMMON SPECIFICATIONS
APPLICATIONS
Parameter
The WRA-ZMDP10&WRB-ZMDP10 Series are
specially designed for applications where a
wide range input voltage power supplies are
isolated from the input power supply in a
distributed power supply system on a circuit
board.
These products apply to:
1 ) Where the voltage of the input power
supply is wide range (Voltage range≤4:1);
2 ) Where isolation is necessary between
input and output (Isolation voltage≤1500VDC);
3)Where the regulation of the Output voltage
and the output ripple noise are demanded.
http://www.microdc.cn
Min.
Typ.
Storage humidity
Max.
Units
95
%
Operating temperature
-40
85
℃
Storage temperature
-55
125
℃
40
Temp. rise at full load
Lead temperature
℃
300
1.5mm from case for 10 seconds
℃
Cooling
Free Air Convection
Short circuit protection
Continuous, Automatic recovery
Case material
Aluminum Alloy metal
Isolation voltage
Tested for1 minute and 1mA max
1500
VDC
Isolation resistance
Test at 500VDC
1000
MΩ
Isolation Capacitance
Input/output
MTBF
MICRODC R ESERVES THE COPYRIGHT
Conditions
Weight
1000
1000
pF
K hours
23.5
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
g
page 1/3
WRA-ZMDP10&WRB-ZMD P10 Series
TYPICAL CHARACTERISTICS
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Output power
See below products program
1.0
Positive voltage accuracy
Refer to recommended circuit
Negative voltage accuracy
Typ.
Max.
Units
10
W
±1
±3
%
Refer to recommended circuit
±3
±5
%
Load regulation
Form 10% to 100% load
±0.5
±1*
%
Line regulation
Input voltage from low to high
±0.2
±0.5
%
Temperature drift (Vout)
Refer to recommended circuit
±0.03
%/°C
Ripple**
20MHz Bandwidth
20
50
mVp-p
Noise**
20MHz Bandwidth
75
150
mVp-p
Switching frequency
100% load, input voltage range
300
* Dual output models unbalanced load: ±5%.
** Test ripple and noise by “parallel cable” method. See detailed
Testing of Power Converter section, application notes.
KHz
Temperature Derating Graph
RECOMMENDED CIRCUIT
Output Graph
operation instructions at
Case material
APPLICATION NOTE
Requirement on output load
In order to ensure the product operate efficiently and reliably,in addition to a
max load(namely full load), a minimum load is specified for this kind of
DC/DC converter.Make sure the specified range of input voltage is not
exceeded,the minimum output load no less than 10% load.If the actual load
is less than the specified minimum load, the output ripple may increase
sharply while its efficiency and reliability will reduce greatly.If the actual
output power is very small,please add an appropriate resistor as extra
loading,or contact our company for other lower output power products.
Recommended Circuit
All the WRA_ZMDP10&WRB_ZMDP10 Series have been tested
according to the following recommended testing circuit before leaving
factory.This series should be tested under load(see Figure 1).
If you want to further decrease the input/output ripple,you can increase
capacitance properly or choose capacitors with low ESR.However,the
capacitance of the output filter capacitor must be proper.If the capacitance
is too big,a startup problem might arise.For every channel of output,provided
the safe and reliable operation is ensured,the greatest capacitance of its
filter capacitor sees (Table 1).General:
Cin: 10μF-47μF
Cout: 10μF/100mA
CTRL Terminal
When open or high impedance,the converter work well; When this pin is
‘high’; the converter shutdown; It should be note that the input current (Ic)
should between 5-10mA, exceeding the maximum 20mA will cause
permanence damage to the converter.
The value of R Can be derived as follows :
Output External Capacitor Table(Table 1)
Input current
While using unstable power source,please ensure the output voltage and
ripple voltage do not exceed indexes of the converter.The preceding power
source must be able to provide for converter sufficient starting current
Ip(Figure 2).
General:Ip≤1.6*Iin-max
No parallel connection or plug and play
http://www.microdc.cn
Single Vout
Cout
Dual Vout
Cout
(VDC)
(μF)
(VDC)
(μF)
5
680
±5
680
12
470
±12
330
15
330
±15
220
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
page 1/3
WRA-ZMDP10&WRB-ZMD P10 Series
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
RECOMMENDED FOOTPRINT
MECHANICAL DIMENSIONS
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
RECOMMENDED FOOTPRINT
Top view,grid:2.54mm[0.1inch]
diameter:1.00mm[0.039inch]
FOOTPRINT DETAILS
TUBE OUTLINE DIMENSIONS
Pin
Single
Dual
1
GND
GND
2
Vin
Vin
3
+Vo
+Vo
4
NP
0V
5
0V
-Vo
NP:No Pin
When the environment temperature is higher than 71℃,
the product output power should be less then 60% of
the rated power.
No parallel connection or plug and play.
Use dual output simultaneously,forbid pening output
pin (0V) to use as single output.
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
5. Only typical models listed, other models may be different, please contact our technical person for more details.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
page 1/3