DNV-3 - Pairui

DC-DC Converter
DIP-Package
DNV-3 SERIES, 3WATT, 2:1 INPUT RANGE
FEATURES:
1500Vdc isolation voltage
Metal/Plastic case with low ripple and noise
Short circuit and input under voltage protection
Operating temperature range -40
3 year warranty
℃
to +85
Output voltage
(Vdc)
Output current
(mA)
Efficiency
Typ.
DNV3-0511
5
600
80%
DNV3-0512
12
250
82%
DNV3-0514
15
200
82%
24
125
82%
±5
300
80%
DNV3-0522
±12
125
82%
DNV3-0523
±15
100
82%
DNV3-0524
±24
60
82%
DNV3-1211
5
600
80%
DNV3-1212
12
250
82%
DNV3-1214
15
200
82%
24
125
82%
DNV3-1221
±5
300
80%
DNV3-1222
±12
125
82%
DNV3-1223
±15
100
82%
DNV3-1224
±24
60
82%
DNV3-2411
5
600
80%
DNV3-2412
12
250
82%
DNV3-2414
15
200
82%
24
125
82%
±5
300
80%
DNV3-2422
±12
125
82%
DNV3-2423
±15
100
82%
DNV3-2424
±24
60
82%
DNV3-4811
5
600
80%
12
250
82%
15
200
82%
24
125
82%
Model
DNV3-0513
DNV3-0521
DNV3-1213
DNV3-2413
DNV3-2421
DNV3-4812
DNV3-4814
DNV3-4813
www.pairuigroup.com
Input voltage
(Vdc)
℃
5(4.5~9)
12(9~18)
24(18~36)
48(36~72)
Page: 1 / 4
Date: 12/08/2014
*Subject to change without notice
DC-DC Converter
DIP-Package
DNV-3 SERIES, 3WATT, 2:1 INPUT RANGE
Model
Input voltage
(Vdc)
Output voltage
(Vdc)
Output current
(mA)
Efficiency
Typ.
±5
300
80%
±12
125
82%
±15
100
82%
±24
60
82%
DNV3-4821
DNV3-4822
DNV3-4823
48(36~72)
DNV3-4824
Notes: other input and output models may available on request.
Above models are default to plastic case, you may request for the models with metal case, plus “M” in the suffix.
ELECTRICAL
Output voltage accuracy
---
Vo1, Vo2 : ±1.0%, ±3.0%
Line regulation
Nominal Load, full voltage
Vo1, Vo2 : ±0.2%, ±1.5%
Load regulation
20% ~ 100% full load
Vo1, Vo2 : ±0.5%, ±4.0%
5%-50%-75% load capability
∆Vo1/∆t : ±4.0%/500μs
Dynamic response
(transient/recovery time)
Vo≤5.0V, ≤50mVp-p
Ripple and noise
20MHz BM, full load
Operating frequency
Typical value
330KHz max.
Turn-on delay time
Typical value
≤200ms
Isolation voltage
Input to output
1500Vdc
(<0.5mA/min)
Input to case
Operating temperature range
---
Storage temperature range
---
℃ to +85℃
-55℃ to +125℃
Short circuit protection
---
Auto-recovery
Input under voltage protection
Other, ≤100mVp-p
500Vdc
-40
When input voltage is lower than the
low terminal input voltage
Relative humidity
---
MTBF
Bellcore TR-332, 25
Weight
---
Auto-recovery
10%-90%
℃
200KHrs
16g
Notes: All the parameters are measured at 25℃ ambient temperature, humidity < 75%, nominal input voltage,
full load and after warm-up, unless otherwise specified.
www.pairuigroup.com
Page: 2 / 4
Date: 12/08/2014
*Subject to change without notice
DC-DC Converter
DIP-Package
DNV-3 SERIES, 3WATT, 2:1 INPUT RANGE
MECHANICAL
CONNECTION
PIN #
SINGLE
DUAL
2
-Vin
-Vin
3
-Vin
-Vin
9
NC
COM
10
No Pin
No Pin
11
NC
-Vo2
14
+Vo
+Vo1
15
No Pin
No Pin
16
GND
COM
22
+Vin
+Vin
23
+Vin
+Vin
Note:
* Unit is mm(inch).
TEMPERATURE PROFILE
www.pairuigroup.com
Page: 3 / 4
Date: 12/08/2014
*Subject to change without notice
DC-DC Converter
DIP-Package
DNV-3 SERIES, 3WATT, 2:1 INPUT RANGE
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
FUSE: depends on the actual input current;
TVS: depends on the actual input voltage;
Recommended capacitor: C1,C2,C5,C8, about 0.1uF; C6: 22uF-100uF; C7, C9: 10uF/10mA.
www.pairuigroup.com
Page: 4 / 4
Date: 12/08/2014
*Subject to change without notice