VDS1140 TR Limiter/ Attenuator

Receiver Protectors
VDS1140 TR Limiter/ Attenuator
Features:
Description:
Passive, high power S-Band Pre-TR, TR Limiter
with integral variable attenuator
· Frequency: 2.7 - 3.0 GHz
· Peak Power:
- Normal Operating: 2 kW
- Overload: 20 kW
· Duty Cycle: 0.11
· Pulsewidth: 100 uSec
· Insertion Loss: 0.7 dB max
· VSWR: 1.4:1 max
· Flat Leakage: 40 mW max
· Spike Leakage: 100 mW max
· Recovery Time: 3 mSec max
· 0 - 30 dB attenuator; analog
control at 3 dB/V
· Waveguide input; SMA output
Phone: 978-922-6000 Fax: 978-922-2736
E-Mail: [email protected]
Internet: www.cpii.com/bmd
150 Sohier Road
Beverly, Massachusetts 01915
Beverly Microwave Division