PA3655NL - Product finder

THT Current Sense Transformers
For Arc Fault Detection Circuits
Works with the TI SolarMagic RD-195 DC Arc Fault Detection
Reference Design Kit
For the TI SM73201-ARC-EV PCB
UL/C-UL recognized components
3000 Vrms gate to drive winding test
Useful operating frequency from 50 kHz to 500 kHz
Electrical Specifications @ 25°C — Operating Temperature -40°C to 130°C
Part Number
Turns Ratio
Primary Inductance
(3-7) (mH MIN)
(3-7) (Ω MAX)
(4-8) (mΩ MAX)
(1-10) (mΩ MAX)
(Pri-Sec) (Vrms)
PA3655NL
200:200:1
76
15.8
15.8
1.7
3000
Part Number
RT
(Ω)
PA3655NL
200
DCR Pri 1
DCR Sec
Electrical Specifications @ 25°C — Operating Temperature -40°C to 130°C
Reference Data
Ipk
Max Flux Density
(Amps)
(Gauss)
34
2000
Notes:
1. These current sense transformers have two one turn primaries that can be used in parallel. The listed current
ratings are for parallel connection.
2. The reference values are for an application using the termination resistor (Rt) and operating with unipolar
waveform at 100kHz, 40% duty cycle. The estimated temperature rise is 55°C.
3. The peak flux density should remain below 2100 Gauss to ensure that the core does not saturate. Use the following formula to calculate the peak flux density: Bpk = Kb * Ipk * Rt * don/(Ff * Freq. in kHz) where: Rt is the
terminating resistor in the application and Ff is 1 for unipolar waveform and 2 for bipolar waveform
.810 MAX
20,57
10
.350
8,89
.750
19,05 MAX
.700
17,78
17.12
7
.200
5,08
4
SUGGESTED PCB HOLE PATTERN
Weight.............................5 grams
Tray. . . . . . . . . . . . . . . . . . . . . . 2 0 /t ray
Dimensions:
4
Inches
mm
Unless otherwise specified, all tolerences are ±
7
10
Kb
(6X) .040
1
3
Calculation Data
Schematic
.580
14,73 MAX
1
Hi-Pot
4. The temperature rise of the component is calculated based on the total core loss and copper loss:
A. To calculate total copper loss (W): P(cu) = Ipk2 * DCR Sec * Ff * don where: Ff is 1 for unipolar waveform and
2 for bipolar waveform
B. To calculate total core loss (W): P(core) = 0.000073 * (Freq. in kHz)1.67 * (Bop in kG)2.532 where: Bop in kG =
Kb * Ipk * Rt * don/(2000 * Freq. in kHz)
C. To calculate temperature rise: Temperature Rise (C) = 60.18 * (Core Loss(W) + Copper Loss (W)).833
Mechanicals
PA3655NL
.130
3,30
DCR Pri 2
8
.010
0,25
For More Information
Pulse Worldwide
Headquarters
12220 World Trade Drive
San Diego, CA 92128
U.S.A.
Pulse Europe
Zeppelinstrasse 15
71083 Herrenberg
Germany
Pulse China Headquarters
Pulse North China
Pulse South Asia
Pulse North Asia
B402, Shenzhen Academy of
Room 2704/2705
135 Joo Seng Road
3F No. 198, Zhongyuan Road
Aerospace Technology Bldg.
Super Ocean Finance Ctr.
#03-02
Zhongli City
10th Kejinan Road
2067 Yan An Road West
PM Industrial Bldg.
Taoyuan County (32068)
High-Tech Zone
Shanghai 200336
Singapore 368363
Taiwan
Nanshan District
China
Shenzen, PR China 518057
Tel: 858 674 8100
Tel: 49 7032 7806 0
Tel: 86 755 33966678
Tel: 86 21 62787060
Tel: 65 6287 8998
Tel: 886 3 4356768
Fax: 858 674 8262
Fax: 49 7032 7806 12
Fax: 86 755 33966700
Fax: 86 2162786973
Fax: 65 6287 8998
Fax: 886 3 4356823
Performance warranty of products offered on this data sheet is limited to the parameters specified. Data is subject to change without notice. Other brand and product names mentioned herein may be
trademarks or registered trademarks of their respective owners. © Copyright, 2012. Pulse Electronics, Inc. All rights reserved.
1
pulseelectronics.com
P717.A (2/13)