TABLE 1: ELECTRICAL SPECIFICATIONS AT 25 OC FIGURE 1: SCHEMATIC DIAGRAM SWITCHING TRANSFORMER DESIGNED FOR USE WITH POWER INTEGRATIONS PWR-TOP224. REFER TO APPLICATION CIRCUIT OF FIGURE 3. PARAMETER MIN. SPEC LIMITS TYP. PRIMARY INDUCTANCE (3-1) VOLTAGE = 0.250Vrms FREQUENCY = 100 KHZ 720 800 MAX. UNITS 880 µHY WHITE DOT ON BOBBIN DENOTES PIN #1 10 1 9 PRI #1A & #1B TURN RATIO'S: SEC #1 (10-8) : PRIMARY (2-1) SEC #2 (7-6) : PRIMARY (2-1) BIAS (4-5) : PRIMARY (2-1) PRI LEAKAGE IND. (SEC SHORTED) VOLTAGE = 0.250Vrms FREQUENCY = 100 KHZ ---------------------- 1: 2.40 1: 9.60 1: 6.00 ---------------------- + 4% + 4% + 4% -------- -------- 8.0 µHY 2 8 4 7 BIAS 5 HIPOT: PRIMARY TO SECONDARY BIAS TO SECONDARY 3000 3000 --------------- --------------- Vrms Vrms APP CIRCUIT PARAMETERS: (1) AC LINE VOLTAGE 47/400 Hz SEC #1 OUTPUT VOLTAGE SEC #1OUTPUT CURRENT SEC #2 REGULATED OUTPUT SEC #2 OUTPUT CURRENT 85 -------25.0 -------0.0 -------15.0 -------6.9 -------- 265 -------800 -------350 Vac +Vdc +mA Vdc mA SEC #1 + 15Vdc SEC #2 +6.9Vdc 6 NOTE1: REINFORCED INSULATION SYSTEM, UL1950, IEC950, CSA-950: A) ALL MATERIALS MEET "UL", "CSA" & "IEC" REQUIREMENTS B) TRIPLE BASIC INSULATED SECONDARY. C) DESIGNED TO MEET >6.2mm CREEPAGE REQUIREMENTS. D) VARNISH FINISHED ASSEMBLY. E) UL1950 & CSA-950 CERTIFIED: FILE #E162344. F) UL CLASS (B) 130 INSULATION SYSTEM PM130-R1, PM130-H1, PM130-H1A (UL FILE #E177139) OR ANY UL AUTHORIZED CLASS (B) INSULATION SYSTEM. (1) REFER TO APPLICATION CIRCUIT OF FIGURE 3. FIGURE 2: PHYSICAL DIMENSIONS mm (INCHES) 10 9 8 7 6 P TSD-1432 M YYWW PIN #1 I.D. 1 2 3 4 5 29.3 (1.154) MAX 23.5 (.925) MAX CORE TAPED UL INSULATION SYMBOL AND MANUFACTURER IDENTIFICATION HERE 34.5 (1.358) MAX 1 PIN #1 I.D. 5 4.5 (.177) 5.0 (.197) 1 2 3 4 3.0 (.118) 0.8 DIA (.032) 5 17.5 (.689) 10 EER28L, 10-PIN VERTICAL BOBBIN 9 8 7 6 25.5 (1.004) P Premier M Magnetics Inc. "INNOVATORS IN MAGNETICS TECHNOLOGY" UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MM DIMENSIONAL TOLERANCES ARE: DECIMALS ANGLES .X + .25 +0 O 30' .XX + .15 DO NOT SCALE DRAWING REV. DESCRIPTION OF CHANGES BY 06/15/99 07/06/99 ORIGINAL RELEASE, TSD-860 MODIFIED FOR LOWEST TEMP. RISE REDUCED LEAKAGE INDUCTANCE BASED ON ACTUAL PARTS TO TO 10/01/99 01/13/00 UPDATE TO UL CLASS (B) 130 INSULATION SYSTEM UPDATE TO UL RECOGNIZED FILE #E162344 MD MD FLYBACK TRANSFORMER CONTROL DRAWING PREMIER P/N: TSD-1432 REVISION: 01/13/00 DRAWN BY: TOM O'NEIL REF: PWR-TOP224 SCALE: NONE SHEET: 1 OF 6 APPLICATION NOTES Premier Magnetic's TSD-1432 Switch Mode Transformer was designed for use with Power Integrations, Inc. PWRTOP224Y three terminal off-line PWM switching regulator in the Flyback Buck-Boost circuit configuration. This conversion topology can provide isolated multiple outputs with efficiencies up to 90%. Premier's TSD-1432 transformer has been optimized to provide the specified power throughput while also providing for a low transformer temperature rise. The PWR-TOPXXX series from Power Integrations, Inc. are self contained 100KHz three terminal voltage controlled PWM switching regulators. This series contains all necessary functions for an off-line switched mode control DC power source. These switching regulators provide a very simple solution to off-line designs. The inductors and transformer used with the PWR-TOPXXX are critical to the performance of the circuit. They define the overall efficiency, output power and overall physical size. Below is a universal input high precision 26 watt application circuit utilizing Power Integrations PWR-TOP224 switching regulator in the flyback buck-boost configuration. The component values listed are intended for reference purposes only. A properly sized heat sink for the PWR-TOP224+ is required for efficient and reliable operation. Soft start capacitor Css is optional and application dependent. FIGURE 3: TYPICAL APPLICATION CIRCUIT PREMIER MAGNETICS PART NUMBERS: (REQUEST DATA SHEETS BY PART#) L1 = PMCU-0330 33mHy EMI/RFI CMC T1 = TSD-1432 MAIN SWITCHING TRANSFORMER L2 = VTP-01001 10uHy, 1.0Amp INDUCTOR BR1 DF04M 400V, 1.0A EMI FILTER F1 3.1A 250v LINE 1 ~ 2 + C1 47 u F 400V C6 0.1uF 4 NEUT HOT RAIL +84 to 375Vdc 3 ~ D5 MUR120 (UF4002) + 85-265Vac 50/60Hz L1 PMCU-0330 33mHY ALUMINUM ELECTROLYTIC FILTER CAPACITOR RATINGS: +15V OUTPUT: C10 & C12 >25V, Ripple Rated > 400mA @ 100KHz @ Max. Op. Temp. +6.9V OUTPUT: C2 >10V, Ripple Rated > 300mA @ 100KHz @ Max. Op. Temp. PANASONIC SU GENERAL PURPOSE SERIES: C10, C12 & C2 = 220uF, 25V = PANASONIC ECEA1EU221 C11, C13 & C3 = 100uF, 25V = PANASONIC ECEA1EU101 10 - C12 + 220uF 25V C6 = 0.1uF 250Vac X2-Saftey Cap 1 VR1 P6KE200A PROPERLY SIZED HEAT SINK SOURCE D3 MUR120 (UF4002) 4 3 C5 47uF 6 R1 6.2 KELVIN CONNECT CONTROL C7 & C8 = 250Vac Y-SAFTEY CAPACITORS EMI FILTER C7 2.2nF C8 2.2nF R3 18.7K 1% C R4 10.7K 1% -15Vdc @ 800mA +6.9Vdc @ 300mA C3 100uF 25V + 6.9V RTN R2 470 SOFT START Css + 4.7uF 1 1/2 OF U3 A 2 SEC #1 T1 TSD-1432 C11 100uF 25V L2 VTP-01001 10uH @ 1.0A C2 + 220uF 25V 5 E + L3 VTP-01001 10uH @ 1.0A 7 C4 0.1uF BIAS + DRAIN D4 MUR120 D2 1N4148 4 +/- 15V RTN C10 + 220uF 25V 8 2 C 1/2 OF U3 C13 100uF 25V SEC #2 PRI D1 MUR160 (BYV26C) U1 POWER INT. PWR-TOP224Y +15Vdc @ 800mA 9 CLAMP NETWORK U3 NEC PS2501-1 L4 VTP-01001 + 10uH @ 1.0A 1 U2 C TL431 R A R5 39 1/4W C9 0.1uF 8 6 HIGH VOLTAGE RETURN P Premier M Magnetics Inc. "INNOVATORS IN MAGNETICS TECHNOLOGY" UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MM DIMENSIONAL TOLERANCES ARE: DECIMALS ANGLES .X + .25 +0 O 30' .XX + .15 DO NOT SCALE DRAWING FLYBACK TRANSFORMER CONTROL DRAWING PREMIER P/N: TSD-1432 REVISION: 01/13/00 DRAWN BY: TOM O'NEIL REF: PWR-TOP224 SCALE: NONE SHEET: 2 OF 6