enclosure and sound data sheet - diesel

ENCLOSURE AND SOUND DATA SHEET - DIESEL
650-2,000 kW Standby / 615-1,800 kW Prime
1,250-2,000 Data Center Continuous Power (DCCP)
ENCLOSURE LEVEL IDENTIFICATION
Weather Proof
Weather proof enclosure constructed of heavy gauge steel or aluminum with fixed
Enclosure (WPE)
storm proof panels. Enclosure consists of a bolted and welded construction with
factory-mounted external muffler or internal muffler where applicable. Hinged,
lockable double-door access on both sides of the enclosure.
Weather Proof
Weather proof enclosure with UL 94 HF-1 compliant, 1.5" thick sound attenuated
(WPE) with Sound
foam insulation installed inside enclosure walls.
Attenuation Kit
Ultra Quiet Enclosure Weather proof foamed enclosure with additional air intake and exhaust scoops for
(UQE)
redirecting noise and air flow upward.
CERTIFICATIONS AND STANDARDS
• UL 2200
• CSA
• ISO 9001:2008
STANDARD FEATURES FOR ALL LEVELS
• Heavy material construction
- Steel Enclosure: 14 gauge or greater
- Aluminum Enclosure: 0.09” thick or greater
• Serviceability access
- Double door access gives ease of serviceability
to all components
• Rain shroud and rain cap
• Rodent barriers
• Scoop access panels
• Hardware
- Powder coated hinges with stainless steel pins
- Key-lockable and pad-lockable powder coated
door handles
• Finish Paint: ANSI 61 Grey standard
- Custom colors available upon request
• External silencer (Industrial grade or better)
- Stainless steel flexible exhaust connections
(where applicable)
// Page 1 of 3
ENCLOSURE AND SOUND DATA SHEET - DIESEL
650-2,000 kW Standby / 615-1,800 kW Prime
1,250-2,000 Data Center Continuous Power (DCCP)
Ultra Quiet Enclosure (UQE)
Weather Proof Enclosure (WPE)
OPTIONAL FEATURES
•
•
•
•
Door restraints
AC or DC light package
Motorized / gravity louvers (where available)
Internal silencer (Critical grade or better)
- Insulated mufflers
- Stainless steel flexible exhaust connections
(where applicable)
• For other custom options, please consult
factory.
// Page 2 of 3
ENCLOSURE AND SOUND DATA SHEET - DIESEL
650-2,000 kW Standby / 615-1,800 kW Prime
1,250-2,000 Data Center Continuous Power (DCCP)
SOUND RATINGS dB(A) AT 7 METERS
Model
Power Node
Weather
Proof
Enclosure
(WPE)
Standby
MTU 12V2000 DS650
MTU 12V2000 DS750
MTU 12V2000 DS800
MTU 16V2000 DS900
MTU 16V2000 DS1000
MTU 12V4000 DS1250*
MTU 12V4000 DS1500*
MTU 12V4000 DS1750*
MTU 16V4000 DS2000*
MTU 12V2000 DS650
MTU 12V2000 DS750
MTU 12V2000 DS800
MTU 16V2000 DS900
MTU 16V2000 DS1000
MTU 12V4000 DS1250
MTU 12V4000 DS1500
MTU 12V4000 DS1750
MTU 16V4000 DS2000
650 kW
750 kW
800 kW
900 kW
1,000 kW
1,250 kW
1,500 kW
1,750 kW
2,000 kW
615 kW
680 kW
725 kW
800 kW
900 kW
1,125 kW
1,400 kW
1,600 kW
1,800 kW
89
89
86.1
89.5
93
C/F
C/F
C/F
C/F
C/F
C/F
86
C/F
C/F
C/F
C/F
C/F
C/F
* Includes
Data Center
Continuous
Power (DCCP)
ratings
Prime
Weather
Proof
Enclosure
with Sound
Attenuation
Kit (WPE
w/Sound
Attenuation
Kit)
86.4
86.4
82
86.5
91.7
88
89.2
90.2
91.8
C/F
C/F
82.1
C/F
C/F
C/F
C/F
C/F
C/F
Ultra Quiet
Enclosure
(UQE)
71.9
71.9
76
80.5
81.5
75.9
76.2
77.2
84
C/F
C/F
C/F
C/F
C/F
C/F
C/F
C/F
C/F
NOTE:
• Aluminum enclosure sound levels are approximately 2 dB(A) higher than listed sound levels for steel
enclosures
• Sound pressure levels subject to instrumentation, measurement, installation, and generator set variability
• Sound power levels per ISO 8528-10 and ANSI S1.13-2005
• Sound data measured with:
- Full-rated load
- Standard radiator package
- Infinite exhaust connection
Refer to the MTU Business Portal Acoustics Data for exhaust noise ratings.
C/F = Consult Factory
© MTU Onsite Energy. Subject to alteration due to technological advances. 2015-01