PB271 Series

PB271 Series
RAILWAY CONVERTERS
1 5 0 W AT T S R A I LW AY D C / D C C O N V E R T E R
FEATURES
•
•
•
•
•
•
•
•
•
Rugged DC/DC converter for railway applications
45-154Vdc input / 12 or 24Vdc output.
High temperature operation, no cooling fan.
Up 60°C ambient with full load, derate up to 90°C.
Shock & vibration protection (potted).
Overvoltage, short circuit, over-temperature,
input transients & reverse polarity protection.
Complies with EN50121-3-2: 2000 and EN50155: 1996
Output terminal, available in screw, cage clamp
or phoenix terminals.
Designed & manufactured in Australia.
SPECIFICATIONS
INPUT
STANDARDS
Voltage
45-154Vdc
Safety
Complies with AS/NZS60950:2000
Current
4.2A
Isolation
In/Cha 2121Vdc, 1 min.
In/Out 4242Vdc, 1 min.
Out/Cha 707Vdc, 1 min.
EMC
Electrical service
conditions
Complies with EN50121-3-2: 2000
Complies with EN50155: 1996
Overvoltage protection
At 160Vdc, auto recovery.
General
Reverse voltage
protection
Indefinite, series blocking diode on input.
MECHANICAL
Chassis mount enclosure
Voltage
See Table
Current
See Table
Input & output connection -S: 4 way screw T/B 20A/300V suitable for up to
4mm² wire
-C: 5 way cage clamp T/B 20A/300V suitable for
up to 4mm² wire
-P: 4 way pluggable T/B 20A /300V suitable for
up to 4mm² wire
Power
150 watts.
Ground Terminal
M4x12 stud (C & S versions only).
Ripple & noise
30mV p-p
Length
Line regulation
Load regulation
Overvoltage protection
0.5% of Vnom
3%of Vnom @ Vout =12V, 1.5% of Vnom @
Vout = 24V
O/P: 130% of Vnom, manual restart required.
Overcurrent protection
110% of Inom, auto recovery.
Short circuit protection
Over temperature
protection
Efficiency
Indefinite, auto recovery.
Auto recovery.
290mm
80mm (without heatsinks) 130mm (with
heatsinks)
-S: 69mm
-C: 73mm
-P: 51mm
1.9kgs (without heatsinks) 2.4kgs (with
heatsinks)
Sylgard 170, V0 rated, MIL grade thermally
conductive silicon elastomer
OUTPUT
Height
(Including terminals)
Weight (unpacked)
Potting
85% at full load.
ENVIRONMENTAL
Operating Temperature
Width
PB271 ORDERING INFORMATION
“H”, with optional heat sink
-20°C – 60°C (Full load).
Derate from 60°C to zero load at 90°C.
Without optional heat sink
-20°C – 40°C (Full load).
Derate from 40°C to zero load at 85°C.
Relative Humidity
5 – 90% (non-condensing)
Cooling
Natural convection
Doc. No. PBC9 Rev.C 28-4-11
PB271
1
_
12
2
S
3
_
H
4
1. Series name
2. Output voltage
-12
-24
3. Output connection
-S (Screw terminal block)
-C (Cage clamp terminal block)
-P (Pluggable terminal block)
4. Optional
- Heatsinks
Powering Progress – www.powerbox.com.au
469
RAILWAY CONVERTERS
PB271 Series
1 5 0 W AT T S D C / D C S I N G L E R A I LW AY
S VARIANT, WITH HEATSINKS
S VARIANT, WITH NO HEATSINKS
470
Doc. No. PBC9 Rev.C 28-4-11