TSD-2629 - Premier Magnetics

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25 OC
FIGURE 1: SCHEMATIC DIAGRAM
1
PARAMETER
MIN.
SPEC LIMITS
TYP.
PRIMARY INDUCTANCE (1-3)
VOLTAGE = 0.250Vrms
FREQUENCY = 10 KHZ
120
130
MAX.
UNITS
140
HY
PRIMARY#1A
12
2
11
PRIMARY#1B
SECONDARY
HIP OT:
PRIMARY TO SECONDARY
3750
--------
--------
Vrms
3
8
CHECK TURN RATIO PER WDG SPEC
5
7
AUX
6
FIGURE 2: PHYSICAL DIMENSIONS mm (INCHES)
1.835
(46.61)
2.065
(52.45)
WHITE DOT
DENOTES PIN#1
P
M
.787
(20.00)
TYP
TSD-2629
YYWW
1.660
(42.16)
.045 SQ.
(1.14)
.300
(7.62)
.18
(4.6)
1.500
(38.10)
REMOVE PIN 4, 9 & 10
.300
(7.62)
1
6
NOTE1:
A) ALL MATERIALS RATED 130C OR BETTER.
B) MARGIN TAPE FOR 6.0mm MIN CREEPAGE.
C) VARNISH FINISHED ASSEMBLY.
1.500
(38.10)
REV.
01/07/09
12
DESCRIPTION OF CHANGES
ORIGINAL RELEASE
7
1.500
(38.10)
UNLESS OTHERW ISE SPECIFIED
DIMENSIONS ARE IN MM
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ .25
+0 O 30'
.XX + .15
DO NOT SCALE DRAWING
TRANSFORMER CONTROL DRAWING
PREMIER P/N: TSD-2629
REVISION: 01/07/09
DRAWN BY: PETER PHAM
REF:
SCALE: NONE
SHEET: 1 OF 2
BY
PP
APPLICATION NOTES
Premier Magnetics TSD-2629 Switch Mode Transformer was designed for use with Power Integrations, Inc.
Premiers PTSD-2629 transformer has been optimized to provide maximum power throughput.
The PWR-TOPXXX series from Power Integrations, Inc. are self contained 132KHz. This series contains all necessary
functions for an off-line switched mode control DC power source. These switching regulators provide a very simple
solution to off-line designs. The inductors and transformer used with the PWR-TOPXXX are critical to the
performance of the circuit. They define the overall efficiency, output power and overall physical size.
Below is a universal input high precision 260 watt application circuit utilizing Power Integrations PWR-TOP261EN
switching regulator in the flyback buck-boost configuration. The component values listed are intended for
reference purposes only. Properly sized heat sinks for the TOP & D3 as well as proper thermal management &
board layout are critical requirements for efficient and reliable operation.
FIGURE 3: TYPICAL APPLICATION CIRCUIT
F1
3.1A
250v
BR1
DF06M
600V, 1A
EMI FILTER
LINE
1
L1
PMCE-0160
16mHY
~
2
+
C1
680 uF
400V
+
110/220Vac
50/60Hz
C6
0.1uF
4
NEUT
3
~
-
C6 = 0.1uF 250Vac
X2-Saftey Cap
D3
MBR20100CT
CLAMP
NETWORK
L2
VTP-02007
20uH @ 7.0A
PROPERLY SIZED
HEAT SINK
T1
TSD-2629
+57Vdc
@ +4.55A
1
C15
10nF
P6KE200A
5.6K
D1
BYV26D
C8, C9 +
840uF
100V
PRI
R3
232K 1%
+
R4
10.70K 1%
SEC
U1
POWER INT.
TOP227Y
RTN
R2
1.33K
5
19.6M
C10
470uF
75V
3
D2
1N4148
PROPERLY SIZED
HEAT SINK
+
5.2M
BIAS
C7
0.1uF
6
L
D
TOP261EN
S
X
U3
NEC2501-H
C
6.81
F
1 U2
C TL431
R
6.98K
+
47uF
A
C7
15nF
8
6
HIGH VOLTAGE RETURN
UNLESS OTHERW ISE SPECIFIED
DIMENSIONS ARE IN MM
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ .25
+0 O 30'
.XX + .15
DO NOT SCALE DRAWING
TRANSFORMER CONTROL DRAWING
PREMIER P/N: TSD-2629
REVISION: 01/07/09
DRAWN BY: PETER PHAM
REF:
SCALE: NONE
SHEET: 2 OF 2