DMU-30ACV Series - Murata Power Solutions

DMU-30ACV Series
www.murata-ps.com
Ruggedized True-rms ac Voltmeters with Daylight
Readable, Auto-Dimming LED Displays
FEATURES

Measures and displays the true-rms value of complex
ac voltages

Three input ranges: 20Vac, 200Vac and 300Vac

Daylight-readable LED display with automatic
brightness adjustment

Moisture & impact resistant package offers
NEMA-4/IP65 protection

Operates from universal 85-264Vac or 110-300Vdc

Input circuit fully isolated from operating
ac power source

47-1kHz input frequency range with crest factors
up to 5
Murata Power Solutions’ DMU-30ACV series of daylight-readable ac voltmeters measure and display the true-rms values of complex ac waveforms. Their large 0.56” (14.2mm)
high super-bright red LED-display is readable in full sunlight. An auto-dimming circuit
automatically adjusts the display brightness for all viewing conditions.
And all DMU-30ACV ac voltmeters are packaged in a plastic package with an integrated
bezel and gasket assembly designed to meet NEMA-4/IP65 for moisture resistance in
outdoor applications.
DMU-30ACV series rms voltmeters are available in a choice of three input ranges:
20Vac (with 0.01V resolution); 200Vac (0.1V resolution); and 300Vac (1V resolution).
Because the input circuitry is electrically isolated from the unit’s operating power source,
these voltmeters can measure ac signals down to zero volts. An input frequency range
of 47-1kHz makes these voltmeters ideal for all ac voltage monitoring applications. And,
unlike conventional average-responding designs, these meters can measure and accurately
display the true-rms value of triangle waves, square waves, or any other irregularly shaped
waveform, with 0.4% full-scale accuracy.
DMU-30ACV series’ miniature size and ruggedized package is perfect for all industrial
and high-reliability instrumentation, alternative power generators, and any other application
which requires precise ac line monitoring in harsh indoor/outdoor environments. Simply
connect the input signal and an 85-264Vac source of operating power to the two rearmounted terminal blocks and the unit is fully operational.
TECHNICAL NOTES
IMPORTANT! To ensure safe and reliable operation, DMU-30ACV ac voltmeters must
be installed and serviced by qualified technical personnel. Contact Murata Power
Solutions / DATEL if there is any doubt regarding installation and/or operation.
1. Measurement Type: DMU-30ACV series ac voltmeters employ a precision rms-to-dc converter and a stable voltage reference to measure and display the rms value of complex ac
waveforms. Crest factors as high as 5 produce minimal additional errors (see Performance Specifications).
CAL
1
2. Wiring: All ac supply and input signal wiring must be adequately rated for the voltages
and currents they will carry, and must comply with any code or application-mandated
requirements pertaining to the user’s specific installation.
BRIGHTNESS
ADJUST
2
1
3. Power Supply Polarity, Fusing, Wiring and Grounding: The power supply inputs (TB1-1
and TB1-2) on DMU-30ACV voltmeters are not polarity sensitive, that is, they have no “AC
LO” or “AC HI” designations. These units do not include or require a connection to earth/
chassis ground. Refer to Figure 1 for a typical wiring diagram.
2
TB1
TB2
+
–
REAR VIEW
85-264Vac
Power Source
Input Signal
Figure 1. DMU-30ACV wiring diagram
Wires specified in the Functional Specifications section must be used for making connections to DMU-30ACV series voltmeters. All power-supply and load wiring must be rated
for the supply voltages and currents they will conduct and must comply with any code or
application-mandated requirements pertaining to the user’s specific installation.
DMU-30ACV voltmeters are not internally fused. Terminal block TB1 is to be used only
for powering the power meter’s internal circuitry; it must not be used to supply power
to external loads. The supply wires feeding these power meters must be fused with a
0.5A/250V time delay/time lag fuse, in accordance with applicable regulatory codes.
Wire insulation must be stripped to within ±10% of the stated dimensions, and wires
should be inserted into TB1 such that their insulation is not pinched by the screw terminal.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MPM_DMU-30ACV.B09 Page 1 of 3
DMU-30ACV Series
Ruggedized True-rms ac Voltmeters with Daylight
Readable, Auto-Dimming LED Displays
TECHNICAL NOTES (continued)
Performance/Functional Specifications
Typical at TA = +25°C, 60Hz sine-wave input, unless otherwise noted.
4. Calibration: Periodic recalibration of DMU-30ACV voltmeters is
not required under most indoor operating environments. However,
units operating in environments subject to vibration and/or extreme
temperature variations should have their accuracy verified on a yearly
basis. If recalibration is necessary, it should only be performed by
qualified technical personnel. Calibration is performed with potentially
lethal voltages applied to the DMU-30ACV and its associated wiring.
A plastic, fully-insulated adjusting tool must be used to access the
recessed potentiometers located on the back of the unit (see Mechanical Specifications). Contact Murata / DATEL if additional information
is required regarding calibration, setup, or any other technical issue
pertaining to DMU-30ACV ac voltmeters.
5. Minimum-Intensity Adjustment Potentiometer: Users can adjust
the DMU-30ACV’s minimum LED display brightness to suit their indoor
viewing requirements by adjusting the ¾-turn, rear-mounted intensity
adjustment potentiometer. Please note, this potentiometer will have
minimal impact on display brightness in high ambient light environments.
The intensity adjustment potentiometer is factory preset to its midpoint position. As viewed from the rear of the meter, and with the
model number label facing up, turning the potentiometer clockwise
increases the LED display’s intensity. See the Mechanical Specifications section for potentiometer locations.
6. 2-Wire Operation: In indoor applications where daylight readability
(i.e., maximum display brightness) is not required, DMU-30ACV meters
will meet their specified accuracy with ac supply voltages (TB1) well
below 85Vac. While performance is not guaranteed, DMU-30ACV
voltmeters’ remain easily readable and accurate with ac supplies as
low as 20Vac in most indoor environments.
Please note, when operated indoors in a 2-wire mode (i.e., TB1 and
TB2 are connected to the same ac voltage), DMU-30ACV series’ input
current will increase as the input supply is decreased. At 20Vac, the
input supply current will be approximately 30mA.
Min.
Typ.
Max.
Units
DMU-30ACV-0
0
–
19.99
Vac
DMU-30ACV-1
0
–
199.9
Vac
Input (TB2)
Full Scale Input Range:
DMU-30ACV-2
Input-Voltage Frequency Range
0
–
300
Vac
47
60
1000
Hz
Performance
Sampling Rate
2.5 readings per second
Accuracy ➀
±0.4%FS ±2 counts w/ 60Hz
sine-wave input
Measurement Type
RMS responding, Crest Factors of 1-5
Zero Reading (within 30 sec.)
“–002”
“000”
“002”
Cnts
–
±0.2
±0.4
Cnts/°C
2000
–
–
Vdc
Temperature Drift (0 to +60°C)
Breakdown Voltage (TB1 to TB2)
Supply Voltage (TB1)
DMU-30ACV
85
–
264
Vac/4763Hz
DMU-30ACV (total darkness)
–
4
6
mA/4763Hz
DMU-30ACV (full sunlight)
–
40
50
mA/4763Hz
Supply Current (TB1) ➁
Terminal Block Wiring (TB1 & TB2)
Wire Size
16-22 AWG, Solid or stranded
Insulation Strip Length
0.250 inches (6.35)
Screw Tightening Torque
2.2 lb·in (0.25 N·m) ±20%
Rated Voltage
300Vac
Display
Display Type and Size
Daylight readable, auto-dimming,
3½ digit, 0.56"/14.2mm high red LED
Decimal Point
Fixed, model dependent
Overrange Indication
"1_ _ _ "
Physical/Environmental
Ordering Information
Model
DMU-30ACV-0-DR-C
DMU-30ACV-1-DR-C
DMU-30ACV-2-DR-C
Input Range
0 to 19.99Vac
0 to 199.9Vac
0 to 300Vac
Operating Temperature
–25
Storage Temperature
Humidity (non-condensing)
–
+60
°C
–40
–
+75
°C
0
–
85
%
Dimensions
See mechanical specifications
Weight
1.3 ounces (36 grams) nominal
➀ Specified accuracy applies to inputs with crest factors (CF) up to 2.0, where CF = Vpeak/
Vrms. Crest factors of 2-5 introduce an additional eror of ±3% of full scale. Voltmeters
are calibrated with near full-scale, 60Hz sine-wave input.
➁ Display reading is set to “1888”. Specified power supply currents are steady state; larger
surge currents can occur at initial application of ac power. Power supply input (TB1) set to
120Vac/60 Hz.
www.murata-ps.com/support
MPM_DMU-30ACV.B09 Page 2 of 3
DMU-30ACV Series
Ruggedized True-rms ac Voltmeters with Daylight
Readable, Auto-Dimming LED Displays
Mechanical Dimensions: Inches (mm)
Tolerances: 2 PL DEC ±0.02 (±0.51)
3 PL DEC ±0.010 (±0.254)
2.85
(72.39)
M3 INSERT
0.10 (2.54) DEPTH
1.5
(38.1)
1.60
(40.64)
CAL
BRIGHTNESS
ADJUST
1.97
(50.0)
0.26
(6.6)
1
2
1
TB1
PWR
SUPPLY
INPUT
FRONT VIEW
2
TB2
REAR VIEW
+ VIN –
SIGNAL
INPUT
RECOMMENDED DRILL AND PANEL CUTOUT
2.118
(53.8)
Note: The supplied M3 screws
and washers will accommodate
panel thicknesses from 0.060 to
0.090 inches (1.52 to 2.28 mm).
1.30
(33.02)
Tighten screws to 3.5–4.5 in-lbs
(0.4–0.5 Nm).
PANEL CUTOUT
0.136 (3.45) DIA
(6 REQUIRED)
0.878
(22.3)
INTERNAL CORNER RADII
0.032 (0.81) MAX.
1.26
(32.00)
2.52
(64.00)
PANEL INSTALLATION
Step 1.
Step 2.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Step 3.
Step 4.
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2013 Murata Power Solutions, Inc.
www.murata-ps.com/support