F:\\\271\346\270\361\312\351\\00 AC-DC Converter\\AC-DC

Single Output
Switching Power Supply
NE-240 Series, 240Watt
FEATURES:
Input voltage range AC100-120V/200-240V
High reliability
Built-in EMI filter
Short circuit, over current, over voltage protections
Cooling by free air convection
100% burn-in test
With LED power indicator
3 year warranty
Output voltage
(Vdc)
Output current
(A)
Efficiency
Typ.
NE240-3
3.3
48
75%
NE240-5
5
48
78%
9
26.7
81%
12
20
83%
15
16
85%
NE240-24
24
10
86%
NE240-48
48
5
86%
Model
NE240-9
NE240-12
NE240-15
Input voltage
(Vac)
100-120/
200-240
Note:100-120AC/200-240VAC (88-132VAC/176-264VAC) or 248-370VDC, 50/60HZ User-Selectable.
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
88
Input voltage
Vin
--
176
240
Input frequency
Inrush current
Input current
www.pairuigroup.com
Fline
Iinrush
Iin
Typ.
---
Max.
Units
132
Vac
264
Vac
370
Vdc
--
47
--
63
Hz
Cold start, Vin =115Vac, full load
--
20
--
A
Cold start, Vin =230Vac, full load
--
40
--
A
Full load, Vin =115Vac
--
5.5
--
A
Full load, Vin =230Vac
--
2
--
A
Page: 1 / 3
Date: 02/27/2014
Single Output
Switching Power Supply
NE-240 Series, 240Watt
ELECTRICAL
Output
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Line regulation
Iout-line
--
--
1
--
%
Load regulation
Iout-load
Vout from min. to max.
--
1
--
%
--
Full load, Vin =115Vac
--
15
--
ms
Ton_delay
Cold start, power on
--
--
1.5
S
--
--
--
120
240
mV
Hold-on time
Turn-on delay time
Ripple
Protection
Over current
Type:110-150%; Hiccup mode, it will recover automatically after fault condition is removed
Short circuit
Hiccup mode, it will recover automatically after fault condition is removed
Over voltage
Type:110-150%; Hiccup mode, it will recover automatically after fault condition is removed
Environment
Storage
Ambient operating
temperature
Operating relative
humidity
MTBF
Tstorage
Ta
Humidity: 5% RH to 95% RH
Startup at rated voltage
(Required Derating)
Ha
TMTBF
Non condensing
Full load, 230Vac input,
℃
25
ambient temperature
Dimension(LxWxH)
-40
--
+85
℃
-25
--
+70
℃
10
--
95
%
--
--
200
kHrs
201 x 98 x 41mm
Safety / EMC
Withstand voltage
I/P-O/P: 3KVac
I/P-FG: 2KVac
Safety standards
UL, C-UL, CE, CB
EMC
EN55011/EN55022-B
O/P-FG: 0.5KVac
FCC-B
Notes: 1. Rated Load and Rated Input Voltage,Ta=25℃;
2. Ripple &Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf
& 47uF parallel capacitor.
www.pairuigroup.com
Page: 2 / 3
Date: 02/27/2014
Single Output
Switching Power Supply
NE-240 Series, 240Watt
MECHANICAL
www.pairuigroup.com
Page: 3 / 3
Date: 02/27/2014