T04XO - Communications & Power Industries

400W Outdoor TWT Amplifier
for Satellite Communications
X- Band
The T04XO Series
X- Band
400 Watt TWT
Amplifier — high
efficiency in an
environmentally sealed
compact package
designed for outdoor
operation
Easy to Maintain
Provides 400 watts of power in a rugged and
compact weatherproof package, digital ready,
for wideband, single- and multi-carrier satellite
service in the 7.9 - 8.4 GHz frequency band.
Ideal for transportable and fixed earth station
applications.
Modular design and built-in fault diagnostic
capability via remote monitor and control.
Cost Effective and Efficient
Mounting at the antenna improves performance
through minimized cable losses and saves cost in
system design. Employs a high efficiency, dualdepressed collector helix traveling wave tube
reducing operating costs.
Global Applications
Meets International Safety Standard EN-60215,
Electromagnetic Compatibility 2004/108/EC
and Harmonic Standard EN-61000-3-2 to satisfy
worldwide requirements.
Worldwide Support
Backed by over three decades of satellite
communications experience, and CPI’s worldwide
24-hour customer support network that includes
sixteen regional factory service centers.
Reliable
Designed and built to survive in extremely
adverse environmental conditions and features
increased cooling margin for longer life.
Simple to Operate
User-friendly microprocessor-controlled logic
with integrated RS422/485 computer interface.
Digital metering, pin diode attenuation and
optional integrated linearizer for improved
intermodulation performance.
811 Hansen Way
P.O. Box 51625, Palo Alto, CA 94303
tel: +1 (650) 846-3803
fax: +1 (650) 424-1744
e-mail: [email protected]
www.cpii.com/satcom
400W Outdoor TWT Amplif ier
Plays in the Rain
X -B a n d
SPECIFICATIONS, T04XO Series
Electrical
OPTIONS:
Frequency
7.9 - 8.4 GHz
Output Power
TWT
Flange
400 W min. (56.02 dBm)
350 W min. (55.44 dBm)
Bandwidth
500 MHz
Gain
46 dB min. at rated power output
(70 dB with SSIPA)
52 dB min. at small signal
(75 dB with SSIPA)
• Remote Control Panel
• Integrated 1:1 Switch
Control and Drive
Electrical (continued)
• SSIPA with Variable
Attenuator (provides
typical RF Level Adjust
Range of 0 to 30 dB)
Small Signal Gain Slope
±0.02 dB/MHz max.
Small Signal Gain Variation
1.0 dB pk-pk across any 40 MHz band;
2.5 dB pk-pk across the 500 MHz band
4.0 dB pk-pk across 500 MHz with linearizer
• Integral Linearizer
(Requires SSIPA option)
RF Level Adjust Range
0 to 30 dB typ. (SSIPA option required)
Attenuator Step-Size
0.1 dB (SSIPA option required)
Input VSWR
1.3:1 max.
Output VSWR
1.3:1 max.
Load VSWR
2.0:1 max. continuous operation;
any value for operation without damage
Residual AM
-50 dBc below 10 kHz
-20[1.5 +log F (kHz)] dBc,
10 kHz to 500 kHz
-85 dBc above 500 kHz
• L-Band Block
Upconverter (BUC --requires SSIPA --- SEE
NOTE below)
• Forward Power
Detection Over CIF
• Ethernet Interface
Phase Noise
IESS-308/309
10 dB below mask
phase noise continuous
AC fundamentals related
-42 dBc
Sum of spurs (370 Hz to 1 MHz) -47 dBc
Note: This data sheet does
not provide specifications
for when the BUC option
is included. Please refer
to TD-137 or contact CPI
for details.
AM/PM Conversion
2.5°/dB max. for a single carrier at
7 dB below rated power (2.5°/dB max. at
3 dB below rated with linearizer)
Harmonic Output
-60 dBc at rated power
Noise and Spurious
(at rated gain)
-60 dBc per MIL-STD-188-164A, transmit
and receive band
Intermodulation
-24 dBc max. at 7.5 dB OBO per
MIL-STD-188-164A
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
05/10
0.01 ns/MHz linear max.
0.002 ns/MHz 2 parabolic max.
0.5 ns pk-pk ripple max.
Primary Power
90-264 volts AC,
single phase 47-63 Hz
Power Consumption
1350 W typ.
1500 W max.
Power Factor
0.95 min.
Environmental (Operating)
Gain Stability
Ambient Temperature
At constant drive and temp. ±0.25 dB/24hr max. (after 30 min. warmup)
Over temp. constant drive
±1.0 dB over operating temp. range (any freq.);
±0.75 dB over ±10°C
• Redundant and Power
Combined Subsystems
MKT 129, ISSUE 9
Group Delay
(in any 40 MHz band)
PDF
-40°C to +50°C, operating in
direct sunlight;
-40°C to +55°C, operating out
of direct sunlight;
-40°C to +75°C non-operating
Relative Humidity
100% condensing
Altitude
10,000 ft. with standard adiabatic
derating of 2°C/1000 ft., operating;
50,000 ft., non-operating
Shock and Vibration
Designed for normal transportation
environment per Section 514.4
MIL-STD-810E. Designed to
withstand 20G at 11 ms (1/2
sine pulse) in non-operating
configuration.
Acoustic Noise
65 dBA @ 3 ft. from amplifier
Heat Dissipation
1100 W max.
Mechanical
Cooling (TWT)
Forced air with integral blower
RF Input Connection
Type N female
RF Output Connection
CPR-112 G waveguide flange,
grooved with UNC 2B 10-32
threaded holes
RF Output Monitor
Type N female
Dimensions (W x H x D)
10.25 x 10.5 x 20.5 in.
(260 x 267 x 521 mm)
Weight
55 lbs (25.0 kg) with
no options, max.