DIESEL GENERATOR SET WATER CHARGE-AIR COOLING 1140kVA/50 Hz/Standby (Fuel-Optimized) 380 - 415V Optional equipment shown. Standard equipment may vary. BENEFITS // // // Low installation costs Best fuel consumption values Long maintenance intervals // // // Best-in-class reliability and availability Lifting vertically or with diagonal pull Compact design SYSTEM RATINGS➀ Standby DS01140D5S DS01140D5S DS01140D5S Voltage (L-L) Phase PF Hz kW kVA Amps Generator model Temp rise Connection 380V 3 0.8 50 904 1130 1717 575RSL7074 150 °C/40 °C 6 LEAD HI WYE 400V 3 0.8 50 912 1140 1645 575RSL7074 150 °C/40 °C 6 LEAD HI WYE 415V 3 0.8 50 840 1050 1461 575RSL7074 150 °C/40 °C 6 LEAD HI WYE ➀ Power available up to 40°C/400 m 2 / // / 50 Hz 1140 kVA CERTIFICATIONS AND STANDARDS Engine-generator set is designed and manufactured in facilities certified to standards ISO 9001:2008 and ISO 14001:2004 // Performance Assurance Certification (PAC) - Engine-generator set tested according to ISO 8528-5 for transient response - Verified product design, quality and performance integrity - All engine systems are type and factory tested // // Power Rating - Permissible average power output during 24 hours of operation up to 85% // Generator STANDARD EQUIPMENT➀ // Engine Air filters Oil pump for draining Full flow oil filters Closed crankcase ventilation Jacket water pump Thermostats Exhaust manifold – dry Belt driven radiator fan Electric starting motor – 24V Governor – electronic isochronous Base – formed steel SAE flywheel & bell housing Charging alternator Flexible fuel connectors Flexible exhaust connection NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor VDE 0530, IEC 60034-1, BS4999, BS5000, CSA22.2-100, AS 1361 Sustained short circuit current of up to 250% of the rated current for up to 10 seconds Self-ventilated and drip-proof IP23 Superior voltage waveform Digital, volts-per-hertz regulator No load to full load regulation Brushless alternator with brushless pilot exciter 4 Pole, rotating field 150 °C maximum standby temperature rise Heavy duty shielded ball bearings with a minimum B-10 life of 40,000 hrs Flexible coupling Full amortisseur windings 3-phase voltage sensing ±0.25% voltage regulation 100% of rated load – one step according to NFPA 110 3% maximum harmonic content ➀ Represents standard product only. Consult Factory/MTU Onsite Energy distributor for additional configurations. 3 / // / 50 Hz 1140 kVA STANDARD FEATURES➀ // // // // // // The engine-generator set complies to G3 Engine generator set tested according to ISO 8528-5 for transient response Accepts rated load in one step as per NFPA 110 All engine-generator sets are type and factory tested MTU Onsite Energy is a single source supplier Global product support // // 16V2000 diesel engine (31,84 Liter (1943 cu inch) displacement; 4-stroke) Engine-generator resiliently mounted Complete range of accessories Brushless, rotating field generator (PMG excitation; 250% short circuit capability; 2/3 pitch stator windings) Complete system metering LCD display // Fuel Consumption➁ // // // // APPLICATION DATA // Engine Manufacturer Model Type Arrangement Displacement: L (cu inch) Bore: mm (inch) Stroke: mm (inch) Compression ratio Rated speed rpm Engine Governor Max power: kWm (bhp) Speed regulation Air filter // MTU 16V2000G65TB 4-Stroke 16-V 1.99 (121) 130 (5.1) 150 (5.9) 16:1 1500 Electronic isochronous 975 (1307) ±0.25% Dry Lube Oil Capacity 102 (27) Electrical Electric Volts DC Cold cranking amps under -17.8 °C (0 °F) // // 24 1000 Water pump capacity: l/min (gpm) Heat rejection to coolant: kW (BTUM) Heat rejection to after cooler: kW (BTUM) Heat radiated to ambient: kW (BTUM) Engine coolant capacity: l (gal) // // l/hr 234 172 116 g/kwh 199 195 198 667 (176) 395 (22,463) 225 (12,796) 45 (2,559) 130 (34) Air Requirements➂ 72 (2540) Exhaust System Gas temp. (stack): °C (°F) Gas volume flow temp: m3/min (SCFM) Maximum allowable back pressure: kPA Fuel System Fuel supply connection size Fuel return connection size Maximum fuel lift: m (ft) Recommended fuel Total fuel flow: l/hr (gal/hr) gal/hr 62 45 31 Cooling/Radiator System Aspirating: m3/min (SCFM) Total oil system: l (gal) // At 100% of power rating: At 75% of power rating: At 50% of power rating: M22x1,5 - 60°/Male M12x1,5 - 60°/Male 5 (16) see MTU fluids & lubrication spec. 600 (159) ➀ Represents standard product only. Consult Factory/MTU Onsite Energy distributor for additional configurations. ➁ Values in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml. ➂ Air density = 1.184 kg/m3 (0.0739 lbm/ft3) 565 (1049) 198 (6991) 8.5 4 / // / 50 Hz 1140 kVA WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based an standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unic specific template drawings. System Open Power Unit (OPU) Dimensions (L x W x H) 4100 x 1750 x 1809 mm (161.4 x 69 x 71.2 inch) Weight (dry/less tank) 5945 kg (13,106 lbs) Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific engine-generator set. SOUND DATA // Consult your local MTU Onsite Energy distributor for sound data. EMISSIONS DATA // Consult your local MTU Onsite Energy distributor for emissions data. RATING DEFINITIONS AND CONDITIONS Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capability for this rating. Ratings are in accordance with ISO 8528-1, ISO3046-1, BS5514, AS 2789 and DIN6271. // Deration factor: Altitude: Consult your local MTU Onsite Energy distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy distributor for temperature derations. Materials and specifications subject to change without notice. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com Subject to change. | 3236681 | Edition 01/14 | ENC 2014-01. //