UWR Models www.murata-ps.com Single Output, Miniature, 1" x 1", 5 Watt, DC/DC Converters OBSOLETE PRODUCT FEATURES PRODUCT OVERVIEW Small size, 1" x 1" x 0.45" The migration to distributed power is accelerating. The critical need for accurate voltages, tight regulation and rapid transient response is propelling the move to power processing at the "point-ofuse" with low-power DC/DC converters physically located right at their loads. DATEL’s miniature, full featured, 5 Watt UWR Models were specifically designed for today’s demanding distributed power architectures in aerospace, marine, telecom and computer applications. The converters' low cost, small size (1" x 1" x 0.45") and full 5 Watt output capability give system architects unprecedented design and layout flexibility. Occupying less than 0.5in3 total volume, these extremely compact, fully regulated and isolated (1000Vdc guaranteed) modules are available with either 5, 12 or 15 Volt outputs. Input voltage ranges are either 18-36 Volts ("D24" models) or 36-72 Volts ("D48" models). Full 5 Watts output power No external components required Drop-in replacements for many standard, 2" x 1" DC/DCs Wide input voltage ranges: 18-36V or 36-72V 5, 12, or 15V outputs Guaranteed efficiencies to 80% Fully regulated and isolated (1000Vdc guaranteed) Output overvoltage protection and current limiting –25 to +95°C operating temperature Shielded cases (5 sides) UL 1950, CSA 22.2 No. 234, IEC 950 Although their overall size is 50-75% smaller than many similarly rated power modules, these 1" x 1" UWR Models are exact, drop-in, pin-forpin replacements for many standard 2" x 1" and 2" x 2", 5 Watt modules. They achieve their small size and low cost by exploiting a novel feedback approach that does not depend upon traditional optocoupler techniques. All models are 5-side shielded and have a non-conductive baseplate that permits pc-card runs to be placed beneath the package. Units are assembled using high-speed automated SMT techniques and are fully encapsulated with thermally conductive potting compound. Every unit is electrically tested before and after encapsulation, 100% burned-in under full load, hi-pot tested, and final-electrical tested prior to shipment. Every unit meets DATEL’s traditional high standards for quality and long-term reliability. Modifications and customs for OEM's +VIN * PWM +VOUT COMMON * "D24" models only Typical topology is shown –VIN Figure 1. Simplified Block Diagram For full details go to www.murata-ps.com/rohs www.murata-ps.com/support UWR5W.D02 Page 1 of 5 UWR Models Single Output, Miniature, 1" x 1", 5 Watt, DC/DC Converters E T E PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀ OL Input Regulation (Max.) Model Vout (Volts) Iout (mA, max) Ripple/Noise ➁ (mVp-p, Max.) Line Load ➂ Vin Nom. (Volts) Range (Volts) Iin➃ (mA, Max.) Efficiency (Min.) Package (Case, Pinout) UWR-5/1000-D24-C 5 1000 120 ±2% ±2% 24 18-36 25/282 75% C7, P3 UWR-5/1000-D48-C 5 1000 120 ±2% ±2% 48 36-72 25/141 75% C7, P3 UWR-12/420-D24-C 12 420 150 ±2% ±2% 24 18-36 25/265 80% C7, P3 UWR-12/420-D48-C 12 420 150 ±2% ±2% 48 36-72 25/133 80% C7, P3 UWR-15/335-D24-C 15 335 150 ±2% ±2% 24 18-36 25/264 80% C7, P3 UWR-15/335-D48-C 15 335 150 ±2% ±2% 48 36-72 25/134 79% C7, P3 ➀ Typical at TA = +25°C under nominal line voltage and full-load conditions unless otherwise noted. ➁ Ripple/Noise (R/N) measured over a 20MHz bandwidth. ➂ 20% to 100% load. PART NUMBER STRUCTURE ➃ Nominal line voltage, no-load/full-load conditions. ➄ RoHS-6 hazardous substance compliance does not claim EU exemption 7b (lead in solder). MECHANICAL SPECIFICATIONS 1.00 (25.40) U WR - 15 / 335 - D24 - C METAL CASE RoHS-6 hazardous substance compliant* Output Configuration: U = Unipolar 0.45 (11.43) Case C7 Input Voltage Range: D24 = 18-36 Volts (24V nominal) D48 = 36-72 Volts (48V nominal) Wide Range Input INSULATED BASE 0.040 ±0.002 DIA. (1.016 ±0.051) 0.20 MIN. (5.08) Maximum Output Current in mA * Contact Murata Power Solutions (Datel) for availability. Nominal Output Voltage 5, 12 or 15 Volts 0.800 (20.32) 0.10 (2.54) 3 0.100 (2.54) 0.400 (10.16) 1 1.00 0.800 (20.32) (25.40) 4 2 5 0.200 (5.08) 6 BOTTOM VIEW 0.200 (5.08) 0.10 (2.54) Notes: TEMPERATURE DERATING For "D24" models, the case is connected to pin 2 (–VIN). 5 4. 5 For "D48" models, the case is connected to pin 1 (+VIN). 4 3. 5 Output Power (Watts) O BS Output 3 INPUT/OUTPUT CONNECTIONS Pin Function P3 2. 5 1 2 1. 5 1 0. 5 Dimensions are in inches (mm shown for ref. only). Third Angle Projection +Vin 2 –Vin 3 +Vout 4 No Pin 5 No Pin Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ 6 Common Components are shown for reference only. 0 –25 0 35 40 45 50 55 60 65 70 75 80 85 90 95 Ambient Temperature (°C) www.murata-ps.com/support UWR5W.D02 Page 2 of 5 UWR Models Single Output, Miniature, 1" x 1", 5 Watt, DC/DC Converters Performance/Functional Specifications Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀ ABSOLUTE MAXIMUM RATINGS INPUT Input Voltage Range: "D24" Models "D48" Models 18-36 Volts (24V nominal) 36-72 Volts (48V nominal) Input Current See Ordering Guide Input Filter Type ➁ LC on "D24" models C on "D48" models Reverse-Polarity Protection Yes (Instantaneous, 6A maximum) OUTPUT VOUT Accuracy (50% load): 5V Outputs 12/15V Outputs ±1.5%, maximum ±1%, maximum Temperature Coefficient ±0.02% per °C Ripple/Noise (20MHz BW) ➁ See Ordering Guide Line Regulation See Ordering Guide Load Regulation See Ordering Guide Efficiency See Ordering Guide Isolation Voltage ➂ 1000Vdc, minimum Current Limiting Auto-recovery Overvoltage Protection Input Voltage: "D24" Models "D48" Models 40 Volts 80 Volts Input Reverse-Polarity Protection Output Overvoltage Protection: 5V Outputs 12V Outputs 15V Outputs Output Current Current must be < 6A. Brief duration only. Fusing recommended. 6.8 Volts, limited duration 15 Volts, limited duration 18 Volts, limited duration Current limited. Max. current and short-circuit duration are model dependent. Storage Temperature –55 to +125°C Lead Temperature (soldering, 10 sec.) +300°C These are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied. Zener/transorb clamp DYNAMIC CHARACTERISTICS Transient Response (50% load step) 500µsec max. to ±2% of final value Switching Frequency 170kHz (±10kHz) ENVIRONMENTAL Operating Temperature (Ambient): ➃ Without Derating With Derating –25 to +60°C to +95°C (See Derating Curve) TECHNICAL NOTES Floating Outputs Since these are isolated DC/DC converters, their outputs are "floating." Users may ground either the Common (pin 6) for normal usage or the positive side (+Output, pin 3) to effectively reverse the output polarity. Storage Temperature –55 to +125°C Filtering and Noise Reduction Flammability UL94V-0 All UWR 5 Watt DC/DC Converters achieve their rated ripple and noise specifications without the use of external input/output capacitors. In critical applications, input/output ripple and noise may be further reduced by installing low-ESR, tantalum or electrolytic capacitors across the input and/or output terminals. The capacitors should be located as close to the power converters as possible. Typical values are listed below. In many applications, using values greater than those listed will yield better results. PHYSICAL Dimensions 1" x 1" x 0.45" (25.4 x 25.4 x 11.4mm) Shielding 5-sided Case Connection: "D24" Models "D48" Models Pin 2 (–VIN) Pin 1 (+VIN) Case Material Corrosion resistant steel with non-conductive, powder coat matte black finish and plastic baseplate Pin Material Gold plate over copper alloy Weight 0.7 ounces (20 grams) ➀ These power converters require a minimum 20% loading to maintain specified regulation. Operation under no-load conditions will not damage these devices; however they may not meet all listed specifications. To Reduce Input Ripple "D24" Models "D48" Models 20µF, 50V 10µF, 100V To Reduce Output Ripple 5V Outputs 12/15V Outputs 47µF, 10V, Low ESR 33µF, 20V, Low ESR Input Fusing Certain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. For DATEL UWR 5 Watt DC/DC Converters, you should use fast-blow type fuses with values no greater than 0.5A. www.murata-ps.com/support UWR5W.D02 Page 3 of 5 UWR Models Single Output, Miniature, 1" x 1", 5 Watt, DC/DC Converters TYPICAL PERFORMANCE CURVES (TA = +25°C) The performance curves below were derived from actual test data for a single model number (UWR-5/1000-D24). Since all devices in this Series have the same circuit topology, the performance curves are representative of all devices. EFFICIENCY VS. INPUT VOLTAGE AND OUTPUT LOAD Efficiency vs. Output Load (VIN = nominal = 24V. Guaranteed efficiency at full load = 75%) 81 82 80 80 Efficiency (%) Efficiency (%) Efficiency vs. Input Voltage (Full-load conditions. Guaranteed efficiency = 75% at VIN = 24V ) 79 78 77 76 78 76 74 72 75 70 18 21 24 27 30 33 36 0.2 0.4 0.6 1.0 Output Current (Amps) Input Voltage (Volts) LINE REGULATION LOAD REGULATION Output Voltage vs. Output Load (VIN = nominal = 24V. Nominal VOUT = 5V) Output Voltage vs.Input Voltage (Full-load conditions. Nominal VOUT = 5V) 5.15 5.06 Output Voltage (Volts) Output Voltage (Volts) 0.8 5.10 5.05 5.00 4.95 4.90 4.85 18 21 24 27 30 Input Voltage (Volts) 33 36 5.04 5.02 5.00 4.98 4.96 4.94 0.2 0.4 0.6 0.8 1.0 Output Current (Amps) www.murata-ps.com/support UWR5W.D02 Page 4 of 5 UWR Models Single Output, Miniature, 1" x 1", 5 Watt, DC/DC Converters CUSTOM CAPABILITIES EMI RADIATED EMISSIONS DATEL’s world-class design, development and manufacturing team stands ready to work with you to deliver the exact power converter you need for your demanding, large volume, OEM applications. And ... we’ll do it on time and within budget! If you’re designing with EMC in mind, please note that all of DATEL’s UWR 5 Watt DC/DC Converters have been characterized for radiated and conducted emissions in our new EMI/EMC laboratory. Testing is conducted in an EMCO 5305 GTEM test cell utilizing EMCO automated EMC test software. Radiated emissions are tested to the limits of FCC Part 15, Class B and CISPR 22 (EN 55022), Class B. Correlation to other specifications can be supplied upon request. Radiated emissions plots to FCC and CISPR 22 for model UWR-5/1000-D24 appear below. Its performance is typical of all models in the Family. Our experienced applications and design staffs; quick-turn prototype capability; highly automated, SMT assembly facilities; and in-line SPC quality-control techniques combine to give us the unique ability to design and deliver any quantity of power converters to the highest standards of quality and reliability. We have compiled a large library of DC/DC designs that are currently used in a variety of telecom, medical, computer, railway, aerospace and industrial applications. We may already have the converter you need. UWR-5/1000-D24 Radiated Emissions FCC Part 15 Class B, 3 Meters Converter Output = 5Vdc @ 800mA Contact us. Our goal is to provide you the highest-quality, most costeffective power converters available. 80 70 Radiated Emissions (dBµV/M) 60 FCC Class B Limit 50 40 30 20 10 0 Radiated Emissions –10 –20 1000 100 Frequency (MHz) UWR-5/1000-D24 Radiated Emissions EN 55022 Class B, 10 Meters Converter Output = 5Vdc @ 800mA 80 70 Radiated Emissions (dBµV/M) 60 EN 55022 Class B Limit 50 40 30 20 10 0 –10 Radiated Emissions –20 1000 100 Frequency (MHz) Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2013 Murata Power Solutions, Inc. www.murata-ps.com/support UWR5W.D02 Page 5 of 5