250W Power Inverter

TM
250 WATT
POWER INVERTER
MODEL: S LX-250- DRV
PLUG YOUR INVERTER INTO THE
LIGHTER SOCKET OR CLAMP ON TO
YOUR VEHICLE BATTERY TO CONNECT.
THEN PLUG YOUR DEVICE INTO THE
INVERTER FOR POWER.
SPECIFICATIONS
INPUT
Charge laptops, smart phones, tablets, camera
batteries and MP3 players. Make vacations with
the kids more relaxing as they watch movies and
play games without the fear of batteries going
dead. Run a mobile office - print receipts, make
copies, send emails… and never miss a call from
your boss while you’re playing hooky.
BATTERY SYSTEM VOLTAGE
OUTPUT
HOUSEHOLD POWER
FROM A 12V B ATTERY
OUTLETS
GENERAL
SAFETY
- Light weight, compact, highly portable
- Easy to install and operate
- 2.1 Amp USB Port (compatible with all new
release smart phones)
- Load controlled cooling fan
- Cool surface technology
- Soft start technology
- Low battery input alarm
- Universal protection circuit – thermal, battery,
overload, short circuit & earth fault
- Safety certified to UL standards
- 2 YEAR W ARR ANTY
PR O TECT IO NS
DESIGN FEATURES
12 VDC
NOMINAL INPUT VOLTAGE
12.5 VDC
INPUT VOLTAGE RANGE
> 10.8 VDC to < 15.4 VDC
INPUT CURR ENT AT CONTINUOUS POWE R
22.3A to 24.2A
INPUT CURR ENT AT NO LOAD
0.2A to 0.3A
OUTPUT VOLTAGE WAVE FORM
Modified Sine Wave
OUTPUT VOLTAGE (FR EQUENCY)
115VAC + 10% / -2%; 60 Hz ± 5%
OUTPUT POWE R, CONTINUOUS (RES ISTIVE LOAD)
250W
OUTPUT POWE R, SURGE (<1 SEC., RES ISTIVE LOAD)
500W
PEAK E FF ICIENCY (AT 50% OF CONTINUOUS POWE R)
90%
USB CHARGING PORT
USB 3.0, Connector Type “A”: 5 VDC, 2.1A
LOW INPUT VOLTAGE ALARM
10.8 VDC ± 0.3 VDC
LOW INPUT VOLTAGE SHUTDOWN
10.5 VDC ± 0.3 VDC
HIGH INPUT VOLTAGE SHUTDOWN
15.4 VDC ± 0.2 VDC
OVERLOAD AND GROUND FAULT SHUT DOWN
Yes. Latches in shutdown condition. Manual
reset: Switch OFF the ON/ OFF Switch, wait 3
mins & Switch ON again.
OVER TEMPE RATURE SHUTDOWN
Yes. Auto reset on cooling down.
COOLING FAN
Load controlled: Switches ON at 8W to 12W
INPUT FUSE: 32V, AUTOMOTIVE TYPE ATC (INSIDE
THE UNIT, NOT USER ACCESSIBLE )
30A
DC INPUT
M4 Thumb Screw
AC OUTPUT
One NEMA5-15 R Outlet
OPERATING TEMPE RATURE RANGE
0°C to 25°C / 32°F to 77°F at 100% loading;
26°C to 35°C / 78.8°F to 95°F at 80% loading
OPERATING HUMIDITY
< 80%;Non-condensing
NEUTRAL TO CHASSIS B ONDING
No. Neutral of the NEMA5-15 R AC Outlet is
isolated from the chassis
DIMENSIONS (W x D x H)
114.4 x 150 x 46 mm
4.5 x 5.9 x 1.8 in
WEIGHT
0.42 kg / 0.92 lb
DC INPUT CABLES INCLUDED
AWG#16 Cable with 12V power plug (12V plug
contains replaceable 250V, 8A fuse - Bussmann
Type AGC-8); AW G#14 Cable with battery clamps
Safety Compliance
Conforms to UL S TD 458
NOTE: Specifications are subject to change without notice
12002-SLX-250-D RV-1113