POL-05006 - Premier Magnetics

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25 OC
FIGURE 1: SCHEMATIC DIAGRAM
SWITCHING TRANSFORMER DESIGNED FOR USE WITH POWER INTEGRATIONS
PWR-TOP210PFI REFER TO APPLICATION CIRCUIT OF FIGURE 3.
(IMPROVED INSULATION VERSION OF TRD1 ON POWER INTEGRATIONS
RD1 REFERENCE DESIGN BOARD)
PARAMETER
MIN.
PRIMARY INDUCTANCE (2-1)
FREQ. = 100 KHZ @ 0.250Vrms
7.10
TURN RATIO'S:
SECONDARY (8-5) : PRIMARY (2-1)
BIAS (4-3) : PRIMARY (2-1)
PRI LEAKAGE IND. (8-5 SHORTED)
FREQ. = 100 KHZ @ 0.250Vrms
HIPOT:
PRIMARY TO SECONDARY
BIAS TO SECONDARY
APP CIRCUIT PARAMETERS: (1)
AC LINE VOLTAGE 47/400 Hz
OUTPUT VOLATGE
OUTPUT CURRENT CONTINUOUS
OUTPUT CURRENT PEAK
LINE REGULATION (85 TO 265Vac)
LOAD REGULATION 10-100%
RIPPLE
SPEC LIMITS
TYP.
MAX.
8.10
DOT ON BOBBIN
DENOTES PIN #1
1
UNITS
9.10
PRIMARY
mHY
2
---------------
1:17.00
1:14.17
---------------
+ 3%
+ 3%
--------
85.0
150.0
µHY
3
8
SECONDARY
5
BIAS
4
3000
3000
---------------
---------------
Vrms
Vrms
85
-------5.0
--------------1.50
5.00
25.0
265
Vac
Vdc
mA
mA
+%
+%
+mV
0.0
-----------------------------
600
800
----------------------
NOTE1:
REINFORCED INSULATION SYSTEM, UL1950, IEC950, CSA-950:
A) ALL MATERIALS MEET "UL", "CSA" & "IEC" REQUIREMENTS
B) TRIPLE BASIC INSULATED SECONDARY.
C) VARNISH FINISHED ASSEMBLY.
D) UL1950 & CSA-950 CERTIFIED: FILE #E162344.
E) UL CLASS (B) 130 INSULATION SYSTEM PM130-R1,
PM130-H1, PM130-H1A (UL FILE #E177139) OR ANY UL
AUTHORIZED CLASS (B) INSULATION SYSTEM.
(1) REFER TO APPLICATION CIRCUIT OF FIGURE 3.
FIGURE 2: PHYSICAL DIMENSIONS mm (INCHES)
WHITE DOT
DENOES PIN#1
8
7
6
5
1
2
3
4
16.8
(.661)
MAX
CORE
TAPED
3.5
(.137)
MIN
15.5
(.610)
MAX
P POL-05006
M YYWW
14.5
(.571)
MAX
1.3
(.051)
1
3.0
(.118)
3
2
3.8
(.150)
P Premier
M Magnetics Inc.
"INNOVATORS IN MAGNETICS TECHNOLOGY"
8
7
6
∅ 0.6
(.024)
4
11.0
(.433)
EE16/EI16, 8-PIN HORIZONTAL
UL INSULATION
SYMBOL AND
MANUFACTURER
IDENTIFICATION
HERE
REV.
08/10/95
12/22/96
07/29/98
05/03/99
DESCRIPTION OF CHANGES
ORIGINAL RELEASE
REVISED INSULSYSTEM TO MEET >3mm CREEPAGE BIAS TO SEC
UPDATED MARKING TO UL - NO OTHER CHANGES
UPDATE TO UL CLASS (B) INSULATION SYSTEM
BY
TO
TO
AS
MD
5
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN MM
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ .25
+0 O 30'
.XX + .15
DO NOT SCALE DRAWING
TRANSFORMER CONTROL DRAWING
PREMIER P/N: POL-05006
REVISION: 05/03/99
DRAWN BY: TOM O'NEIL
REF: PWR-TOP210PFI
SCALE: NONE
SHEET: 1 OF 6
APPLICATION NOTES
Premier Magnetics' POL-05006 Switch Mode Transformer was designed for use with Power Integrations, Inc.
PWR-TOP210PFI three terminal off-line PWM switching regulator in the Flyback Buck-Boost circuit configuration.
This conversion topology can provide isolated multiple outputs with efficiencies up to 90%. Premiers' POL-05006
transformer has been optimized to provide maximum power throughput.
The PWR-TOPXXX series from Power Integrations, Inc. are self contained 100KHz three terminal voltage
controlled PWM switching regulators. This series contains all necessary functions for an off-line switched mode
control DC power source. These switching regulators provide a very simple solution to off-line designs. The
inductors and transformer used with the PWR-TOPXXX are critical to the performance of the circuit. They define
the overall efficiency, output power and overall physical size.
Below is a universal input, 3 watt application circuit utilizing Power Integrations PWR-TOP210 switching regulator
in the flyback buck-boost configuration. This circuit provides +5Vdc at 600mA continuous and is capable of
800mA peak for short periods of time. This circuit represents the lowest cost implementation and utilizes the bias
winding for feedback control. As such the line & load regulation are worse than that which could be achieved
by utilizing an opto-coupler to sense the actual outputs. If tighter line/load regulation is required please refer to
Premier Magnetics TSD-816 data sheet. The component values listed are intended for reference purposes only.
Resistor R1 may be adjusted up to 50 Ohms MAX. and down to 10 Ohms MIN. As R1 increases in value the
output voltages will increase, and vice-versa, thus allowing some fine adjustment on the initial output voltage.
The EMI/RFI capacitors C7 & C8 are shown for reference but may not be needed to meet EMI/RFI emmision
specifications.
FIGURE 3: TYPICAL APPLICATION CIRCUIT
F1
1.5A
250v
BR1
DF06S
600V, 1.0A
EMI FILTER
LINE
1
L1
PMCU-0220
22mHY
~
2
+
HOT RAIL
+110 to 375Vdc
C1, 22.0 uF, 400V
Low Profile Type:
Nichicon # UVS2G220MRA, 85C
Nichicon # URT2G220MRA, 105C
Diameter=18mm (.708)
Length=20mm (.787)
C1
22 uF
400V
+
85-265Vac
50/60Hz
C6
0.1uF
4
NEUT
3
~
-
PREMIER MAGNETICS PART NUMBERS:
(REQUEST DATA SHEETS BY PART#)
L1 = PMCU-0220 22mHy EMI/RFI CMC
T1 = POL-05006 MAIN SWITCHING TRANSFORMER
L2 = VTP-01001 10uHy, 1.0Amp INDUCTOR
C6 = 0.1uF 250Vac
X2-Saftey Cap
CLAMP
NETWORK
1
VR1
P6KE120A
PRI
D1
MUR160
8
2
R1
15
C2
330uF
10V
D2
1N4148
SEC
4
L2
VTP-01001
10uH @ 1.0A
D3
1N5822
5
+
+5Vdc
@ 600mA
C3
+
100uF
10V
RTN
BIAS
DRAIN
U1
POWER INT.
PWR-TOP210PFI
D
C
N/C
N/C
N/C
N/C
S
3
T1
POL-05006
CONTROL
S
SOURCE
+
C5
47uF
10V
C7 & C8 = 250Vac
Y-SAFTEY CAPACITORS
EMI FILTER
C7
2.2nF
C8
2.2nF
HIGH VOLTAGE RETURN
P Premier
M Magnetics Inc.
"INNOVATORS IN MAGNETICS TECHNOLOGY"
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN MM
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ .25
+0 O 30'
.XX + .15
DO NOT SCALE DRAWING
TRANSFORMER CONTROL DRAWING
PREMIER P/N: POL-05006
REVISION: 05/03/99
DRAWN BY: TOM O'NEIL
REF: PWR-TOP210PFI
SCALE: NONE
SHEET: 2 OF 6