Two-Terminal vs. Four-Terminal Resistors

RESISTORS • CAPACITORS • COILS • DELAY LINES
2-TERMINAL VS. 4-TERMINAL RESISTORS
RCD APPLICATION NOTE R-31
a
b
I2
I1
E1
"Kelvin" (four-terminal) connections are often required
in current shunts and current sensors to achieve optimum
performance and accuracy. The four-terminal method of
measurement eliminates inaccuracy attributable to lead
resistance, which can be quite significant in low-value
resistors. Furthermore, the use of four-terminal
connections avoids the TCR (temperature coefficient of
resistance) contribution of the lead wires, thereby
resulting in tighter thermal stability compared to
conventional two-terminal shunts.
The above figure illustrates the four-terminal connection
(developed by Lord Kelvin) that enables the voltage drop
to be measured across the resistance element itself
instead of the element and lead wires. One pair of leads
is used for voltage measurement and the other for current
sensing. The voltage between E1 and E2 is proportional
to the current flow between I1 and I2 and the resistance
between junctions "a" and "b". The voltage circuit has a
high impedance so it draws no significant current. With
no current through the sense leads, there can be no lead
voltage drop, and therefore the lead resistance is
eliminated. Furthermore, the TCR of the current leads is
eliminated since the voltage connections are generally
affixed directly (or very close) to the resistance element.
Errors/inaccuracies attributable to lead resistance,
contact resistance, and temperature coefficient are
therefore greatly minimized via use of "kelvin" circuits.
An alternative to 4-terminal resistors for less demading
applications is to utilize 2-terminal resistors by running a
pair of circuit traces to each terminal, one for current and
one for voltage sense.
R-31 Rev. A Page 1 of 2
E2
EXAMPLE OF 2-TERMINAL VS. 4-TERMINAL
PERFORMANCE
&RQVLGHUWKHUHTXLUHPHQWIRUDP“
watt axial lead resistor. Low-ohm resistors are generally
measured at a distance of 3/8" from the body, which
HTXDWHVWRDOHDGUHVLVWDQFHRIQHDUO\PSHUOHDG
(based on .032 copper leads). The total resistance of
PLVFRPSULVHGRIDSSUR[LPDWHO\PIURPWKH
OHDGZLUHVDQGPIURPWKHLQWHUQDOUHVLVWDQFHHOHPHnt.
Consideration #1: Inaccuracy Attributable To Mounting
Variation
Since 20% of the total resistance is attributable to the
lead wires, it would be essential for the user to assemble
the parts into the circuit at essentially the same spot on
the leads that the manufacturer used to measure the
resistance value,
in order maintain the 1% in-circuit tolerance.
Considering the wide variety of mounting spans
(distance between leads), mounting profiles (height off
board), and
mounting configurations (horizontal vs. vertical), it is
often a difficult objective to match lead lengths.
Manufacturers will often customize parts to match the
customers' lead spacing requirements, however variation
can still result in unacceptable in-circuit resistance due to
inconsistent lead formation, inconsistent positioning, etc.
A variation of only 1/8" from the recommended
measurement spacing of 3/8" (combined variation of
ZRXOGHTXDWHWRPRU“LQWKLVH[DPSOH
7KHUHIRUHDUHVLVWRUWKDWPHDVXUHGH[DFWO\PDWWKH
manufacturer's spacing, would be approximately 6%
higher with an extra 1/4" of lead wire in the circuit,
thereby falling well outside the 1% in-circuit tolerance.
In order to maintain a 1% in-circuit tolerance utilizing a
two-terminal axial lead resistor, the customer would have
to specify a tighter tolerance (such as ±0.5% or 0.1%).
With a 0.5% tolerance resistor, the user would still need
to match the manufacturer's test spacing within .020" to
amaintain a 1% in-circuit tolerance (since .020" would
account for the remaining 0.5% allowable inaccuracy).
The recommended alternative is to utilize a 10mterminal device (such as RCD LVF-3). This way, the
lead spacing and inconsistencies associated with
assembly, could be disregarded. In addition, there would
be a cost savings involved in buying a ±1% 4-terminal
resistor vs. a ±0.5% or 0.1% 2-terminal resistor.
Consideration #2: Resistance Shift Due To Self-Heating
,QWKHH[DPSOHDERYHRIWKHPUHVLVWDQFHLV
contributed by the leadwires. Copper has a TCR of
approximately +3800ppm/ºC (+.38%/ºC), and therefore
WKHOHDGZLUHRIDPD[LDOOHDGUHsistor would
contribute approximately +760ppm to the TCR of the
internal resistance element. Depending on the power
applied, resistors often heat up 100ºC to 200ºC (or
higher) above ambient. So even if the internal resistance
element had a TCR of "zero", a 10m-terminal resistor
would shift roughly +5% to +10% due to TCR
contribution of the leadwires alone (the amount of shift
depends on the power level and how hot the leads
themselves become). By utilizing a 4-terminal device,
the thermal instability due to leadwire TCR is greatly
minimized.
RCD manufactures the industry's widest range of 2terminal and 4-terminal current sensors/current shunts...
[Resistance values as low as 0.00001Ÿ
[Wattage ratings 1/2W to 10,000W
[Current ratings 1/4A to 5000A
[TCR's as tight as 5ppm/ºC
[Leaded and Surface Mount designs in 2- and 4terminal designs
[High-volume offshore production enables significant
cost savings over comparable models
[Delivery from stock on many standard values
Contact RCD Engineering for application assistance.
RCD Components Inc. 520 East Industrial Park Dr., Manchester, NH, USA 03109
TEL: (603)669-0054 FAX: (603)669-5455 www.rcdcomponents.com
R-31 Rev. A Page 2 of 2