Constant voltage LED Drivers For outdoor use LFU-60V Series, 60Watt FEATURES: Constant voltage output Universal AC input range Active power factor correction Short circuit, and over voltage protections Designed to worldwide safety standards for lighting Cooling by free air convection Class , no FG 100% burn-in test 2 year warranty Ⅱ Model Input voltage (Vac) Output voltage (Vdc) Output current (A) Output power (W) Min. Max. 5 0 8 40 12 0 5 60 15 0 4 60 24 0 2.5 60 LFU60-V36 36 0 1.67 60 LFU60-V48 48 0 1.25 60 LFU60-V5 LFU60-V12 LFU60-V15 LFU60-V24 90-264 ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin -- 90 -- 264 Vac Input frequency Fline -- 47 -- 63 Hz Full load, Vin =115Vac -- -- 0.75 A Full load, Vin =230Vac -- -- 0.36 A Input current Iin Power factor PF 70%~100% load, Vin =230Vac -- 0.9 -- PF Inrush current Iinrush Cold start, Vin =230Vac -- 35 -- A η Full voltage, full load -- 90 -- % Ton_delay Cold start, power on -- 1000 -- ms Efficiency Turn-on delay time www.pairuigroup.com Page: 1/3 Date: 05/22/2014 Constant voltage LED Drivers For outdoor use LFU-60V Series, 60Watt ELECTRICAL Output Parameters Test Conditions / Comment Min. Typ. Max. Units LFU60-V5 0 -- 8 A LFU60-V12 0 -- 5 A LFU60-V15 0 -- 4 A LFU60-V24 0 -- 2.5 A LFU60-V36 0 -- 1.67 A LFU60-V48 0 -- 1.25 A LFU60-V5 -- 5 -- V LFU60-V12 -- 12 -- V LFU60-V15 -- 15 -- V LFU60-V24 -- 24 -- V LFU60-V36 -- 36 -- V LFU60-V48 -- 48 -- V -- -- -- ±5 -- % Line regulation Iout-line -- -- ±1.0 -- % Load regulation Iout-load -- -- ±2.0 -- % -- -- -- 20 -- % Output current Output voltage Output voltage accuracy Ripple Symbols Iout Vout Protection Overvoltage Typical:110-150%. Short circuit Hiccup mode, it will recover automatically after fault condition is removed Environment Storage Ambient operating temperature Operating relative humidity MTBF Tstorage Ta Humidity: 5% RH to 95% RH Startup at rated voltage (required Derating) Ha TMTBF Non condensing Full load, 220Vac input, ℃ 25 ambient temperature Dimension(LxWxH) www.pairuigroup.com -40 -- +80 ℃ -25 -- +50 ℃ 10 -- 95 % 400 -- -- kHrs 162.5x42.5x32mm Page: 2/3 Date: 05/22/2014 Constant voltage LED Drivers For outdoor use LFU-60V Series, 60Watt ELECTRICAL Safety / EMC Safety standards UL8750, EN61347-1, EN61347-2-13 EMC EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547 ℃ Notes: 1.Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and Vin = 230Vac, rated load. 2.Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor; MECHANICAL Unit: mm RECOMMENDED INSTALLATION www.pairuigroup.com Page: 3/3 Date: 05/22/2014