National Instruments TB

INSTALLATION GUIDE
TB-2715 TERMINAL BLOCK
This installation guide describes how to install and connect signals to the
TB-2715 terminal block for use with PXI-653X and PXI-660X modules.
Use the TB-2715 terminal block to connect to the signals of a PXI-653X or
PXI-660X module. Connect your signals to the screw terminals housed in
the terminal block then install the TB-2715 to the PXI front panel.
What You Need to Get Started
To set up and use the TB-2715, you will need the following:
❑ TB-2715 terminal block
❑ Quick-reference labels for PXI-653X and PXI-660X
❑ One of the following:
–
PXI-653X module
–
PXI-660X module
❑ 653X User Manual or 660X User Manual
❑ 0.10 in. slotted screwdriver
❑ Number 1 Phillips screwdriver
❑ Wire cutters
❑ Wire insulation stripper
Connecting Signals to Your Terminal Block
Refer to Figure 1 as you perform the following steps to connect signals
from the peripheral device to the TB-2715. For more information about
connecting signals to your terminal block, see your 653X User Manual or
660X User Manual.
National Instruments™, ni.com™, and PXI™ are trademarks of National Instruments Corporation. Product and company names mentioned herein are
trademarks or trade names of their respective companies.
322984A-01
© Copyright 2000 National Instruments Corp. All rights reserved.
December 2000
1
2
11
7
3
10
9
4
8
5
7
6
1
2
3
Cover
Cover Screws
Strain-Relief Bar
4
5
6
EMI Gasket
7
APD Shield
8
Strain-Relief Screws 9
Terminal Block Mounting Screws
PXI Module Connector
Chassis Ground Tab
10 Ground Solder Lug
11 Ground Lug Screw
Figure 1. TB-2715 Parts Locator Diagram
1.
Remove the terminal block cover by unscrewing the two cover screws
using the 0.10 in. slotted screwdriver.
2.
Apply the appropriate quick reference label to the inside of the top
cover as shown in Figure 2. This label provides the corresponding
signal names on the PXI module for each pin number.
TB-2715 Terminal Block Installation Guide
2
ni.com
PIN
#
30
SI
DA GNA
C L
AO 6 OU
AO GN T
DA GN D
C D
AO 4OU
PIN
19
AO GND T
#
52
28
AO GND
17
G
61
SI
DI ND
53
59
O
DA GNA
DI 4
9
PIN
C L
62
O
AO 5OU
DI 0
#
51
25
68
DG O1
AO GN T
49
58
ND
34
GN D
D
SIG
47
GN
27
29
DA NC D
NA
DI D
45
C3
21
O5
L
33
AO OU
DI
10
AO NC
20
O
66
AO GND T
EX DIO 2
14
AO GN
5
G
5
2
D
T
4
G D
AC ND
ST 3
40
16
65
N ND
EX 1OU
PF ROB
38
AO C
4
T
T
E
I
8
3
1
AO RE
GP +5 1
AO GN
3
35
G F
56
CT V
DA GN D
36
DI ND
R1
11
D
C
57
O
PF _O
AO 7OU
DI 6
4
U
23
PF I7 T 4 3
DG O7
AO GN T
1
22
N
DG I9
DA GN D
PF D
6
ND
C D
54
AO 2O
PF I0
4
8
DA GN UT
PF I2
C D
46
AO 0OU
PF I4
50
G T
DG I5
+5 ND
42
ND
V
18
N
DG C
5
ND
37
DG
2
N
PF D
1
I6
GP
C
FR TR0
EQ _O
_O UT
UT
67
63
PFI3
32
64
26
60
PFI8
Figure 2. Inserting the Quick-Reference Label
3.
Loosen or remove the strain-relief bar by loosening the two
strain-relief screws with a Number 1 Phillips screwdriver.
4.
Use wire cutters and wire insulation strippers to strip no more than
7 mm of insulation from the wire ends.
5.
Use Figures 3 and 4 to find the 653X and 660X signals that correspond
to the screw terminals on the TB-2715. Please note that lines 19, 35,
43, and 56 are not connected.
© National Instruments Corporation
3
TB-2715 Terminal Block Installation Guide
PIN# SIGNAL
57
C1
24
GND
58
C2
25
C3
59
GND
26
C4
60
C5
27
GND
61
C6
28
C7
62
GND
29
D0
63
D1
30
GND
64
D2
31
D3
65
GND
32
D4
66
D5
33
GND
67
D6
34
D7
PIN#
2
36
3
37
4
38
5
39
6
40
7
41
8
42
9
10
44
11
45
12
46
13
PIN# SIGNAL
47
A5
14
GND
48
A6
15
A7
49
GND
16
B0
50
GND
17
B1
51
B2
18
GND
52
B3
53
B4
20
GND
54
B5
21
B6
55
GND
22
B7
23
C0
SIGNAL
REQ1
GND
ACK1
GND
STOP1
DPULL
PCLK1
GND
PCLK2
CPULL
STOP2
GND
ACK2
GND
REQ2
A0
A1
GND
A2
A3
GND
A4
PIN# SIGNAL
1
+5V
68 GND
Figure 3. Pinout Diagram for PXI-653X Modules
PIN# SIGNAL
PIN# SIGNAL
57 PFI_17(UP_DOWN_5)
24
GND
58
PFI_18(GATE_5)
25 PFI_19(SOURCE_5)
59
GND
26
PFI_20(OUT_4)
60 PFI_21(UP_DOWN_4)
27
GND
61
PFI_22(GATE_4)
28 PFI_23(SOURCE_4)
62
GND
29
PFI_24(OUT_3)
63 PFI_25(UP_DOWN_3)
30
GND
64
PFI_26(GATE_3)
31 PFI_27(SOURCE_3)
65
GND
32
PFI_28(OUT_2)
66 PFI_29(UP_DOWN_2)
33
GND
67
PFI_30(GATE_2)
34 PFI_31(SOURCE_2)
PIN# SIGNAL
47
PFI_5(DIO_5)
14
GND
48
PFI_6(DIO_6)
15
PFI_7(DIO_7)
49
GND
16
PFI_8(OUT_7)
50
GND
17 PFI_9(UP_DOWN_7)
51
PFI_10(GATE_7)
18
GND
52 PFI_11(SOURCE_7)
53
PFI_12(OUT_6)
20
GND
54 PFI_13(UP_DOWN_6)
21
PFI_14(GATE_6)
55
GND
22 PFI_15(SOURCE_6)
23
PFI_16(OUT_5)
2 PFI_39(SOURCE_0)
36
GND
3
PFI_36(GATE_0)
37
RESERVED
4
RESERVED
38
RESERVED
5
PFI_38(OUT_0)
39
GND
PIN# SIGNAL
1
+5V
68
GND
6 PFI_33(UP_DOWN_1)
40 PFI_37(UP_DOWN_0)
7 PFI_35(SOURCE_1)
41
GND
8
PFI_34(GATE_1)
42
GND
9
PFI_32(OUT_1)
10
PFI_0(DIO_0)
44
PFI_1(DIO_1)
11
GND
45
PFI_2(DIO_2)
12
PFI_3(DIO_3)
46
GND
13
PFI_4(DIO_4)
Figure 4. Pinout Diagram for PXI-660X Modules
6.
Loosen the screws in the screw terminals with the 0.10 in. slotted
screwdriver.
TB-2715 Terminal Block Installation Guide
4
ni.com
7.
Insert the stripped wires into the screw terminals. If you are using a
shielded cable, expose the shield and allow it to make contact with the
EMI gasket.
8.
Tighten the screws with the 0.10 in. slotted screwdriver.
9.
Connect safety ground or shield wires to the chassis ground connection
tab using the provided solder lug and ground lug screw.
10. Tighten or replace the strain-relief screws.
11. Replace the terminal block cover and tighten the cover screws.
Connecting the TB-2715 to Your PXI Module
Refer to Figure 5 as you perform the following steps to connect the
terminal block to your PXI module.
2
3
1
2
3
4
5
6
7
8
1
1
2
Terminal Block Mounting Screws
PXI Chassis
3
PXI Module Connector
Figure 5. Connecting the TB-2715 to Your PXI Module
1.
Install your PXI module into the chassis and tighten the two module
screws. You must install the PXI module in the PXI chassis before the
TB-2715 is connected to the PXI module.
2.
Guide the terminal block onto the module connector.
3.
Tighten the two terminal block mounting screws.
Insert the terminal block as shown in Figure 5. The TB-2715 can be attached to a
PXI module only one way. Do not force the terminal block when attaching or removing it
to avoid damaging the TB-2715 or PXI module.
Caution
© National Instruments Corporation
5
TB-2715 Terminal Block Installation Guide