Switching Power Supply Single Output NF-600 Series, 600Watt FEATURES: Input voltage range 100-240VAC High reliability High power factor(Built-in PFC Circuit) Built-in EMI filter Short circuit, over current, over voltage protections Cooling by fan With LED power indicator 100% burn-in test 4 year warranty Output voltage (Vdc) Output current (A) Efficiency Typ. NF600-3 3.3 120 72% NF600-5 5 120 77% NF600-9 9 67 79% 12 53 82% NF600-15 15 43 82% NF600-24 24 27 84% NF600-48 48 13 83% Model NF600-12 Input voltage (Vac) 100-240 ELECTRICAL Input Parameters Symbols Test Conditions / Comment Input voltage Vin -- Input frequency Fline Inrush current Power factor Input current www.pairuigroup.com Min. Typ. Max. Units 85 -- 264 Vac 125 -- 370 Vdc -- 47 -- 63 Hz Cold start, Vin =115Vac,full load -- 20 -- A Cold start, Vin =230Vac,full load -- 40 -- A Full voltage ,full load 0.95 -- 0.98 PF Full load, Vin =115Vac -- 8.2 -- A Full load, Vin =230Vac -- 4.1 -- A Iinrush PF Iin Page: 1 / 3 Date: 07/17/2015 *Subject to change without notice Switching Power Supply Single Output NF-600 Series, 600Watt ELECTRICAL Output Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Line regulation Vout-line Vin from 100 Vac To 240 Vac -- 1 -- % Load regulation Vout-load Iout from min. To max. -- 1 -- % Hold-on time Ton_hold Full load, Vin =115Vac -- 20 -- ms Turn-on rise time Ton_rise Cold start, power on -- -- 500 mS Ripple & noise Vripple -- -- 120 250 mVp-p Protection Over current Type: works at over 105%; it will recover automatically after fault condition is removed Short circuit Hiccup mode, it will recover automatically after fault condition is removed Over voltage Type: 110-150%; Locked mode, it will recover automatically after turn off the power Environment Storage Ambient operating temperature Operating relative humidity MTBF Tstorage Ta Humidity: 20% RH to 90% RH Startup at rated voltage (Required Derating) Ha TMTBF Non condensing Full load, 230Vac input, ℃ 25 ambient temperature Dimension(LxWxH) -20 -- +75 ℃ -10 -- +70 ℃ 20 -- 90 % -- -- 200 kHrs 190 x 120 x 61mm Safety / EMC Withstand voltage I/P-O/P: 3KVac Safety standards UL, C-UL, CE, CB EMC EN55022-B THD IEC61000-3-2 I/P-FG: 2KVac O/P-FG: 0.5KVac Notes: 1. Rated Load and Rated Input Voltage,Ta=25℃; 2. Ripple &Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uF parallel capacitor. www.pairuigroup.com Page: 2 / 3 Date: 07/17/2015 *Subject to change without notice Switching Power Supply Single Output NF-600 Series, 600Watt MECHANICAL www.pairuigroup.com Page: 3 / 3 Date: 07/17/2015 *Subject to change without notice