MP49 - Pletronics, Inc.

MP49 Series
HC-49/U Crystal
February 2015
• The Pletronics’ MP49 Series is a thru-hole
crystal
• Bulk packaging
• 1.8 MHz to 210 MHz
• AT Cut Crystal
Pletronics Inc. certifies this device is in accordance with the
RoHS (2011/65/EC) and WEEE (2002/96/EC) directives.
Pletronics Inc. guarantees the device does not contain the following:
Cadmium, Hexavalent Chromium, Lead (<1000 ppm), Mercury, PBB’s, PBDE’s
Weight of the Device: 1.00 grams
Moisture Sensitivity Level: 1 As defined in J-STD-020C
Second Level Interconnect code: e1 or e3
Electrical Specification:
Item
Min
Max
Unit
Condition
1.8432
210
MHz
AT cut
Calibration Frequency Tolerance
-
-
ppm
at +25oC +
_ 3 oC
Frequency Stability over OTR
-
-
ppm
Equivalent Series Resistance
(ESR)
-
700
Ohms
1.8432 MHz to 3 MHz
-
150
Ohms
3 MHz to 4 MHz
-
100
Ohms
4 MHz to 7 MHz
-
50
Ohms
7 MHz to 10 MHz
-
25
Ohms
10 MHz to 37 MHz
-
40
Ohms
21 MHz to90 MHz
3rd Overtone
-
70
Ohms
60 MHz to 150 MHz
5th Overtone
-
100
Ohms
85 MHz to 210 MHz
7th Overtone
-
1
mW
-
7
pF
Aging
-5
+5
ppm /Yr
Specified Temperature Range
-40
+85
o
C
+125
o
C
Frequency Range
Drive Level
Shunt Capacitance
(C0)
Storage Temperature Range
-55
Product information is current as of publication date. The product conforms
to specifications per the terms of the Pletronics limited warranty. Production
processsing does not necessarily include testing of all parameters.
see table on page 3
for available options
Fundamental
use 10 µW for testing
Pad to Pad capacitance
at +25oC +
_ 3 oC
see table on page 3 for available options
Copyright © 2010, Pletronics Inc.
MP49 Series
HC-49/U Crystal
February 2015
AT Cut Crystal Frequency
versus Temperature
Typical Performance:
160
140
120
Deviation (ppm)
100
80
60
40
20
0
-20
-40
-60
-80
-100
-120
-140
-160
-60
-40
-20
0
20
40
60
80
100
120
Temperature (oC)
Part Marking:
PLE
MP49x
FFFFFM
ymdz
or
PLE
SRMP49
FFFFFM
ymdz
Legend:
x
= Capacitance load code from below
FFFFFM
= Frequency in MHz
PLE = Pletronics
ymd = Date of Manufacture (year, month and day)
All other marking is internal factory codes
Specifications such as frequency tolerance and operating temperature range, etc. are not identified
from the marking. External packaging labels and packing list will correctly identify the ordered
Pletronics part number.
Code
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
T
U
V
W
X
Y
pF
10
12
13
8
15
18
20
22
24
26
28
30
32
34
36
27
33
50
19
16
17
14
Codes for Date Code YMD
Code
Year
2
2012
Code
A
JAN
Month
Code
3
2013
1
4
2014
B
FEB
5
2015
C
MAR
2
3
D
APR
4
6
2016
E
MAY
5
F
JUN
6
7
2017
8
2018
G
JUL
H
AUG
J
SEP
7
8
9
K
OCT
L
NOV
M
DEC
A
B
C
Day
1
2
3
4
5
6
7
8
9
10
11
12
Code
D
E
F
G
H
J
K
L
M
N
P
R
20
21
22
23
24
Day
13
14
15
16
17
18
19
Code
T
U
V
W
X
Y
Z
Day
25
26
27
28
29
30
31
www.pletronics.com
425-776-1880
2
MP49 Series
HC-49/U Crystal
February 2015
Part Number:
MP49 -18
-14.31818M
-50
H 1 G G
See chart below for available options
-XX
Internal code or blank
Highest Specified Operating Temperature
A = 40oC
G = 70oC
o
B = 45 C
H = 75oC
o
C = 50 C
J = 80oC
D = 55oC
K = 85oC
o
E = 60 C
F = 65oC
Lowest Specified Operating Temperature
A = +10oC
F = -15oC
L = -40oC
B = +5oC
G = -20oC
C = 0 oC
H = -25oC
o
D = -5 C
J = -30oC
o
E = -10 C
K = -35oC
Mode: 1 = Fundamental
3 =3rd Overtone
See chart below
Frequency Stability
Calibration Frequency Tolerance (Typ. Values shown)
15 = +
_ 15 ppm at 25oC +
_ 3 oC
20 = +
_ 20 ppm at 25oC +
_ 3 oC
o
30 = +
_ 30 ppm at 25 C +
_ 3oC (Standard)
Frequency in MHz
Cload in pF
Load Resonance from 09 to 44 pF --or– blank for SRMP
Series Model
MP = For load resonant version
SRMP = Series Resonance
Available Frequency Stability versus Temperature in ppm
Operating
Temperature Range
D
E
F
G
H
J
CODE
_ 10
+
_ 15
+
+
_ 20
+
_ 30
+
_ 50
+
_ 100
0 to +45oC
CB
!
!
!
!
!
!
0 to +50oC
CC
!
!
!
!
!
!
0 to +60oC
CE
!
!
!
!
!
!
0 to +70oC
CG
!
!
!
!
STD
!
-10 to +50oC
EC
!
!
!
!
!
!
-10 to +60oC
EE
!
!
!
!
!
!
-10 to +75oC
EH
!
!
!
!
!
!
-20 to +70oC
GG
!
!
!
!
!
!
-20 to +75oC
GH
!
!
!
!
!
!
-30 to +75oC
JH
!
!
!
!
!
!
-30 to +80oC
JJ
!
!
!
!
!
!
-30 to +85oC
JK
!
!
!
!
!
!
-35 to +80oC
KJ
!
!
!
!
!
-40 to +85oC
LK
!
!
!
!
!
www.pletronics.com
425-776-1880
3
MP49 Series
HC-49/U Crystal
February 2015
Legacy Part Number (not for new designs):
MP49
B
E
-18
-11.0592M
-XX
Internal code or blank
Frequency in MHz
Cload in pF
Load Resonance in pF –or– blank when SRMP
Operating Temperature Range
Blank = 0 to + 70oC (standard)
E = -40 to +85oC
Calibration Tolerance / Frequency Stability
Blank = 30/50 (STD)
B = 30/30
C = 15/30
D = 10/20 (not all frequencies)
Series Model
MP = for load resonant version
SRMP = for series resonant version
Reliability: Environmental Compliance
Parameter
Condition
Mechanical Shock
MIL-STD-883 Method 2002, Condition B
Vibration
MIL-STD-883 Method 2007, Condition A
Solderability
MIL-STD-883 Method 2003
Thermal Shock
MIL-STD-883 Method 1011, Condition A
Package Labeling
Label is 1" x 2.6" (25.4mm x 66.7mm)
Font is Courier New
Bar code is 39-Full ASCII
www.pletronics.com
425-776-1880
Label is 1" x 2.6" (25.4mm x 66.7mm)
Font is Arial
4
MP49 Series
HC-49/U Crystal
February 2015
Mechanical:
Inches
mm
A
0.425 max
10.80 max
B
0.404
10.26
C
0.192
4.88
D
0.017 dia
0.43 dia
E
0.500 min
12.7 min
F
0.176 max
4.47 max
G
0.145
3.68
H
0.52 max
13.21 max
Contacts (3 types of lead plating used):
Matte Tin (Sn)
Tin over Copper (SnCu)
SAC (SnAgCu)
Not to Scale
1
Typical dimensions
Layout and application information
•
•
•
Trace lengths to the crystal should be kept as short as possible.
The crystal connections are sensitive to noise.
The package should be grounded for optimum performance.
www.pletronics.com
425-776-1880
5
MP49 Series
HC-49/U Crystal
February 2015
IMPORTANT NOTICE
Pletronics Incorporated (PLE) reserves the right to make corrections, improvements, modifications and
other changes to this product at anytime. PLE reserves the right to discontinue any product or service
without notice. Customers are responsible for obtaining the latest relevant information before placing
orders and should verify that such information is current and complete. All products are sold subject to
PLE’s terms and conditions of sale supplied at the time of order acknowledgment.
PLE warrants performance of this product to the specifications applicable at the time of sale in accordance
with PLE’s limited warranty. Testing and other quality control techniques are used to the extent PLE deems
necessary to support this warranty. Except where mandated by specific contractual documents, testing of
all parameters of each product is not necessarily performed.
PLE assumes no liability for application assistance or customer product design. Customers are responsible
for their products and applications using PLE components. To minimize the risks associated with the
customer products and applications, customers should provide adequate design and operating safeguards.
PLE products are not designed, intended, authorized or warranted to be suitable for use in life support
applications, devices or systems or other critical applications that may involve potential risks of death,
personal injury or severe property or environmental damage. Inclusion of PLE products in such applications
is understood to be fully at the risk of the customer. Use of PLE products in such applications requires the
written approval of an appropriate PLE officer. Questions concerning potential risk applications should be
directed to PLE.
PLE does not warrant or represent that any license, either express or implied, is granted under any PLE
patent right, copyright, artwork or other intellectual property right relating to any combination, machine or
process which PLE product or services are used. Information published by PLE regarding third-party
products or services does not constitute a license from PLE to use such products or services or a warranty
or endorsement thereof. Use of such information may require a license from a third party under the patents
or other intellectual property of the third party, or a license from PLE under the patents or other intellectual
property of PLE.
Reproduction of information in PLE data sheets or web site is permissible only if the reproduction is without
alteration and is accompanied by associated warranties, conditions, limitations and notices. Reproduction
of this information with alteration is an unfair and deceptive business practice. PLE is not responsible or
liable for such altered documents.
Resale of PLE products or services with statements different from or beyond the parameters stated by PLE
for that product or service voids all express and implied warranties for the associated PLE product or
service and is an unfair or deceptive business practice. PLE is not responsible for any such statements.
Contacting Pletronics Inc.
Pletronics Inc.
19013 36th Ave. West
Lynnwood, WA 98036-5761 USA
Tel: 425-776-1880
Fax: 425-776-2760
E-mail: [email protected]
URL: www.pletronics.com
Copyright © 2009, 2010 Pletronics Inc.
www.pletronics.com
425-776-1880
6