Pulse Capability Derating Factors

RESISTORS • CAPACITORS • COILS • DELAY LINES
APPLICATION GUIDE R-42
Pulse Capability Derating Factors
Unless indicated otherwise on RCD’s data sheet, the resistor peak pulse voltage, wattage, and/or energy ratings are based
on single capacitive discharge pulse with RC time constant of 1uS at 25ºC and RH <65% at altitude <10,000 ft. Derate for
multiple pulses, longer pulse durations, and environmental conditions as detailed below. The pulse rating shall be the lower
of the peak power, voltage, or energy rating after applying the derating factors.
Peak Pulse Voltage Rating
Peak pulse ratings are in accordance with RCD data sheets when tested per the pulse test circuit is in accordance with
DSCC (Defense Supply Center) Drawing 03007 par. 4.11 “Resistance to Pulse Test Circuit” with capacitance value selected
to limit the RC time constant to 1uS. Circuit for 1KΩ resistor is illustrated below. For longer pulses, derate in
accordance with “Peak Pulse Rating as a Function of Pulse Width” chart below.
Resistance Value
1KΩ
10KΩ
100KΩ
100MΩ
Capacitance
1000pF
100pF
10pF
1pF
Table 1. Capacitance Value to be Utilized in Pulse Test Circuit
Peak Pulse Voltage Rating as a Function of Pulse Width:
Percentage of Peak Pulse Voltage Rating
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
≤1uS
10uS
100uS
Pulse Width
R-42 Rev.A P.1 of 3
1mS
10mS
Pulse Energy Rating As A Function of Pulse Width, Series PR & PRM
Derating the Single-Pulse Surge Rating for Multiple or Repetitive Pulse Streams:
a) Firstly, the pulse must not exceed the single peak power pulse rating given in the applicable Surge Capability chart for
given time duration, and also must not exceed the rated peak pulse voltage levels. The peak pulse voltage capability is
generally well above the Max. Continuous Voltage Rating and if not listed on data sheet is often available on the Surge
Application Guide for the product in question (if not, consult RCD’s engineering department). Note: elevated ambient
temperatures can impact surge capability and should be derated accordingly (refer to data sheet).
b) Resistors subjected to multiple pulses or repetitive pulse streams must meet the criteria for a single pulse, and the
average power must not exceed the published wattage rating.
T
Average Power = Pt/T
P= Peak Power (Watts)
t= Pulse duration (Seconds)
T= Cycle Time
P
t
Example: Peak Power (P)= 1000W, pulse duration (t) = 10uS, cycle time =
60Hz (.01667S)... 1000W x .00001S / .01667S = .6 Watts average power.
c) The single pulse rating is based on Cycle time/Pulse duration (T/t) ratio of 10,000 or greater. For smaller T/t ratios, derate
pulse capability according to following chart. Complete RCD's "Surge Questionnaire Form" if standard or Opt.P (Pulse
Tolerant) construction won't suffice so that we can recommend the optimum resistor for your application. Always verify
selection by evaluating prototypes under worst-case conditions.
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
10,000
1,000
100
Cycle time/Pulse duration (T/t) ratio
R-42 Rev. A Page 2 of 3
10
1
Derating Pulse Capability for Elevated Temperatures:
Elevated ambient temperatures impact pulse as well as continuous performance capability and therefore require derating of
peak and continuous power, voltage, and energy ratings. Continuous power and voltage ratings are to be derated according
to “derating” section on data sheet. Peak pulse voltage, power and energy are to be derated according to chart below.
Percentage of Energy, Peak Pulse Voltage, or
Peak Pulse Power Rating
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
25
50
75
100
125
150
175
200
225
240
Ambient Temperature (ºC)
Derating Pulse Capability for High Altitudes and Humidity:
Power capability is affected by altitude. Operation at high altitudes can also result in corona and arcing, especially in high
humidity environments. Peak pulse voltage, power and energy ratings are to be derated 10% per 10,000 feet. RCD has not
established a derating factor for high humidity, however offers hermetically sealed designs for products utilized in harsh
environments such as tropical or naval.