NHD‐0220D3Z‐FL‐GBW Serial Liquid Crystal Display Module NHD‐ 0220‐ D3Z‐ F‐ L‐ G‐ B‐ W‐ Newhaven Display 2 lines x 20 characters Model Transflective Yellow/Green LED Backlight STN‐ Gray 6:00 view Wide Temperature (‐20°C ~ +70°C) RoHS Compliant Newhaven Display International, Inc. 2511 Technology Drive, Suite 101 Elgin IL, 60124 Ph: 847‐844‐8795 Fax: 847‐844‐8796 www.newhavendisplay.com [email protected] [email protected] [1] Document Revision History Revision 0 1 2 3 4 5 Date 7/11/2007 12/15/2009 2/15/2010 5/16/2011 11/7/2011 4/9/2012 Description Initial Release User guide reformat Added in resistor image Mechanical Drawing Updated Pin description updated Electrical characteristics updated / User guide reformatted Functions and Features • • • • • • 2 lines x 20 characters Serial Interface: I2C, SPI or RS232 5V power supply 1/16 duty, 1/5 bias 5x8 pixels with cursor RoHS Compliant [2] Changed by ‐ CL MC TJ AK AK Mechanical Drawing NHD-0220D3Z-FL-GBW Pin Description Pin No. Symbol 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RX VSS VDD NC SPISS SDO SCK/SCL SDI/SDA VSS VDD NC NC NC NC External Connection MPU Power Supply Power Supply NC MPU NC MPU MPU Power Supply Power Suppy NC NC NC NC Function Description RS232 Serial input port Ground Power supply for logic (+5.0V) No Connect SPI Slave Select (NC in I2C mode) No Connect Serial Clock Serial Data In (SPI) / Serial Data (I2C) Ground Power Supply for logic (+5.0V) No Connect No Connect No Connect No Connect Recommended LCD connector: 2.54mm pitch pins (pins 1‐3 or pins 5‐10) Backlight connector: controlled by command Mates with: ‐ Jumper Communication Selection R1 Short Open Short Open R2 Short Short Open Open Protocol TEST SPI I2C RS232 Description Self‐test 100KHz max clock 100KHz max clock 5V, TTL signal [4] Electrical Characteristics Item Operating Temperature Range Storage Temperature Range Supply Voltage Supply Current (LCD + Backlight) Symbol Top Tst VDD IDD Supply for LCD (contrast) VDD‐V0 “H” Level input (Schmitt Trigger) “L” Level input (Schmitt Trigger) “H” Level output “L” Level output Condition Ta=25°C VDD=5.0V Ta=25°C Vih Vil Voh Vol Min. ‐20 ‐30 4.7 ‐ Typ. ‐ ‐ 5.0 220 Max. +70 +80 5.5 ‐ Unit ⁰C ⁰C V mA ‐ ‐ ‐ V 0.8VDD VSS ‐ ‐ ‐ ‐ ‐ ‐ VDD 0.2VDD ‐ ‐ V V V V Min. ‐ ‐ ‐ ‐ ‐ ‐ ‐ Typ. 10 60 45 45 3 100 150 Max. ‐ ‐ ‐ ‐ ‐ 150 200 Unit ⁰ ⁰ ⁰ ⁰ ‐ ms ms Optical Characteristics Item Viewing Angle – Top Viewing Angle – Bottom Viewing Angle – Left Viewing Angle – Right Contrast Ratio Response Time (rise) Response Time (fall) Symbol θ θ Ф Ф Cr Tr Tf Condition Cr ≥ 2 Cr ≥ 2 Cr ≥ 2 Cr ≥ 2 ‐ ‐ Built‐in LCD Controller: PIC 16F690 http://www.newhavendisplay.com/app_notes/PIC16F690.pdf [5] Communication Information This display uses a built‐in PIC 16F690 for serial communication. I2C protocol: To enter the I2C mode, place a jumper on R1. SDA and SDK have pull‐up resistors (10K Ohm) on R7 and R8. The default I2C address is 80 (50 hex). The I2C address can be changed to any 8‐bit value by command function, with the exception that the LSB (least significant bit) must always be ‘0’. Once the I2C address has been changed, it will be saved in the system memory, and it will revert back to the default address if either RS232 or SPI protocol is selected. The I2C interface is capable of receiving data at up to 100KHz clock rate. SPI protocol: To enter the SPI mode, place a jumper on R2. SPI mode has a normally high level idle clock. When Slave Select is LOW, data is sampled on the rising edge of the Clock. The SPI interface is capable of receiving data at up to 100KHz clock rate. RS232 protocol: To enter the RS232 mode, both R1 and R2 should be open. The RS232 signal must be 5V TTL compatible. Communication format is 8‐bit data, 1 Stop bit, no parity, no hand‐shaking. Default BAUD rate is 9600, and is changeable with a command function. Once the BAUD rate has been changed, it will be saved in the system memory, and it will revert back to the default address if either I2C or SPI protocol is selected. ASCII Text To display normal text, just enter its ASCII number. A number from 0x00 to 0x07 displays the user defined custom character, 0x20 to 0x7F displays the standard set of characters, 0xA0 to 0xFD display characters and symbols that are factory‐masked on the ST7066U controller. 0xFE is reserved. [6] Table of Commands Prefix Command 0xFE 0x41 0xFE 0x42 0xFE 0x45 0xFE 0x46 0xFE 0x47 0xFE 0x48 0xFE 0x49 0xFE 0x4A 0xFE 0x4B 0xFE 0x4C 0xFE 0x4E 0xFE 0x51 0xFE 0x52 0xFE 0x53 0xFE 0x54 0xFE 0x55 0xFE 0x56 0xFE 0x61 0xFE 0x62 0xFE 0x70 0xFE 0x71 0xFE 0x72 Parameter None None 1 Byte None None None None None None None None None 1 Byte 1 Byte 9 Byte None None 1 Byte 1 Byte None None None Description Display on Display off Set cursor Cursor home Underline cursor on Underline cursor off Move cursor left one place Move cursor right one place Blinking cursor on Blinking cursor off Backspace Clear screen Set contrast Set backlight brightness Load custom character Move display one place to the left Move display one place to the right Change RS232 BAUD rate 232 Change I2C address Display firmware version number Display RS232 BAUD rate Display I2C address Changing the I2C Slave Address Syntax hexadecimal 0xFE 0x62 [addr] Parameter Parameter Length Description 2 [addr] 1 byte New I C address, 0x00 – 0xFE The LSB is always ‘0’. Description This command sets the I2C address. The address must be an even number (LSB = 0). The address change requires 20 microseconds to take effect; therefore, the subsequent input must have an appropriate delay. The default I2C address can be restored if SPI or RS232 is selected as the communication mode. Default: 0x50 [7] Changing BAUD Rate Syntax hexadecimal 0xFE 0x61 [baud] Parameter Parameter Length Description [baud] 1 byte New RS232 BAUD Rate, 1 ‐ 8 Description This command sets the RS232 BAUD rate. The single byte parameter selects the desired BAUD rate as in the table below. The new BAUD rate requires 20 microseconds to take effect; therefore, the subsequent input must have an appropriate delay. The default BAUD rate can be restored if I2C or SPI is selected as the communication mode. Illegal parameter input will be discarded. Parameter BAUD 1 300 2 1200 3 2400 4 9600 5 14400 6 19.2K 7 57.6K 8 115.2K Default: 9600 BAUD Turn On Display Syntax hexadecimal 0xFE 0x41 Parameter Parameter Length Description None None Turn on LCD screen Description This command turns on the LCD display screen. The display text is not altered. Default: LCD screen is on Turn Off Display Syntax hexadecimal 0xFE 0x42 Parameter Parameter Length Description None None Turn off LCD screen Description This command turns off the LCD display screen. The display text is not altered. Default: LCD screen is on [8] Set Cursor Position Syntax hexadecimal 0xFE 0x45 [pos] Parameter Parameter Length Description [pos] 1 byte Put cursor at location specified by [pos], 0x00 to 0x67 Description This command moves the cursor to a specified location where the next character will be displayed. The typical cursor position for a 4‐line display is show below; a cursor position outside these ranges will not be viewable. Column 1 Column 20 Line 1 0x00 0x13 Line 2 0x40 0x53 Default: After a reset, the cursor is on position 0x00 Home Cursor Syntax hexadecimal 0xFE 0x46 Parameter Parameter Length Description None None Position cursor at line 1 column 1 Description This command moves the cursor to line 1, column 1 of the LCD screen. The display text is not altered. Default: None Turn On Underline Cursor Syntax hexadecimal 0xFE 0x47 Parameter Parameter Length Description None None Turn on underline cursor Description This command turns on the underline cursor. Default: Underline cursor is off Turn Off Underline Cursor Syntax hexadecimal 0xFE 0x48 Parameter Parameter Length Description None None Turn off underline cursor Description This command turns off the underline cursor. Default: Underline cursor is off [9] Move Cursor Left One Space Syntax hexadecimal 0xFE 0x49 Parameter Parameter Length Description None None Move cursor left 1 space Description This command moves the cursor position left 1 space whether the cursor is turned on or not. The displayed character is not altered. Default: None Move Cursor Right One Space Syntax hexadecimal 0xFE 0x4A Parameter Parameter Length Description None None Move cursor right 1 space Description This command moves the cursor position left 1 space whether the cursor is turned on or not. The displayed character is not altered. Default: None Turn On Blinking Cursor Syntax hexadecimal 0xFE 0x4B Parameter Parameter Length Description None None Turn on the blinking cursor Description This command turns on the blinking cursor. Default: The blinking cursor is off Turn Off Blinking Cursor Syntax hexadecimal 0xFE 0x4C Parameter Parameter Length Description None None Turn off the blinking cursor Description This command turns off the blinking cursor. Default: The blinking cursor is off [10] Back Space Syntax Parameter Description Clear Screen Syntax Parameter Description hexadecimal 0xFE 0x4E Parameter Length Description None None Move cursor back one space, delete last character. This command is destructive backspace. The cursor is moved back one space and the character on the cursor is deleted. Default: None hexadecimal 0xFE 0x51 Parameter Length Description None None Clear LCD and move cursor to line 1 column 1. This command clears the entire display and place the cursor at line 1 column 1. Default: None Set Display Contrast Syntax hexadecimal 0xFE 0x52 [contrast] Parameter Parameter Length Description [contrast] 1 byte Set the display contrast, value between 1 and 50 Description This command sets the display contrast. The contrast setting can be between 1 and 50, where 50 is the highest contrast. Default: 40 Set Backlight Brightness Syntax hexadecimal 0xFE 0x53 [brightness] Parameter Parameter Length Description [brightness] 1 byte Set the backlight brightness level, value between 1 and 8 Description This command sets the backlight brightness level. The value can be between 1 and 8. Default: 1 [11] Load Custom Characters Syntax hexadecimal 0xFE 0x54 [addr] [d0 …d7] Parameter Parameter Length Description [addr] 1 byte Custom character address, 0 – 7 [D0...D7] 8 bytes Custom character pattern bit map Description There is space for eight user‐defined custom characters. This command loads the custom character into one of the eight locations. The custom character pattern is bit mapped into 8 data bytes. The bit map for Spanish character ‘¿’ is shown in table below. To display the custom character, user has to enter the address of the character (0 to 8). Default: None Bit 7 6 5 4 3 2 1 0 Hex Byte 1 0 0 0 0 0 1 0 0 0x04 Byte 2 0 0 0 0 0 0 0 0 0x00 Byte 3 0 0 0 0 0 1 0 0 0x04 Byte 4 0 0 0 0 1 0 0 0 0x08 Byte 5 0 0 0 1 0 0 0 0 0x10 Byte 6 0 0 0 1 0 0 0 1 0x11 Byte 7 0 0 0 0 1 1 1 0 0x0E Byte 8 0 0 0 0 0 0 0 0 0x00 Shift Display to the Left Syntax hexadecimal 0xFE 0x55 Parameter Parameter Length Description None None Shift the LCD screen to the left 1 space. Description This command shifts the display to the left 1 space. The cursor position also moves with the display, and the display data is not altered. Default: None Shift Display to the Right Syntax hexadecimal 0xFE 0x56 Parameter Parameter Length Description None None Shift the LCD screen to the right 1 space. Description This command shifts the display to the right 1 space. The cursor position also moves with the display, and the display data is not altered. Default: None [12] Display Firmware Version Number Syntax hexadecimal 0xFE 0x70 Parameter Parameter Length Description None None Display the firmware version number. Description This command displays the firmware version. Default: None Display RS232 Baud Rate Syntax hexadecimal 0xFE 0x71 Parameter Parameter Length Description None None Display Baud Rate Description This command displays the RS232 BAUD rate. Default: None Display I2C Address Syntax hexadecimal 0xFE 0x72 Parameter Parameter Length Description 2 None None Display I C Address Description This command displays the current I2C slave address. Default: None Example Initialization Program See program code at http://www.newhavendisplay.com/app_notes/Serial_LCD.txt [13] Built‐in Font Table [14] Quality Information Test Item Content of Test High Temperature storage Endurance test applying the high storage temperature for a long time. Endurance test applying the low storage temperature for a long time. Endurance test applying the electric stress (voltage & current) and the high thermal stress for a long time. Endurance test applying the electric stress (voltage & current) and the low thermal stress for a long time. Endurance test applying the electric stress (voltage & current) and the high thermal with high humidity stress for a long time. Endurance test applying the electric stress (voltage & current) during a cycle of low and high thermal stress. Endurance test applying vibration to simulate transportation and use. Low Temperature storage High Temperature Operation Low Temperature Operation High Temperature / Humidity Operation Thermal Shock resistance Vibration test Static electricity test Test Condition Endurance test applying electric static discharge. 2 ‐30⁰C , 48hrs 1,2 +70⁰C 48hrs 2 ‐20⁰C , 48hrs 1,2 +40⁰C , 90% RH , 48hrs 1,2 0⁰C,30min ‐> +25⁰C,5min ‐> +50⁰C,30min = 1 cycle 10 cycles 10‐55Hz , 15mm amplitude. 60 sec in each of 3 directions X,Y,Z For 15 minutes VS=800V, RS=1.5kΩ, CS=100pF One time Note 1: No condensation to be observed. Note 2: Conducted after 4 hours of storage at 25⁰C, 0%RH. Note 3: Test performed on product itself, not inside a container. Precautions for using LCDs/LCMs See Precautions at www.newhavendisplay.com/specs/precautions.pdf Warranty Information and Terms & Conditions http://www.newhavendisplay.com/index.php?main_page=terms [15] Note +80⁰C , 48hrs 3