1605 Murata Power Solutions

1605C
www.murata-ps.com
Lan-Pak for CSMA/CD Systems
SELECTION GUIDE
Order Code
Turns Ratio
Min.
Primary
Inductance
1605C
1:1
26.0
Max.
Leakage
Inductance
Max.
Inerwinding
Capacitance
Vμs
μH
pF
1.8
0.2
8
Max.
DC Resistance
Min.
ET Constant
Ω
0.2
μH
ABSOLUTE MAXIMUM RATINGS
Operating free air temperature range
0°C to 70°C
Storage temperature range
-60°C to 125°C
FEATURES
Isolation voltage (flash tested for 1 second)
500Vrms
n RoHS compliant
SOLDERING INFORMATION1
n 500Vrms isolation
Peak wave solder temperature, 1.5mm from case
300˚C for 10 seconds
n Industry-standard footprint
Pin finish
Matte Tin
n Compatible with standard networks
n Backward compatible with
Sn/Pb soldering systems
DESCRIPTION
The 1605C is a package of unity-turns-ratio
isolation transformers. The transformers are
designed to have fast rise times with low phase
shift and insertion loss to reduce signal distortion.
The high shunt impedance of these devices
minimises system loading and enables the correct
termination conditions to be accurately defined by
means of resistors. The devices can be used as
network-node isolators in CSMA/CD systems.
All specifications typical at TA=25°C.
1 For further information, please visit www.murata-ps.com/rohs
TECHNICAL NOTES
ISOLATION VOLTAGE
REPEATED HIGH-VOLTAGE ISOLATION TESTING
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’
are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed
to provide electrical isolation, to verify the integrity of that
isolation.
It is well known that repeated high-voltage isolation
testing of a barrier component can actually degrade
isolation capability, to a lesser or greater degree
depending on materials, construction and environment. This series has toroidal isolation transformers,
with no additional insulation between primary and
secondary windings of enameled wire. While parts
can be expected to withstand several times the
stated test voltage, the isolation capability does depend on the wire insulation. Any material, including
this enamel (typically polyurethane) is susceptible
to eventual chemical degradation when subject to
very high applied voltages thus implying that the
number of tests should be strictly limited. We therefore strongly advise against repeated high voltage
isolation testing, but if it is absolutely required, that
the voltage be reduced by 20% from specified test
voltage.
All products in this series are 100% production tested at
their stated isolation voltage.
A question commonly asked is, “What is the continuous
voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals both input
and output should normally be maintained within SELV limits
i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages
and the part should never be used as an element of a safety
isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously
across the isolation barrier; but then the circuitry on both
sides of the barrier must be regarded as operating at an
unsafe voltage and further isolation/insulation systems must
form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements.
This consideration equally applies to agency recognized parts rated for better than functional isolation
where the wire enamel insulation is always supplemented by a further insulation system of physical
spacing or barriers.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KMP_1605C_B05 Page 1 of 2
1605C
Lan-Pak for CSMA/CD Systems
22.50 (0.886)
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
6.86
(0.270)
1605C
PIN CONNECTIONS
XYYWW
PIN CONNECTIONS
16 15 14 13 12 11 10
9
22.50 (0.886)
5.0 Max.
(0.197)
22.50 (0.886)
6.86
(0.270)
6.86
(0.270)
5.0 Max.
(0.197)
1605C4.50 (0.177)
1600C
0.64±0.15
(0.025±0.00008)
XYYWW
2.54 (0.10)
17.78 (0.7)
XYYWW
1
2
3
4
5
6
7
8
0.50±0.05
(0.02±0.002)
TUBE DIMENSIONS
9.6 (0.374)
5.80
4.50 (0.177)
(0.228)
4.50 (0.177)
0.64±0.15
(0.025±0.00008)
2.54 (0.10)
17.78 (0.7)
0.64±0.15
0.50±0.05
(0.025±0.006)
(0.02±0.002)
5.4 (0.213)
0.25±0.05
(0.001±0.002)
8.85 (0.348)
2.54 (0.10)
17.78 (0.7)
0.50±0.05
(0.02±0.002)
0.26±0.05
(0.01±0.002)
13.2
(0.520)
0.5 (0.020)
4.8
(0.189)
14.4 (0.567)
0.25±0.05
All dimensions in mm (inches) ± 0.25(0.001±0.002)
(0.001) unless otherwise stated.
Package weight: 1.7g Typ.
Tube length: 520mm (20.5)
All dimensions in mm (inches) ±0.25 (0.001) unless otherwise stated.
Package quantity: 20
8.65 (0.34)
0.25±0.05
(0.001±0.002)
0.26±0.05
(0.01±0.002)
8.85 (0.348)
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice. © 2011 Murata Power Solutions, Inc.
www.murata-ps.com/support
KMP_1605C_B05 Page 2 of 2