UWR-5/1000-D24-C

UWR Models
www.murata-ps.com
Single Output, Miniature, 1" x 1", 5 Watt, DC/DC Converters
OBSOLETE PRODUCT
FEATURES
PRODUCT OVERVIEW

Small size, 1" x 1" x 0.45"
The migration to distributed power is accelerating. The critical need for accurate voltages, tight
regulation and rapid transient response is propelling the move to power processing at the "point-ofuse" with low-power DC/DC converters physically
located right at their loads.
DATEL’s miniature, full featured, 5 Watt UWR
Models were specifically designed for today’s
demanding distributed power architectures in
aerospace, marine, telecom and computer applications. The converters' low cost, small size (1" x
1" x 0.45") and full 5 Watt output capability give
system architects unprecedented design and layout
flexibility.
Occupying less than 0.5in3 total volume, these
extremely compact, fully regulated and isolated
(1000Vdc guaranteed) modules are available with
either 5, 12 or 15 Volt outputs. Input voltage ranges
are either 18-36 Volts ("D24" models) or 36-72
Volts ("D48" models).

Full 5 Watts output power

No external components required

Drop-in replacements for many standard,
2" x 1" DC/DCs

Wide input voltage ranges:
18-36V or 36-72V

5, 12, or 15V outputs

Guaranteed efficiencies to 80%

Fully regulated and isolated
(1000Vdc guaranteed)

Output overvoltage protection and current
limiting

–25 to +95°C operating temperature

Shielded cases (5 sides)

UL 1950, CSA 22.2 No. 234, IEC 950
Although their overall size is 50-75% smaller
than many similarly rated power modules, these
1" x 1" UWR Models are exact, drop-in, pin-forpin replacements for many standard 2" x 1" and
2" x 2", 5 Watt modules. They achieve their small
size and low cost by exploiting a novel feedback
approach that does not depend upon traditional
optocoupler techniques.
All models are 5-side shielded and have a
non-conductive baseplate that permits pc-card
runs to be placed beneath the package. Units
are assembled using high-speed automated
SMT techniques and are fully encapsulated with
thermally conductive potting compound. Every unit
is electrically tested before and after encapsulation,
100% burned-in under full load, hi-pot tested, and
final-electrical tested prior to shipment. Every unit
meets DATEL’s traditional high standards for quality
and long-term reliability.

Modifications and customs for OEM's
+VIN
*
PWM
+VOUT
COMMON
* "D24" models only
Typical topology is shown
–VIN
Figure 1. Simplified Block Diagram
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
UWR5W.D02 Page 1 of 5
UWR Models
Single Output, Miniature, 1" x 1", 5 Watt, DC/DC Converters
E
T
E
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀
OL
Input
Regulation (Max.)
Model
Vout
(Volts)
Iout
(mA, max)
Ripple/Noise ➁
(mVp-p, Max.)
Line
Load ➂
Vin Nom.
(Volts)
Range
(Volts)
Iin➃
(mA, Max.)
Efficiency
(Min.)
Package
(Case, Pinout)
UWR-5/1000-D24-C
5
1000
120
±2%
±2%
24
18-36
25/282
75%
C7, P3
UWR-5/1000-D48-C
5
1000
120
±2%
±2%
48
36-72
25/141
75%
C7, P3
UWR-12/420-D24-C
12
420
150
±2%
±2%
24
18-36
25/265
80%
C7, P3
UWR-12/420-D48-C
12
420
150
±2%
±2%
48
36-72
25/133
80%
C7, P3
UWR-15/335-D24-C
15
335
150
±2%
±2%
24
18-36
25/264
80%
C7, P3
UWR-15/335-D48-C
15
335
150
±2%
±2%
48
36-72
25/134
79%
C7, P3
➀ Typical at TA = +25°C under nominal line voltage and full-load conditions unless otherwise noted.
➁ Ripple/Noise (R/N) measured over a 20MHz bandwidth.
➂ 20% to 100% load.
PART NUMBER STRUCTURE
➃ Nominal line voltage, no-load/full-load conditions.
➄ RoHS-6 hazardous substance compliance does not claim EU exemption 7b (lead in solder).
MECHANICAL SPECIFICATIONS
1.00
(25.40)
U WR - 15 / 335 - D24 - C
METAL CASE
RoHS-6 hazardous
substance compliant*
Output Configuration:
U = Unipolar
0.45
(11.43)
Case C7
Input Voltage Range:
D24 = 18-36 Volts (24V nominal)
D48 = 36-72 Volts (48V nominal)
Wide Range Input
INSULATED BASE
0.040 ±0.002 DIA.
(1.016 ±0.051)
0.20 MIN.
(5.08)
Maximum Output Current
in mA
* Contact Murata Power Solutions
(Datel) for availability.
Nominal Output Voltage
5, 12 or 15 Volts
0.800
(20.32)
0.10
(2.54)
3
0.100
(2.54)
0.400
(10.16)
1
1.00
0.800
(20.32) (25.40)
4
2
5
0.200
(5.08)
6
BOTTOM VIEW
0.200
(5.08)
0.10
(2.54)
Notes:
TEMPERATURE DERATING
For "D24" models, the case
is connected to pin 2 (–VIN).
5
4. 5
For "D48" models, the case
is connected to pin 1 (+VIN).
4
3. 5
Output Power (Watts)
O
BS
Output
3
INPUT/OUTPUT CONNECTIONS
Pin
Function P3
2. 5
1
2
1. 5
1
0. 5
Dimensions are in inches (mm shown for ref. only).
Third Angle Projection
+Vin
2
–Vin
3
+Vout
4
No Pin
5
No Pin
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 2˚
6
Common
Components are shown for reference only.
0
–25
0
35
40
45
50
55
60
65
70
75
80
85
90
95
Ambient Temperature (°C)
www.murata-ps.com/support
UWR5W.D02 Page 2 of 5
UWR Models
Single Output, Miniature, 1" x 1", 5 Watt, DC/DC Converters
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀
ABSOLUTE MAXIMUM RATINGS
INPUT
Input Voltage Range:
"D24" Models
"D48" Models
18-36 Volts (24V nominal)
36-72 Volts (48V nominal)
Input Current
See Ordering Guide
Input Filter Type ➁
LC on "D24" models
C on "D48" models
Reverse-Polarity Protection
Yes (Instantaneous, 6A maximum)
OUTPUT
VOUT Accuracy (50% load):
5V Outputs
12/15V Outputs
±1.5%, maximum
±1%, maximum
Temperature Coefficient
±0.02% per °C
Ripple/Noise (20MHz BW) ➁
See Ordering Guide
Line Regulation
See Ordering Guide
Load Regulation
See Ordering Guide
Efficiency
See Ordering Guide
Isolation Voltage ➂
1000Vdc, minimum
Current Limiting
Auto-recovery
Overvoltage Protection
Input Voltage:
"D24" Models
"D48" Models
40 Volts
80 Volts
Input Reverse-Polarity Protection
Output Overvoltage Protection:
5V Outputs
12V Outputs
15V Outputs
Output Current
Current must be < 6A. Brief
duration only. Fusing recommended.
6.8 Volts, limited duration
15 Volts, limited duration
18 Volts, limited duration
Current limited. Max. current and
short-circuit duration are model
dependent.
Storage Temperature
–55 to +125°C
Lead Temperature (soldering, 10 sec.)
+300°C
These are stress ratings. Exposure of devices to greater than any of these conditions
may adversely affect long-term reliability. Proper operation under conditions other than
those listed in the Performance/Functional Specifications Table is not implied.
Zener/transorb clamp
DYNAMIC CHARACTERISTICS
Transient Response (50% load step)
500µsec max. to ±2% of final value
Switching Frequency
170kHz (±10kHz)
ENVIRONMENTAL
Operating Temperature (Ambient): ➃
Without Derating
With Derating
–25 to +60°C
to +95°C (See Derating Curve)
TECHNICAL NOTES
Floating Outputs
Since these are isolated DC/DC converters, their outputs are "floating."
Users may ground either the Common (pin 6) for normal usage or the positive side (+Output, pin 3) to effectively reverse the output polarity.
Storage Temperature
–55 to +125°C
Filtering and Noise Reduction
Flammability
UL94V-0
All UWR 5 Watt DC/DC Converters achieve their rated ripple and noise
specifications without the use of external input/output capacitors. In critical applications, input/output ripple and noise may be further reduced by
installing low-ESR, tantalum or electrolytic capacitors across the input
and/or output terminals. The capacitors should be located as close to the
power converters as possible. Typical values are listed below. In many
applications, using values greater than those listed will yield better results.
PHYSICAL
Dimensions
1" x 1" x 0.45" (25.4 x 25.4 x 11.4mm)
Shielding
5-sided
Case Connection:
"D24" Models
"D48" Models
Pin 2 (–VIN)
Pin 1 (+VIN)
Case Material
Corrosion resistant steel with
non-conductive, powder coat matte black
finish and plastic baseplate
Pin Material
Gold plate over copper alloy
Weight
0.7 ounces (20 grams)
➀ These power converters require a minimum 20% loading to maintain specified regulation.
Operation under no-load conditions will not damage these devices; however
they may not meet all listed specifications.
To Reduce Input Ripple
"D24" Models
"D48" Models
20µF, 50V
10µF, 100V
To Reduce Output Ripple
5V Outputs
12/15V Outputs
47µF, 10V, Low ESR
33µF, 20V, Low ESR
Input Fusing
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. For DATEL UWR
5 Watt DC/DC Converters, you should use fast-blow type fuses with values
no greater than 0.5A.
www.murata-ps.com/support
UWR5W.D02 Page 3 of 5
UWR Models
Single Output, Miniature, 1" x 1", 5 Watt, DC/DC Converters
TYPICAL PERFORMANCE CURVES (TA = +25°C)
The performance curves below were derived from actual test data for a single model number (UWR-5/1000-D24). Since all devices in this Series have the same circuit topology, the
performance curves are representative of all devices.
EFFICIENCY VS. INPUT VOLTAGE AND OUTPUT LOAD
Efficiency vs. Output Load
(VIN = nominal = 24V. Guaranteed efficiency at full load = 75%)
81
82
80
80
Efficiency (%)
Efficiency (%)
Efficiency vs. Input Voltage
(Full-load conditions. Guaranteed efficiency = 75% at VIN = 24V )
79
78
77
76
78
76
74
72
75
70
18
21
24
27
30
33
36
0.2
0.4
0.6
1.0
Output Current (Amps)
Input Voltage (Volts)
LINE REGULATION
LOAD REGULATION
Output Voltage vs. Output Load
(VIN = nominal = 24V. Nominal VOUT = 5V)
Output Voltage vs.Input Voltage
(Full-load conditions. Nominal VOUT = 5V)
5.15
5.06
Output Voltage (Volts)
Output Voltage (Volts)
0.8
5.10
5.05
5.00
4.95
4.90
4.85
18
21
24
27
30
Input Voltage (Volts)
33
36
5.04
5.02
5.00
4.98
4.96
4.94
0.2
0.4
0.6
0.8
1.0
Output Current (Amps)
www.murata-ps.com/support
UWR5W.D02 Page 4 of 5
UWR Models
Single Output, Miniature, 1" x 1", 5 Watt, DC/DC Converters
CUSTOM CAPABILITIES
EMI RADIATED EMISSIONS
DATEL’s world-class design, development and manufacturing team stands
ready to work with you to deliver the exact power converter you need for
your demanding, large volume, OEM applications. And ... we’ll do it on
time and within budget!
If you’re designing with EMC in mind, please note that all of DATEL’s UWR
5 Watt DC/DC Converters have been characterized for radiated and
conducted emissions in our new EMI/EMC laboratory. Testing is conducted
in an EMCO 5305 GTEM test cell utilizing EMCO automated EMC test
software. Radiated emissions are tested to the limits of FCC Part 15, Class
B and CISPR 22 (EN 55022), Class B. Correlation to other specifications
can be supplied upon request. Radiated emissions plots to FCC and CISPR
22 for model UWR-5/1000-D24 appear below. Its performance is typical of
all models in the Family.
Our experienced applications and design staffs; quick-turn prototype
capability; highly automated, SMT assembly facilities; and in-line SPC
quality-control techniques combine to give us the unique ability to design
and deliver any quantity of power converters to the highest standards of
quality and reliability.
We have compiled a large library of DC/DC designs that are currently used
in a variety of telecom, medical, computer, railway, aerospace and industrial applications. We may already have the converter you need.
UWR-5/1000-D24 Radiated Emissions
FCC Part 15 Class B, 3 Meters
Converter Output = 5Vdc @ 800mA
Contact us. Our goal is to provide you the highest-quality, most costeffective power converters available.
80
70
Radiated Emissions (dBµV/M)
60
FCC Class B Limit
50
40
30
20
10
0
Radiated Emissions
–10
–20
1000
100
Frequency (MHz)
UWR-5/1000-D24 Radiated Emissions
EN 55022 Class B, 10 Meters
Converter Output = 5Vdc @ 800mA
80
70
Radiated Emissions (dBµV/M)
60
EN 55022 Class B Limit
50
40
30
20
10
0
–10
Radiated Emissions
–20
1000
100
Frequency (MHz)
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2013 Murata Power Solutions, Inc.
www.murata-ps.com/support