DC-DC Converter DIP-Package DNV-3 SERIES, 3WATT, 2:1 INPUT RANGE FEATURES: 1500Vdc isolation voltage Metal/Plastic case with low ripple and noise Short circuit and input under voltage protection Operating temperature range -40 3 year warranty ℃ to +85 Output voltage (Vdc) Output current (mA) Efficiency Typ. DNV3-0511 5 600 80% DNV3-0512 12 250 82% DNV3-0514 15 200 82% 24 125 82% ±5 300 80% DNV3-0522 ±12 125 82% DNV3-0523 ±15 100 82% DNV3-0524 ±24 60 82% DNV3-1211 5 600 80% DNV3-1212 12 250 82% DNV3-1214 15 200 82% 24 125 82% DNV3-1221 ±5 300 80% DNV3-1222 ±12 125 82% DNV3-1223 ±15 100 82% DNV3-1224 ±24 60 82% DNV3-2411 5 600 80% DNV3-2412 12 250 82% DNV3-2414 15 200 82% 24 125 82% ±5 300 80% DNV3-2422 ±12 125 82% DNV3-2423 ±15 100 82% DNV3-2424 ±24 60 82% DNV3-4811 5 600 80% 12 250 82% 15 200 82% 24 125 82% Model DNV3-0513 DNV3-0521 DNV3-1213 DNV3-2413 DNV3-2421 DNV3-4812 DNV3-4814 DNV3-4813 www.pairuigroup.com Input voltage (Vdc) ℃ 5(4.5~9) 12(9~18) 24(18~36) 48(36~72) Page: 1 / 4 Date: 12/08/2014 *Subject to change without notice DC-DC Converter DIP-Package DNV-3 SERIES, 3WATT, 2:1 INPUT RANGE Model Input voltage (Vdc) Output voltage (Vdc) Output current (mA) Efficiency Typ. ±5 300 80% ±12 125 82% ±15 100 82% ±24 60 82% DNV3-4821 DNV3-4822 DNV3-4823 48(36~72) DNV3-4824 Notes: other input and output models may available on request. Above models are default to plastic case, you may request for the models with metal case, plus “M” in the suffix. ELECTRICAL Output voltage accuracy --- Vo1, Vo2 : ±1.0%, ±3.0% Line regulation Nominal Load, full voltage Vo1, Vo2 : ±0.2%, ±1.5% Load regulation 20% ~ 100% full load Vo1, Vo2 : ±0.5%, ±4.0% 5%-50%-75% load capability ∆Vo1/∆t : ±4.0%/500μs Dynamic response (transient/recovery time) Vo≤5.0V, ≤50mVp-p Ripple and noise 20MHz BM, full load Operating frequency Typical value 330KHz max. Turn-on delay time Typical value ≤200ms Isolation voltage Input to output 1500Vdc (<0.5mA/min) Input to case Operating temperature range --- Storage temperature range --- ℃ to +85℃ -55℃ to +125℃ Short circuit protection --- Auto-recovery Input under voltage protection Other, ≤100mVp-p 500Vdc -40 When input voltage is lower than the low terminal input voltage Relative humidity --- MTBF Bellcore TR-332, 25 Weight --- Auto-recovery 10%-90% ℃ 200KHrs 16g Notes: All the parameters are measured at 25℃ ambient temperature, humidity < 75%, nominal input voltage, full load and after warm-up, unless otherwise specified. www.pairuigroup.com Page: 2 / 4 Date: 12/08/2014 *Subject to change without notice DC-DC Converter DIP-Package DNV-3 SERIES, 3WATT, 2:1 INPUT RANGE MECHANICAL CONNECTION PIN # SINGLE DUAL 2 -Vin -Vin 3 -Vin -Vin 9 NC COM 10 No Pin No Pin 11 NC -Vo2 14 +Vo +Vo1 15 No Pin No Pin 16 GND COM 22 +Vin +Vin 23 +Vin +Vin Note: * Unit is mm(inch). TEMPERATURE PROFILE www.pairuigroup.com Page: 3 / 4 Date: 12/08/2014 *Subject to change without notice DC-DC Converter DIP-Package DNV-3 SERIES, 3WATT, 2:1 INPUT RANGE NOTES RECOMMENDED TEST AND APPLICATION CIRCUIT FUSE: depends on the actual input current; TVS: depends on the actual input voltage; Recommended capacitor: C1,C2,C5,C8, about 0.1uF; C6: 22uF-100uF; C7, C9: 10uF/10mA. www.pairuigroup.com Page: 4 / 4 Date: 12/08/2014 *Subject to change without notice