DAM-2H - Pairui

DC-DC Converter
DIP-Package
DAM-2H SERIES, 2WATT, 6KVDC, ISOLATED, UNREGULATED
FEATURES:
6000Vdc isolation voltage
Single and dual output models
High efficiency, and low ripple & noise
Operating temperature range -40
3 year warranty
Model
Input voltage
(Vdc)
℃
to +85
℃
Output voltage
(Vdc)
Output current
(mA)
Min.
Max.
Efficiency
Typ.
DAM2-0511H
5
40
400
74%
DAM2-0512H
9
22.2
222
76%
DAM2-0513H
12
16.7
167
76%
15
13.3
133
77%
20
200
75%
11.1
111
76%
8.3
83
76%
6.7
67
76%
DAM2-0514H
DAM2-0524H
±5
±9
±12
±15
DAM2-1211H
5
40
400
75%
DAM2-1212H
9
22.2
222
77%
DAM2-1213H
12
16.7
167
75%
15
13.3
133
82%
20
200
73%
11.1
111
72%
8.3
83
79%
6.7
67
80%
5
40
400
75%
9
22.2
222
77%
12
16.7
167
78%
15
13.3
133
81%
20
200
75%
11.1
111
78%
8.3
83
79%
6.7
67
79%
DAM2-0521H
5(4.5~5.5)
DAM2-0522H
DAM2-0523H
DAM2-1214H
DAM2-1221H
12(10.8~13.2)
DAM2-1222H
DAM2-1223H
DAM2-1224H
DAM2-2411H
DAM2-2412H
DAM2-2413H
DAM2-2414H
DAM2-2421H
DAM2-2422H
DAM2-2423H
DAM2-2424H
24(21.6~26.4)
±5
±9
±12
±15
±5
±9
±12
±15
Notes: Other input and output models may available on request.
www.pairuigroup.com
Page: 1/4
Date: 07/20/2015
* Subject to change without prior notice
DC-DC Converter
DIP-Package
DAM-2H SERIES, 2WATT, 6KVDC, ISOLATED, UNREGULATED
ELECTRICAL
Line regulation
---
1.5% max.
Load regulation
10% ~ 100% full load
Isolation voltage
Leakage current < 1mA/1min.
6000Vdc min.
Isolation resistance
Test at 500VDC
1000m
Switching frequency
---
Ripple & noise
Bend width 20MHz
Temperature coefficient
Rated load
Operating temperature range
---
Storage temperature range
---
±0.03%/℃
-40℃ to +85℃
-55℃ to +125℃
Short circuit protection
---
Continuours, auto recovery
MTBF
---
3500KHrs
Weight
---
8.2g
15% max.
Ω min.
100KHz typ.
150mVp-p max.
Notes: All the parameters are measured at 25℃ ambient temperature, humidity < 75%, nominal input voltage,
full load and after warm-up, unless otherwise specified.
MECHANICAL
CONNECTION
PIN #
SINGLE
DUAL
1
+Vin
+Vin
2
GND
GND
8, 17
NC
-Vo
10, 15
0V
0V
12, 13
+Vo
+Vo
9, 11
NC
NC
14, 16
NC
NC
23, 24
NC
NC
Note:
* Unit is mm(inch).
www.pairuigroup.com
Page: 2/4
Date: 07/20/2015
* Subject to change without prior notice
DC-DC Converter
DIP-Package
DAM-2H SERIES, 2WATT, 6KVDC, ISOLATED, UNREGULATED
ELECTRICAL CURVE
NOTE
RECOMMENDED TEST AND APPLICATION CIRCUIT
SINGLE OUTPUT
DUAL OUTPUT
www.pairuigroup.com
Page: 3/4
Date: 07/20/2015
* Subject to change without prior notice
DC-DC Converter
DIP-Package
DAM-2H SERIES, 2WATT, 6KVDC, ISOLATED, UNREGULATED
NOTE
CAPACITOR SELECTION
INPUT VOLTAGE
C1
SINGLE OUTPUT
C2
5VDC
4.7μF
5VDC
4.7μF
12VDC
2.2μF
9VDC
2.2μF
24VDC
1.0μF
12VDC
1.0μF
--
--
15VDC
1.0μF
www.pairuigroup.com
Page: 4/4
DUAL OUTPUT
±5VDC
±9VDC
±12VDC
±15VDC
C2
4.7μF
2.2μF
1.0μF
1.0μF
Date: 07/20/2015
* Subject to change without prior notice